Elderly patients often have more than one disease that affects walking behavior. An objective tool to identify which disease is the main cause of functional limitations may aid clinical decision making. Therefore, we investigated whether gait patterns could be used to identify degenerative diseases using machine learning.
View Article and Find Full Text PDFBackground: The impact of the nail radius of curvature, as one of the most important design features in modern femoral nails on the ease of nail removal, remains unknown. Therefore, the aim of this study was to investigate force, energy, and nail deformation of different nail designs.
Methods: Nail insertion and extraction was performed on six pairs of fresh-frozen human cadaveric femora on a material testing machine with two different nail systems - Trochanter femoral nail ADVANCED™ Nailing System with a radius of curvature of 1.
Intramedullary femoral nails provide an ideal mechanical axis for periprosthetic fracture fixation. Slotted nails allow a connection to a total knee arthroplasty (TKA) stem. This study aims to compare implant and construct stiffness, interfragmentary movement and cycles to failure between an antegrade slotted femoral nail construct docked to a TKA stem and a distal femoral locking plate in a human periprosthetic femoral fracture model.
View Article and Find Full Text PDFSkills training is important in an arthroplasty curriculum and can focus either on "part tasks" or on full procedures. The most commonly used simulations in orthopedics including arthroplasty are anatomic specimens, dry bone models, and virtual or other technology-enhanced systems. A course curriculum planning committee must identify the gaps to address, define what learners need to be able to do, and select the most appropriate simulation modality and assessment for delivery.
View Article and Find Full Text PDFSurgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation.
View Article and Find Full Text PDFIntroduction: Traumatic spinal injury presents the potential for significant morbidity and mortality, and posterior fixation and fusion with bone grafts is a primary treatment for many vertebral fractures. While iliac crest autograft (ICBG) is considered the gold standard in bone grafting, this carries risks of morbidity at the donor site as well as prolonging surgery time. Bone graft substitutes (BGS) may provide a viable alternative to autograft but there is little published data concerning its use in trauma.
View Article and Find Full Text PDFBackground: Cerclage wire is the current standard for circumferential bone fixation. Advances in technology have improved modern sutures, allowing for expanded utility and broader application. The present study compared the strength and durability of cerclage fixation between modern suture materials and monofilament wire.
View Article and Find Full Text PDFBackground: Although reported results on short stems sound very promising, the occurrence of distal femoral cortical hypertrophy is often observed. The aim of the present study was to report 5-year survival data of a commercially available trochanter sparing short stem and investigate the clinical impact of distal femoral cortical hypertrophy on the outcome.
Methods: 123 total hip arthroplasties were performed on 120 patients from April 2008 to May 2010 (mean age 62, range 29-89 years; 71 hips from male patients, 58%).
Introduction: Medial parapatellar or transpatellar ligament approaches are commonly used for nail osteosynthesis in tibia shaft fractures. The lower leg is normally in a hanging position to allow guide wire insertion and reaming of the tibia. However, this position complicates fracture reduction and retention, as well as image intensification throughout the procedure.
View Article and Find Full Text PDFBackground: Conservative treatment of even severe thoracic trauma including flail chest was traditionally the standard of care. Recently, we reported possible benefits of surgical chest wall stabilization in accordance with other groups. The aim of this study was to critically review our indications and results of internal fixation of rib fractures in the long-term course.
View Article and Find Full Text PDFRoutine implant removal is frequently performed although evidence-based guidelines are lacking. But routinely planned implant removal has significant economic implications and shows considerable complication rates. In general, clinical outcome seems to improve but pain relief after operation is often unpredictable.
View Article and Find Full Text PDFFracture-related infection (FRI) is one of the most challenging complications in orthopaedic trauma surgery. It has severe consequences for patients and an important socio-economic impact. FRI has distinct properties and needs to be addressed interdisciplinary.
View Article and Find Full Text PDFPurpose: The purpose of this study is to analyze the results using the USS fracture MIS system (DePuy Synthes) to treat instable pelvic ring fractures. As its outstanding feature, it is the only Schanz screw and rod system at present that combines angular stability, perforation/fenestration of the screws for cement-augmentation, a variable screw length, and a large screw diameter.
Materials And Methods: Retrospective investigation of 134 pelvic ring fractures treated in 2012-2013.
Background: Bone metastases and lytic lesions due to multiple myeloma are common in advanced cancer and can lead to debilitating complications (skeletal-related events [SREs]), including requirement for radiation to bone. Despite the high frequency of radiation to bone in patients with metastatic bone disease, our knowledge of associated healthcare resource utilization (HRU) is limited.
Methods: This retrospective study estimated HRU following radiation to bone in Austria, the Czech Republic, Finland, Greece, Poland, Portugal, Sweden and Switzerland.
With increasing life expectancy, fragility fractures of the pelvic ring are seen more frequently. Although their osteosynthesis can be very challenging, specific biomechanical studies for investigation of the fixation stability are still lacking. The aim of this study was to biomechanically evaluate four different fixation methods for sacrum Denis type II fractures in osteoporotic bone.
View Article and Find Full Text PDFIntroduction: Anatomic fit of intramedullary nails was suggested by previous studies to improve significantly when the nail radius of curvature (ROC) is closer to the average femoral anatomy. However, no attempt has been made to investigate the impact of different ROC designs on the nail insertion process. Therefore, this biomechanical study quantitatively compared the ease of insertion between femoral intramedullary nails with a 1.
View Article and Find Full Text PDFBackground: Skeletal-related events (SREs; pathologic fracture [PF], spinal cord compression and radiation or surgery to bone) are common complications of bone metastases or bone lesions and can impose a considerable burden on patients and healthcare systems. In this study, the healthcare resource utilisation (HRU) associated with PFs in patients with bone metastases or lesions secondary to solid tumours or multiple myeloma was estimated in eight European countries.
Methods: Eligible patients were identified in Austria, the Czech Republic, Finland, Greece, Poland, Portugal, Sweden and Switzerland.
Background: Dynamic augmentation of anterior cruciate ligament tears seems to reduce anteroposterior knee translation close to the pre-injury level. The aim of the present study is to biomechanically investigate the course of translation during a simulated early post-operative phase. It is hypothesized that anteroposterior translation is maintained at the immediate post-operative level over a simulated rehabilitation period of 50'000 gait cycles.
View Article and Find Full Text PDFIntroduction: Osteosynthesis of anterior pubic ramus fractures can be challenging, especially in poor bone quality. The aim of the present study was to compare plate and retrograde endomedullary screw fixation of the superior pubic ramus with low bone mineral density (BMD).
Materials And Methods: Twelve human cadaveric hemi-pelvises were analyzed in a matched pair study design.
Background: Operative treatment is the standard for severely displaced proximal humerus fractures, but functional impairment can persist. Retaining of the implant can be a reason and in other fracture situations has proved to ameliorate patient satisfaction. The aim of this study was to analyse the functional outcome after locking plate removal in proximal humerus fractures.
View Article and Find Full Text PDFIntroduction: Uncemented short, curved femoral stems may help save proximal bone stock during total hip arthroplasty (THA) and facilitate insertion in minimal invasive surgery. The aim of this 2 year, prospective, single-center study was to examine the stability and migration of the Fitmore (®) stem in THA using model-based radiostereometric analysis (RSA), and thus predict the implant's long-term survival. In addition, we evaluated the stem's clinical performance using standard clinical measures.
View Article and Find Full Text PDFBackground: Bone complications, also known as skeletal-related events (SREs), are common in patients with bone metastases secondary to advanced cancers.
Objective: To provide a detailed estimate of the health resource utilization (HRU) burden associated with SREs across eight European countries.
Methods: Eligible patients from centers in Austria, the Czech Republic, Finland, Greece, Poland, Portugal, Sweden, and Switzerland with bone metastases or lesions secondary to breast cancer, prostate, or lung cancer or multiple myeloma who had experienced at least one SRE (defined as radiation to bone, long-bone pathologic fracture, other bone pathologic fracture, surgery to bone or spinal cord compression) were entered into this study.
Introduction: Delayed bone healing is an eminent problem in the operative treatment of distal tibia fractures. To address this problem from a biomechanical perspective, the DLS 3.7 (Dynamic Locking Screw 3.
View Article and Find Full Text PDF