Brachytherapy utilizes a multitude of radioactive sources and treatment techniques that often exhibit widely different spatial and temporal dose delivery patterns. Biophysical models, capable of modeling the key interacting effects of dose delivery patterns with the underlying cellular processes of the irradiated tissues, can be a potentially useful tool for elucidating the radiobiological effects of complex brachytherapy dose delivery patterns and for comparing their relative clinical effectiveness. While the biophysical models have been used largely in research settings by experts, it has also been used increasingly by clinical medical physicists over the last two decades.
View Article and Find Full Text PDFPurpose: Our purpose was to describe the process and outcome of performing postimplantation dosimetric assessment and intraoperative dose correction during prostate brachytherapy using a novel image fusion-based treatment-planning program.
Methods And Materials: Twenty-six consecutive patients underwent intraoperative real-time corrections of their dose distributions at the end of their permanent seed interstitial procedures. After intraoperatively planned seeds were implanted and while the patient remained in the lithotomy position, a cone beam computed tomography scan was obtained to assess adequacy of the prescription dose coverage.
Purpose: Skin surface dosimetric discrepancies between measured and treatment planning system predicted values were traced to source position sag inside the applicator and to source transit time. We quantified their dosimetric impact and propose corrections for clinical use.
Methods And Materials: We measured the dose profiles from the Varian Leipzig-style high-dose-rate (HDR) skin applicator, using EBT3 film, photon diode, and optically stimulated luminescence dosimeter for three different GammaMedplus HDR afterloaders.
Purpose: To report the long-term control and toxicity outcomes of patients with clinically localized prostate cancer, who underwent low-dose-rate prostate brachytherapy with magnetic resonance spectroscopic image (MRSI)-directed dose escalation to intraprostatic regions.
Methods And Materials: Forty-seven consecutive patients between May 2000 and December 2003 were analyzed retrospectively. Each patient underwent a preprocedural MRSI, and MRS-positive voxels suspicious for malignancy were identified.
Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented.
Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z.
Purpose: Sterilization of surgical margins for lesions involving the dura is complicated by the tolerance of the spinal cord and/or cauda equina, especially in the setting of prior radiation therapy (RT); use of intraoperative brachytherapy may allow local delivery of therapeutic dose without damaging sensitive structures.
Methods And Materials: Patients with malignant lesions involving the dura received intraoperative brachytherapy with a (32)P plaque after maximal resection of the tumor. Local recurrence (LR) was analyzed using competing risks analysis; overall survival was analyzed using Kaplan-Meier statistics.
Phys Med Biol
November 2014
HDR BrachyView is a novel in-body dosimetric imaging system for real-time monitoring and verification of the source position in high dose rate (HDR) prostate brachytherapy treatment. It is based on a high-resolution pixelated detector array with a semi-cylindrical multi-pinhole tungsten collimator and is designed to fit inside a compact rectal probe, and is able to resolve the 3D position of the source with a maximum error of 1.5 mm.
View Article and Find Full Text PDFWe revisit a long-standing problem of optimization of fractionated radiotherapy and solve it in considerable generality under the following three assumptions only: (1) repopulation of clonogenic cancer cells between radiation exposures follows linear birth-and-death Markov process; (2) clonogenic cancer cells do not interact with each other; and (3) the dose response function s(D) is decreasing and logarithmically concave. Optimal schedules of fractionated radiation identified in this work can be described by the following 'greedy' principle: give the maximum possible dose as soon as possible. This means that upper bounds on the total dose and the dose per fraction reflecting limitations on the damage to normal tissue, along with a lower bound on the time between successive fractions of radiation, determine the optimal radiation schedules completely.
View Article and Find Full Text PDFThe probability of a cure in radiation therapy (RT)-viewed as the probability of eventual extinction of all cancer cells-is unobservable, and the only way to compute it is through modeling the dynamics of cancer cell population during and post-treatment. The conundrum at the heart of biophysical models aimed at such prospective calculations is the absence of information on the initial size of the subpopulation of clonogenic cancer cells (also called stem-like cancer cells), that largely determines the outcome of RT, both in an individual and population settings. Other relevant parameters (e.
View Article and Find Full Text PDFPurpose: A novel (32)P brachytherapy source has been in use at our institution intraoperatively for temporary radiation therapy of the spinal dura and other localized tumors. We describe the dosimetry and clinical implementation of the source.
Methods And Materials: Dosimetric evaluation for the source was done with a complete set of MCNP5 Monte Carlo calculations preceding clinical implementation.
Purpose: High dose rate (HDR) brachytherapy is a form of radiation therapy for treating prostate cancer whereby a high activity radiation source is moved between predefined positions inside applicators inserted within the treatment volume. Accurate positioning of the source is essential in delivering the desired dose to the target area while avoiding radiation injury to the surrounding tissue. In this paper, HDR BrachyView, a novel inbody dosimetric imaging system for real time monitoring and verification of the radioactive seed position in HDR prostate brachytherapy treatment is introduced.
View Article and Find Full Text PDFPurpose: The conformity of the achieved dose distribution to the treatment plan strongly correlates with the accuracy of seed implantation in a prostate brachytherapy treatment procedure. Incorrect seed placement leads to both short and long term complications, including urethral and rectal toxicity. The authors present BrachyView, a novel concept of a fast intraoperative treatment planning system, to provide real-time seed placement information based on in-body gamma camera data.
View Article and Find Full Text PDFObjective: To report long-term outcomes of men ≤60 years treated with brachytherapy (BT) for low- and intermediate-risk prostate cancer.
Patients And Methods: Of 1655 patients treated with BT for clinically localized prostate cancer between January 1998 and May 2008 at Memorial Sloan-Kettering Cancer Center, 236 patients with National Comprehensive Cancer Network low- (n = 178) or intermediate-risk (n = 58) prostate cancer were ≤60 years old with a 3-year minimum follow-up, and represent the subjects of this report. Brachytherapy was given either as monotherapy (n = 169) or with external beam radiation therapy (EBRT; n = 67).
Purpose: Advances in stereotactic radiosurgery have improved local control of spine metastases, but local failure is still a problem and repeat irradiation is limited by normal tissue tolerance. A novel high-dose-rate (HDR) brachytherapy technique has been developed to treat these previously irradiated lesions.
Methods And Materials: Five patients with progressive disease at previously irradiated sites in the spine who were not amenable to further external beam radiation were treated.
We introduce a novel mechanistic model of the yield of tissue damage at the end of radiation treatment and of the subsequent healing kinetics. We find explicit expressions for the total number of functional proliferating cells as well as doomed (functional but non-proliferating) cells as a function of time post treatment. This leads to the possibility of estimating-for any given cohort of patients undergoing radiation therapy-the probability distribution of those kinetic parameters (e.
View Article and Find Full Text PDFPurpose: Intraoperative radiation therapy (IORT) allows delivery of tumoricidal doses of radiation to areas of potential residual microscopic disease while minimizing doses to normal tissues. IORT using high-dose-rate (HDR) brachytherapy allows dose modulation and delivery of concomitant boosts to high-risk areas. This study describes a novel technique of HDR-IORT with dose painting (DP) (HDR-IORT-DP) and evaluates the clinical outcomes.
View Article and Find Full Text PDFBackground: Treatment of spinal and intracranial tumors with dural involvement is complicated by radiation tolerance of sensitive structures, especially in the setting of previous treatment.
Objective: To evaluate whether intraoperative brachytherapy with short-range sources allows therapeutic dose delivery without damaging sensitive structures.
Methods: The median doses of previous treatment were 3000 cGy (range, 1800-7200 cGy) for 8 patients with primary/recurrent and 17 patients with metastatic spinal tumors and 5040 cGy (range, 1300-6040 cGy) for 5 patients with locally recurrent and 2 patients with metastatic intracranial tumors.
Purpose: To report prostate-specific antigen (PSA) relapse-free survival and treatment-related toxicity outcomes after combining high-dose-rate (HDR) brachytherapy with external beam radiotherapy (EBRT) for patients with clinically localized prostate cancer.
Methods And Materials: Between 1998 and 2009, 229 patients were treated with HDR brachytherapy followed 3 weeks later by supplemental EBRT. The HDR brachytherapy boost consisted of three fractions of (192)Ir (5.
Purpose: To help establish patterns of care and standards of care of interstitial permanent low-dose-rate (LDR) and temporary high-dose-rate brachytherapy for prostate cancer and to compare the results with a similar 1998 American Brachytherapy Society (ABS) survey.
Methods And Materials: A comprehensive questionnaire intended to survey specific details of current clinical brachytherapy practice was provided to the participants of the seventh ABS Prostate Brachytherapy School. Responses were tabulated and descriptive statistics are reported.
Purpose: A well-established body of literature supports the use of high-dose-rate (HDR) brachytherapy as definitive treatment for localized prostate cancer. Most of the articles describe HDR as a boost with adjuvant external beam radiation, but there is a growing experience with HDR monotherapy.
Methods And Materials: The American Brachytherapy Society has convened a group of expert practitioners and physicists to develop guidelines for the use of HDR in the management of prostate cancer.
Purpose: To compare biochemical outcomes and morbidity associated with iodine-125 ((125)I) and palladium-103 ((103)Pd) brachytherapy as part of combined modality therapy for clinically localized prostate cancer.
Methods And Materials: Between October 2002 and December 2008, 259 patients underwent prostate brachytherapy ((125)I prescription dose, 110Gy: n=199; (103)Pd prescription dose, 100Gy: n=60) followed by external beam radiotherapy (median dose, 50.4Gy).
Purpose: To identify predictors of biochemical tumor control and present an updated prognostic nomogram for patients with clinically localized prostate cancer treated with brachytherapy.
Methods And Materials: One thousand four hundred sixty-six patients with clinically localized prostate cancer were treated with brachytherapy alone or along with supplemental conformal radiotherapy. Nine hundred one patients (61%) were treated with Iodine-125 ((125)I) monotherapy to a prescribed dose of 144Gy, and 41 (4.
Patients undergoing radiation therapy (and their physicians alike) are concerned with the probability of cure (long-term recurrence-free survival, meaning the absence of a detectable or symptomatic tumor). This is not what current practice categorizes as "tumor control (TC);" instead, TC is taken to mean the extinction of clonogenic tumor cells at the end of treatment, a sufficient but not necessary condition for cure. In this review, we argue that TC thus defined has significant deficiencies.
View Article and Find Full Text PDFRadiation in space generally produces higher dose rates than that on the Earth's surface, and contributions from primary galactic and solar events increase with altitude within the magnetosphere. Presently, no personnel monitor is available to astronauts for real-time monitoring of dose, radiation quality and regulatory risk. This group is developing a prototypic instrument for use in an unknown, time-varying radiation field.
View Article and Find Full Text PDFObjectives: To compare the long-term, prostate-specific antigen relapse-free survival outcome and incidence of toxicity for patients with low-risk prostate cancer who underwent brachytherapy or intensity-modulated radiotherapy (RT).
Methods: A total of 729 consecutive patients underwent brachytherapy (n = 448; prescription dose 144 Gy) or intensity-modulated RT alone (n = 281; prescription dose 81 Gy). The prostate-specific antigen relapse-free survival using the nadir plus 2 ng/mL definition and late toxicity using the National Cancer Institute's Common Terminology Criteria for Adverse Events were determined.