This article addresses the potential use of secondary polymer fibres in the field of structural concrete as a replacement for primary polymer fibres (mainly polypropylene/PP/), which are used in concrete to enhance its resistance when exposed to high temperatures (especially in the case of fire). Research has shown that, in addition to PP fibres, polyethylene terephthalate/PET/fibres, produced by recycling packaging materials (mainly PET bottles), can also be used as an alternative. These fibres are industrially produced in similar dimensions as PP fibres and exhibit similar behaviour when added to fresh and hardened concrete.
View Article and Find Full Text PDFPervious concrete (PCO) has many advantages and applications, such as water pooling reduction, noise attenuation, replenishment of groundwater reserves, etc. However, the use of pervious concrete is limited due to its low compressive strength and durability, especially as a result of portlandite leaching from concrete exposed to flowing water. The effects of active additives (nano SiO (NS) spent catalyst generated at the fluid catalytic cracking unit (FCCCw) and paper sludge waste burned at 700 °C (PSw)) along with particle size distribution of the coarse aggregate on the properties and durability of pervious concrete were determined in the research.
View Article and Find Full Text PDFThis article analyzes the integrated effect of industrial by-products (spent fluidized bed catalytic cracking catalyst waste (FCCCw) and paper sludge waste (PSw) generated in paper manufacturing) combined with nano-SiO (NS) on the properties of cement binder, when a certain part of the binder is replaced with the said by-products in the cement mix. Standard testing methods were used to analyze the physical and mechanical properties of cement-based materials. For structure analysis, we used X-ray diffraction (XRD), derivative thermogravimetry (DTG), mercury intrusion porosimetry (MIP) and scanning electron microscopy (SEM).
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
November 2020
Purpose: During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm cone-beam CT (CBCT) provides intraoperative 3D tomographic imaging which would allow for immediate verification and, if needed, revision.
View Article and Find Full Text PDFThe desire to photocontrol molecular properties ranging from materials to pharmacology using light as an external trigger with high spatiotemporal resolution led to the development of a broad range of photochromic scaffolds. Among them, azobenzenes are synthetically well accessible and show excellent fatigue resistance. Their photochromic properties vary with the substitution pattern and for different heteroarenes.
View Article and Find Full Text PDFIn optics, mode conversion is an elegant way to switch between Hermite Gaussian and Laguerre Gaussian beam profiles and thereby impart orbital angular momentum onto the beam and to create vortices. In optics such vortex beams can be produced in a setup consisting of two identical cylinder lenses. In electron optics, quadrupole lenses can be used for the same purpose.
View Article and Find Full Text PDFPurpose: To evaluate whether visual CT findings could account for the effect of current smoking.
Methods: 500 CT scans were visually evaluated within each lobe. A multivariate model for emphysema index was constructed containing previously described confounders in addition to the visual components associated with smoking status.
To identify a predictive value for the exacerbation status of chronic obstructive pulmonary disease (COPD) subjects, we evaluated the relationship between pulmonary vascular measurements on chest CT and severe COPD exacerbation.Six hundred three subjects enrolled in the COPDGene population were included and divided into nonexacerbator (n = 313) and severe exacerbator (n = 290) groups, based on whether they had an emergency room visit and/or hospitalization for COPD exacerbation. We measured the diameter of the main pulmonary artery (MPA) and ascending aorta (AA) at 2 different sites of the MPA (the tubular midportion and bifurcation) on both axial images and multiplanar reconstructions.
View Article and Find Full Text PDFObjective: To assess clinical feasibility of low-attenuation cluster analysis in evaluation of chronic obstructive pulmonary disease (COPD).
Materials And Methods: Subjects were 199 current and former cigarette smokers that underwent CT for quantification of COPD and had physiological measurements. Quantitative CT (QCT) measurements included low-attenuation area percent (LAA%) (voxels ≤ -950 Hounsfield unit [HU]), and two-dimensional (2D) and three-dimensional D values of cluster analysis at three different thresholds of CT value (-856, -910, and -950 HU).
Purpose: To correlate currently available quantitative CT measurements for airway disease with physiological indices and the body-mass index, airflow obstruction, dyspnea, and exercise capacity (BODE) index in patients with chronic obstructive pulmonary disease (COPD).
Materials And Methods: This study was approved by our institutional review board (IRB number 2778). Written informed consent was obtained from all subjects.
Atomic resolution in transmission electron microscopy of thin and light-atom materials requires a rigorous reduction of the beam energy to reduce knockon damage. However, at the same time, the chromatic aberration deteriorates the resolution of the TEM image dramatically. Within the framework of the SALVE project, we introduce a newly developed C_{c}/C_{s} corrector that is capable of correcting both the chromatic and the spherical aberration in the range of accelerating voltages from 20 to 80 kV.
View Article and Find Full Text PDFNatural deep eutectic solvents (DESs) dissolve simple metal oxides and are used as a reaction medium to synthesize spinel-type ferrite nanoparticles MFe2 O4 (M=Mg, Zn, Co, Ni). The best results for phase-pure spinel ferrites are obtained with the DES consisting of choline chloride (ChCl) and maleic acid. By employing DESs, the reactions proceed at much lower temperatures than usual for the respective solid-phase reactions of the metal oxides and at the same temperatures as synthesis with comparable calcination processes using metal salts.
View Article and Find Full Text PDFChronic myeloid leukemia (CML) therapy has markedly improved patient prognosis after introduction of imatinib mesylate for clinical use. However, a subset of patients develops resistance to imatinib and other tyrosine kinase inhibitors (TKIs), mainly due to point mutations in the region encoding the kinase domain of the fused BCR-ABL oncogene. To identify potential therapeutic targets in imatinib‑resistant CML cells, we derived imatinib-resistant CML-T1 human cell line clone (CML-T1/IR) by prolonged exposure to imatinib in growth media.
View Article and Find Full Text PDFBone marrow transplantation or ponatinib treatment are currently recommended strategies for management of patients with chronic myeloid leukemia (CML) harboring the T315I mutation and compound or polyclonal mutations. However, in some individual cases, these treatment scenarios cannot be applied. We used an alternative treatment strategy with interferon-α (IFN-α) given solo, sequentially or together with TKI in a group of 6 cases of high risk CML patients, assuming that the TKI-independent mechanism of action may lead to mutant clone repression.
View Article and Find Full Text PDFThe aim of this study was to compare the clinical, radiological and histological findings in a large population of subjects enrolled during a multicentre study of idiopathic pulmonary fibrosis, with a focus on discordance between imaging and histologic diagnoses of usual interstitial pneumonia (UIP).Two independent radiologists retrospectively reviewed 241 subjects who underwent high-resolution computed tomography (HRCT) and surgical lung biopsies. HRCT findings were classified as UIP, possible UIP and inconsistent with UIP.
View Article and Find Full Text PDFImportance: Central airway collapse greater than 50% of luminal area during exhalation (expiratory central airway collapse [ECAC]) is associated with cigarette smoking and chronic obstructive pulmonary disease (COPD). However, its prevalence and clinical significance are unknown.
Objective: To determine whether ECAC is associated with respiratory morbidity in smokers independent of underlying lung disease.
Purpose: The purposes of this study were to evaluate the effect of smoking status on quantitative computed tomography CT measures of low-attenuation areas (LAAs) on inspiratory and expiratory CT and to provide a method of adjusting for this effect.
Materials And Methods: A total of 6762 current and former smokers underwent spirometry and volumetric inspiratory and expiratory CT. Quantitative CT analysis was completed using open-source 3D Slicer software.
Objectives: To propose and evaluate a method to reduce variability in emphysema quantification among different computed tomography (CT) reconstructions by normalizing CT data reconstructed with varying kernels.
Methods: We included 369 subjects from the COPDGene study. For each subject, spirometry and a chest CT reconstructed with two kernels were obtained using two different scanners.
Purpose: To evaluate the relationships between DLCO, and Quantitative CT (QCT) measurements and visual assessment of pulmonary emphysema and to test the relative roles of visual and quantitative assessment of emphysema.
Materials And Methods: The subjects included 199 current and former cigarette smokers from the COPDGene cohort who underwent inspiratory and expiratory CT and also had diffusing capacity for carbon monoxide corrected for alveolar volume (DLCO/VA). Quantitative CT measurements included % low attenuation areas (%LAA-950ins=voxels ≤-950 Hounsfield unit (HU), %LAA-910ins, and %LAA-856ins), mean CT attenuation and 15th percentile HU value on inspiratory CT, and %LAA-856exp (voxels ≤-856 HU on expiratory CT).
Background: Early and late operations of the cleft lip represent exposure to general anesthesia during the first year of life. The early exposure to the anesthetics may influence long term neurological outcome. Timing of the operation may also influence the quality of life as babies with early repair might be accepted better by their families.
View Article and Find Full Text PDFThermal magnetic field noise from magnetic and non-magnetic conductive parts close to the electron beam recently has been identified as a reason for decoherence in high-resolution transmission electron microscopy (TEM). Here, we report about new experimental results from measurements for a layered structure of magnetic and non-magnetic materials. For a simplified version of this setup and other situations we derive semi-analytical models in order to predict the strength, bandwidth and spatial correlation of the noise fields.
View Article and Find Full Text PDFWithin the COPD Genetic Epidemiology (COPDGene) study population of cigarette smokers, 9% were found to be unclassifiable by the Global Initiative for chronic Obstructive Lung Disease (GOLD) criteria. This study was to identify the differences in computed tomography (CT) findings between this nonobstructed (GOLDU) group and a control group of smokers with normal lung function. This research was approved by the institutional review board of each institution.
View Article and Find Full Text PDFAim: To assess the impact of a hand hygiene protocol, using hand washing, alcohol hand rub and gloves when caring for preterm infants born after 31 weeks of gestation, on the incidence of neonatal late onset sepsis (LOS).
Methods: All babies delivered between 32 + 0 and 36 + 6 weeks gestation and admitted to the neonatal intensive care unit during a 14-month period were included. We followed a hand hygiene protocol with hand washing and alcohol hand rub (hand rub period) for the first 7 months and a protocol of hand washing, alcohol hand rub and gloves (gloves period) for the second 7 months.
Objective: This study evaluates the relationships between quantitative CT (QCT) and spirometric measurements of disease severity in cigarette smokers with and without chronic obstructive pulmonary disease (COPD).
Materials And Methods: Inspiratory and expiratory CT scans of 4062 subjects in the Genetic Epidemiology of COPD (COPDGene) Study were evaluated. Measures examined included emphysema, defined as the percentage of low-attenuation areas≤-950 HU on inspiratory CT, which we refer to as "LAA-950I"; air trapping, defined as the percentage of low-attenuation areas≤-856 HU on expiratory CT, which we refer to as "LAA-856E"; and the inner diameter, inner and outer areas, wall area, airway wall thickness, and square root of the wall area of a hypothetical airway of 10-mm internal perimeter of segmental and subsegmental airways.
The resolving power of an electron microscope is determined by the optics and the stability of the instrument. Recently, progress has been obtained towards subångström resolution at beam energies of 80 kV and below but a discrepancy between the expected and achieved instrumental information limit has been observed. Here we show that magnetic field noise from thermally driven currents in the conductive parts of the instrument is the root cause for this hitherto unexplained decoherence phenomenon.
View Article and Find Full Text PDF