J Appl Clin Med Phys
December 2024
Purpose: Total skin electron therapy (TSET) is a complex radiotherapy technique, posing challenges in commissioning and quality assurance (QA), especially due to significant variability in patient body shapes. Previous studies have correlated dose with factors such as obesity index, height, and gender. However, current treatment planning systems cannot simulate TSET plans, necessitating heavy reliance on QA methods using standardized anthropomorphic phantoms and in-vivo dosimetry.
View Article and Find Full Text PDFObjective: The aim of this study was to summarize the literature on the applications of machine learning (ML) and their performance in Emergency Medical Services (EMS).
Methods: Four relevant electronic databases were searched (from inception through January 2024) for all original studies that employed EMS-guided ML algorithms to enhance the clinical and operational performance of EMS. Two reviewers screened the retrieved studies and extracted relevant data from the included studies.
Metal artifacts produce incorrect Hounsfield units and impact treatment planning accuracy. This work evaluates the use of single-energy metal artifact reduction (SEMAR) algorithm for treatment planning by comparison to manual artifact overriding. CT datasets of in-house 3D-printed spine and pelvic phantoms with and without metal insert(s) and two treated patients with metal implants were analysed.
View Article and Find Full Text PDFBackground: The CyberKnife Xsight lung-tracking system (XLTS) provides an alternative to fiducial-based target-tracking systems (FTTS) for non-small-cell lung cancer (NSCLC) patients without invasive fiducial insertion procedures. This study provides a method for 3D independent dosimetric verification of the accuracy of the FTTS compared to the XLTS without relying on log-files generated by the CyberKnife system.
Methods: A respiratory motion trace was taken from a 4D-CT of a real lung cancer patient and applied to a modified QUASAR™ respiratory motion phantom.
Introduction: In radiotherapy, the presence of air gaps near a tumour can lead to underdose to the tumour. In this study, the impact of air gaps on dose to the surface was evaluated. 3D-printing was used to construct a Eurosil-4 Pink bolus customised to the patient and its dosimetric properties were compared with that of Paraffin wax bolus.
View Article and Find Full Text PDFFor safe and accurate dose delivery in brachytherapy, associated equipment is subject to commissioning and ongoing quality assurance (QA). Many centres depend on the use of a well-type chamber ('well chamber') for performing brachytherapy dosimetry. Documentation of well chamber commissioning is scarce despite the important role the chamber plays in the whole brachytherapy QA process.
View Article and Find Full Text PDF