Publications by authors named "Zakharov P"

Objective: To conduct a systematic review of studies on various posterior pedicle screw fixation (PSF) methods used for treating neurologically intact thoracolumbar burst fractures and to identify the most effective and safe approaches.

Methods: We conducted a systematic review adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, with the study registered in PROSPERO (CRD42024531093). The inclusion criteria were: (1) publication dates from January 1, 2004, to December 31, 2023; (2) availability of full-text articles in English; (3) thoracolumbar burst fractures without neurological deficits; (4) patients aged over 18; (5) reports on treatment outcomes or complications; (6) a mean follow-up period of at least 12 months.

View Article and Find Full Text PDF

The pancreatic islet microenvironment is highly oxidative, rendering β cells vulnerable to autoinflammatory insults. Here, we examined the role of islet resident macrophages in the autoimmune attack that initiates type 1 diabetes. Islet macrophages highly expressed CXCL16, a chemokine and scavenger receptor for oxidized low-density lipoproteins (OxLDLs), regardless of autoimmune predisposition.

View Article and Find Full Text PDF

During development, inflammation or tissue injury, macrophages may successively engulf and process multiple apoptotic corpses via efferocytosis to achieve tissue homeostasis. How macrophages may rapidly adapt their transcription to achieve continuous corpse uptake is incompletely understood. Transcriptional pause/release is an evolutionarily conserved mechanism, in which RNA polymerase (Pol) II initiates transcription for 20-60 nucleotides, is paused for minutes to hours and is then released to make full-length mRNA.

View Article and Find Full Text PDF

Composite materials are gaining increasing attention from researchers worldwide due to their ability to offer tailored properties for various technical challenges. One of these promising fields is metal matrix composites, including carbon-reinforced metals and alloys. These materials allow for the reduction of density while simultaneously enhancing their functional properties.

View Article and Find Full Text PDF

We present a laser-speckle imaging technique, termed Echo speckle imaging (ESI), that quantifies the local dynamics in biological tissue and soft materials with a noise level around or below 10% of the measured signal without affecting the spatial resolution. We achieve this through an unconventional speckle beam illumination that creates changing, statistically independent illumination conditions and substantially increases the measurement accuracy. Control experiments for dynamically homogeneous and heterogeneous soft materials and tissue phantoms illustrate the performance of the method.

View Article and Find Full Text PDF

Autoimmune diabetes is one of the complications resulting from checkpoint blockade immunotherapy in cancer patients, yet the underlying mechanisms for such an adverse effect are not well understood. Leveraging the diabetes-susceptible nonobese diabetic (NOD) mouse model, we phenocopy the diabetes progression induced by programmed death 1 (PD-1)/PD-L1 blockade and identify a cascade of highly interdependent cellular interactions involving diabetogenic CD4 and CD8 T cells and macrophages. We demonstrate that exhausted CD8 T cells are the major cells that respond to PD-1 blockade producing high levels of IFN-γ.

View Article and Find Full Text PDF

Tissue-specific autoimmune diseases are driven by activation of diverse immune cells in the target organs. However, the molecular signatures of immune cell populations over time in an autoimmune process remain poorly defined. Using single-cell RNA sequencing, we performed an unbiased examination of diverse islet-infiltrating cells during autoimmune diabetes in the nonobese diabetic mouse.

View Article and Find Full Text PDF

Tissue-specific autoimmunity occurs when selected antigens presented by susceptible alleles of the major histocompatibility complex are recognized by T cells. However, the reason why certain specific self-antigens dominate the response and are indispensable for triggering autoreactivity is unclear. Spontaneous presentation of insulin is essential for initiating autoimmune type 1 diabetes in non-obese diabetic mice.

View Article and Find Full Text PDF

Background: Extensive past work showed that noninvasive continuous glucose monitoring with a wearable Multisensor device worn on the upper arm provides useful information about glucose trends to improve diabetes therapy in controlled and semicontrolled conditions.

Methods: To test previous findings also in uncontrolled in-clinic and outpatient conditions, a long-term study has been conducted to collect Multisensor and reference glucose data in a population of 20 type 1 diabetes subjects. A total of 1072 study days were collected and a fully on-line compatible algorithmic routine linking Multisensor data to glucose applied to estimate glucose trends noninvasively.

View Article and Find Full Text PDF

Background: Extensive past work showed that noninvasive continuous glucose monitoring with a wearable multisensor device worn on the upper arm provides useful information about glucose trends to improve diabetes therapy in controlled and semicontrolled conditions.

Method: To test previous findings also in uncontrolled conditions, a long term at home study has been organized to collect multisensor and reference glucose data in a population of 20 type 1 diabetes subjects. A total of 1072 study days were collected and a fully on-line compatible algorithmic routine linking multisensor data to glucose applied to estimate glucose levels noninvasively.

View Article and Find Full Text PDF

We examined the transcriptional profiles of macrophages that reside in the islets of Langerhans of 3-wk-old non-obese diabetic (NOD), NOD., and B6.g7 mice.

View Article and Find Full Text PDF

The non-ergodicity problem of temporal averaging in the laser speckle contrast imaging (LSCI) is discussed both theoretically and numerically. We demonstrate that temporal speckle statistics assessed within a finite time window might differ from the statistics of the speckle ensemble. The dependence of temporal speckle contrast on sample dynamics is non-monotonic and demonstrates regimes of negative (ergodic), as well as positive correlations with dynamics (non-ergodic).

View Article and Find Full Text PDF

Tubulin polymers, microtubules, can switch abruptly from the assembly to shortening. These infrequent transitions, termed "catastrophes", affect numerous cellular processes but the underlying mechanisms are elusive. We approached this complex stochastic system using advanced coarse-grained molecular dynamics modeling of tubulin-tubulin interactions.

View Article and Find Full Text PDF

Background: We study here the influence of different patients and the influence of different devices with the same patients on the signals and modeling of data from measurements from a noninvasive Multisensor glucose monitoring system in patients with type 1 diabetes. The Multisensor includes several sensors for biophysical monitoring of skin and underlying tissue integrated on a single substrate.

Method: Two Multisensors were worn simultaneously, 1 on the upper left and 1 on the upper right arm by 4 patients during 16 study visits.

View Article and Find Full Text PDF

The nonhuman primate model is suitable to study mechanisms of functional recovery following lesion of the cerebral cortex (motor cortex), on which therapeutic strategies can be tested. To interpret behavioral data (time course and extent of functional recovery), it is crucial to monitor the properties of the experimental cortical lesion, induced by infusion of the excitotoxin ibotenic acid. In two adult macaque monkeys, ibotenic acid infusions produced a restricted, permanent lesion of the motor cortex.

View Article and Find Full Text PDF

The Multisensor Glucose Monitoring System (MGMS) features non invasive sensors for dielectric characterisation of the skin and underlying tissue in a wide frequency range (1 kHz-100 MHz, 1 and 2 GHz) as well as optical characterisation. In this paper we describe the results of using an MGMS in a miniaturised housing with fully integrated sensors and battery. Six patients with Type I Diabetes Mellitus (age 44±16 y; BMI 24.

View Article and Find Full Text PDF

A wearable system incorporating sensors for dielectric and optical spectroscopy was used to study skin properties and their dependence on the cutaneous blood content (CBC). Simultaneous measurements with both modalities were carried out on the upper arm during blood perfusion-provoking exercises performed by four subjects in four separate sets of experiments. By relating changes in the attenuation of green (central wavelength λ(c) = 568 nm) and infrared (λ(c) = 798 nm) light, the ratio of mean pathlengths travelled by photons in the skin blood plexus was obtained.

View Article and Find Full Text PDF

We study the noise of the intensity variance and of the intensity correlation and structure functions measured in light scattering from a random medium in the case when these quantities are obtained by averaging over a finite number N of pixels of a digital camera. We show that the noise scales as 1/N in all cases and that it is sensitive to correlations of signals corresponding to adjacent pixels as well as to the effective time averaging (due to the finite integration time) and spatial averaging (due to the finite pixel size). Our results provide a guide to estimation of noise levels in such applications as multi-speckle dynamic light scattering, time-resolved correlation spectroscopy, speckle visibility spectroscopy, laser speckle imaging etc.

View Article and Find Full Text PDF

It is widely accepted that noninvasive glucose monitoring (NIGM) has the potential to revolutionize diabetes therapy. However, current approaches to NIGM studied to date have not yet demonstrated a level of acceptable functionality to allow real-time use, beyond restricted fields of application. A number of reviews have been devoted to the subject of NIGM with different focuses related to challenges and a description of the respective underlying problems.

View Article and Find Full Text PDF

Changes in morphology of the skin are an important factor that can affect non-invasive measurements performed through this organ, in particular for glucose monitoring in e.g. patients with diabetes mellitus.

View Article and Find Full Text PDF

An optical diffuse reflectance sensor for characterization of cutaneous blood content and optimized for continuous monitoring has been developed as part of a non-invasive multisensor system for glucose monitoring. A Monte Carlo simulation of the light propagation in the multilayered skin model has been performed in order to estimate the optimal geometrical separation of the light source and detector for skin and underlying tissue. We have observed that the pathlength within the upper vascular plexus of the skin which defines the sensor sensitivity initially grows with increasing source-detector distance (SDD) before reaching a maximum at 3.

View Article and Find Full Text PDF

Laser speckle imaging (LSI) based on the speckle contrast analysis is a simple and robust technique for imaging of heterogeneous dynamics. LSI finds frequent application for dynamical mapping of cerebral blood flow, as it features high spatial and temporal resolution. However, the quantitative interpretation of the acquired data is not straightforward for the common case of a speckle field formed by both by moving and localized scatterers such as blood cells and bone or tissue.

View Article and Find Full Text PDF

We have analyzed the image formation and dynamic properties in laser speckle imaging (LSI) both experimentally and with Monte Carlo simulation. We show for the case of a liquid inclusion that the spatial resolution and the signal itself are both significantly affected by scattering from the turbid environment. Multiple scattering leads to blurring of the dynamic inhomogeneity as detected by LSI.

View Article and Find Full Text PDF

We report the first observation of the impact of mesoscopic fluctuations on the photocount statistics of coherent light scattered in a random medium. A Poisson photocount distribution of the incident light widens and gains additional asymmetry upon transmission through a suspension of small dielectric spheres. The effect is only appreciable when the average number n of photocounts becomes comparable or larger than the effective dimensionless conductance g of the sample.

View Article and Find Full Text PDF

We introduce a charge-coupled device (CCD) camera-based detection scheme in dynamic light scattering that provides information on the single-scattered autocorrelation function even for fairly turbid samples. It is based on the single focused laser beam geometry combined with the selective cross-correlation analysis of the scattered light intensity. Using a CCD camera as a multispeckle detector, we show how spatial correlations in the intensity pattern can be linked to single- and multiple-scattering processes.

View Article and Find Full Text PDF