Objectives: Grain storage facility entrapments continue to be of concern in the agricultural industry, with nearly 1,500 documented incidents recorded over the last 45 years. Previous research studies have shown that attempting to extricate a full-size pulling test dummy from a grain mass requires a substantial amount of tensile or pull force - e.g.
View Article and Find Full Text PDFBackground: The way in which force increases in the anterolateral tissues and the lateral extra-articular tenodesis (LET) tissue to resist internal rotation (IR) of the tibia after anterior cruciate ligament (ACL) reconstruction in isolation and after LET augmentation, respectively, is not well understood.
Purpose: (1) To compare in a cadaveric model how force increases (ie, engages) in the anterolateral tissues with IR of the tibia after isolated ACL reconstruction and in the LET tissue after augmentation of the ACL reconstruction with LET and (2) to determine whether IR of the tibia is related to engagement of the LET tissue.
Study Design: Controlled laboratory study.
Arthroscopy of the wrist continues to evolve and advance as a valuable clinical technique in hand surgery. This article aims to address safety of wrist arthroscopy and provide an overview of the known iatrogenic complications. Ultimately, the likelihood of associated injuries during wrist arthroscopy is dependent on the surgeon's ability and understanding of the equipment.
View Article and Find Full Text PDFBackground: Propionibacterium is commonly recovered from explants or surrounding tissues in revision shoulder arthroplasty. Rather than attempting to differentiate a true infection from a false-positive result on the basis of the number of positive cultures, we characterized the amount of these bacteria in each specimen and shoulder.
Methods: The study included 137 revision shoulder arthroplasties from which a minimum of 4 specimens had been submitted for culture and at least 1 was positive for Propionibacterium.
Ulnar styloid impaction syndrome involves repetitive friction between an excessively long ulnar styloid and the carpus, resulting in chondromalacia, synovitis, and pain. The arthroscopic diagnosis, evaluation, and management of this syndrome are not well characterized. We present a patient with chronic wrist pain of unknown origin, culminating with arthroscopic findings demonstrating substantial loss of articular cartilage on both the lunate and triquetrum.
View Article and Find Full Text PDFClin Orthop Relat Res
September 2016
Background: Dorsal wrist ganglia (DWG) are a common, benign soft-tissue mass of the wrist. Excision of DWG is a common procedure performed by hand surgeons and may be performed using either open or arthroscopic techniques. This study aims to evaluate the frequency of stalk visualization with intralesional injection of inert dye in the course of arthroscopic excision along with incidence of recurrence with a minimum of 1-year follow-up.
View Article and Find Full Text PDFPurpose: To explore the incidence of failure of continuous peripheral nerve blockade (CPNB) after upper extremity operations.
Methods: Patient data regarding postoperative CPNB were retrospectively obtained from our institution's regional anesthesia database. Documented information on the first postoperative day included pain assessment ratings (numerical verbal pain scale, patient-reported breakthrough pain upon perceived return of sensation, appearance of the catheter site, complications, time of return of sensation, day of return of sensation, residual blockade, patient satisfaction with the block, and whether patient would receive the block again).
Background: Open reduction internal fixation (ORIF) of distal radius fractures via a volar approach involves surgical release of the overlying pronator quadratus (PQ) muscle. Complete repair of the PQ, defined as full and stable replacement of the periphery of the PQ back to its original anatomic location, is not always possible upon conclusion of the operation. Postoperative consequences of incomplete PQ repair with regards to range of motion (ROM), grip strength, and complications are not well documented.
View Article and Find Full Text PDFJ Hand Surg Am
August 2013
Purpose: To evaluate the outcomes of patients with ulnar impaction syndrome treated with a jig-facilitated, oblique, diaphyseal ulnar shortening osteotomy and fixed with a TriMed (Santa Clarita, CA) ulnar osteotomy compression plate.
Methods: A retrospective chart review of patients with ulnar impaction syndrome identified 38 patients who had had ulnar shortening osteotomy and fixation with the TriMed dynamic compression system. The following clinical data were obtained: patient age, sex, follow-up range of motion, grip strength, and complications.
Purpose: The purpose of this systematic review was to address the incidence of complications associated with wrist arthroscopy. Given the paucity of information published on this topic, an all-inclusive review of published wrist arthroscopy complications was sought.
Methods: Two independent reviewers performed a literature search using PubMed, Google Scholar, EBSCO, and Academic Megasearch using the terms "wrist arthroscopy complications," "complications of wrist arthroscopy," "wrist arthroscopy injury," and "wrist arthroscopy.
We demonstrate electrically addressable localized heating in fluid at the dielectric surface of silicon-on-insulator field-effect transistors via radio-frequency Joule heating of mobile ions in the Debye layer. Measurement of fluid temperatures in close vicinity to surfaces poses a challenge due to the localized nature of the temperature profile. To address this, we developed a localized thermometry technique based on the fluorescence decay rate of covalently attached fluorophores to extract the temperature within 2 nm of any oxide surface.
View Article and Find Full Text PDF