Publications by authors named "Zannis Kostantinos"

Objectives: The goal of this study was to improve decision making regarding the transfusion of patients at the end of extracorporeal circulation for cardiac surgery through machine learning predictions of the evolution of platelets counts, prothrombin ratio, and fibrinogen assay.

Methods: Prospective data with information about patient preoperative biology and surgery characteristics were collected at Institut Mutualiste Montsouris Hospital (Paris, France) for 10 months (n = 598). For each outcome of interest, instead of arbitrarily choosing 1 machine learning algorithm, we trained and tested a variety of algorithms together with the super learning algorithm, a state-of-the-art ensemble method that aggregates all the predictions and selects the best performing algorithm (total, 137 algorithms).

View Article and Find Full Text PDF

Background: Concerns have been previously raised regarding the potential early degeneration of the Mitroflow (Sorin Group Italia, Saluggia, Vercelli, Italy) bioprostheses. We aimed to evaluate our clinical experience with the Mitroflow LXA prosthesis for aortic valve replacement.

Methods: We prospectively analyzed data from 227 consecutive patients (133 males, mean age 73.

View Article and Find Full Text PDF

Background: The present study was undertaken to evaluate clinical, hemodynamic, and morphologic results of composite stentless xenograft with polyethylene terephthalate fiber (Dacron; DuPont, Wilmington, DE) graft extension for combined replacement of the aortic valve, root, and ascending aorta.

Methods: Between 1997 and 2008, 55 consecutive patients (33 men, 71 +/- 11 years) underwent ascending aortic replacement using Medtronic Freestyle with Dacron graft extension (DuPont). Indications included aneurysm (n = 31, 56%), dissection (n = 16, 29%), and endocarditis (n = 8, 15%).

View Article and Find Full Text PDF

Increasing patient age and improved durability of latest generation bioprostheses have stimulated the use of bioprosthetic devices in the setting of ascending aortic replacement as an alternative to mechanical valved conduits or aortic valve-sparing procedures. We performed an English literature review to assess different surgical options that have been described for bioprosthetic replacement of the ascending aorta. Reported options include: (1) composite valved conduits using a stented bioprosthesis; (2) composite valved conduits using a stentless bioprosthesis; (3) total xenopericardial valved conduits.

View Article and Find Full Text PDF

Background: Heart transplantation in patients supported with ventricular assist devices (VADs) entails a high risk of injury at resternotomy. Prior femorofemoral bypass is the preferred approach in these patients, but poor venous drainage may restrict arterial flow rate.

Patients And Methods: We compared bypass parameters, transfusion requirements and postoperative outcome in 33 consecutive patients (40.

View Article and Find Full Text PDF