Publications by authors named "Yuya Shirakawa"

Quantitative values of positron emission tomography (PET) images using non-local-mean in a silicon photomultiplier (SiPM)-PET/computed tomography (CT) system with phantom and clinical images. The evaluation was conducted on a National Electrical Manufacturers Association body phantom with micro-spheres (4, 5, 6, 8, 10, 13 mm) and clinical images using the SiPM-PET/CT system. The signal-to-background ratio of the phantom was set to 4, and all PET image data was obtained and reconstructed using three-dimensional ordered subset expectation maximization, time-of-flight, point-spread function, and a 4-mm Gaussian filter (GF) and clear adaptive low-noise method (CaLM) in mild, standard, and strong intensities.

View Article and Find Full Text PDF

Objectives: To apply image registration in the follow up of lung nodules and verify the feasibility of automatic tracking of lung nodules using an artificial intelligence (AI) method.

Methods: For this retrospective, observational study, patients with pulmonary nodules 5-30 mm in diameter on computed tomography (CT) and who had at least six months follow-up were identified. Two radiologists defined a 'correct' cuboid circumscribing each nodule which was used to judge the success/failure of nodule tracking.

View Article and Find Full Text PDF

We evaluate the effects of list-mode reconstruction and the image-space point spread function (iPSF) on the contrast and quantitative values of positron emission tomography (PET) images using a SiPM-PET/CT system. The evaluation is conducted on an NEMA body phantom and clinical images using a Cartesion Prime SiPM-PET/CT system. The signal-to-background ratio (SBR) of the phantom is set to 2, 4, 6, and 8, and all the PET image data are obtained and reconstructed using 3D-OSEM, time-of-flight, iPSF (-/ +), and a 4-mm Gaussian filter with several iterations.

View Article and Find Full Text PDF

This paper presents a time-of-flight image sensor based on 8-Tap P-N junction demodulator (PND) pixels, which is designed for hybrid-type short-pulse (SP)-based ToF measurements under strong ambient light. The 8-tap demodulator implemented with multiple p-n junctions used for modulating the electric potential to transfer photoelectrons to eight charge-sensing nodes and charge drains has an advantage of high-speed demodulation in large photosensitive areas. The ToF image sensor implemented using 0.

View Article and Find Full Text PDF

Background: Lung cancer is the leading cause of cancer-related deaths throughout the world. Chest computed tomography (CT) is now widely used in the screening and diagnosis of lung cancer due to its effectiveness. Radiologists must identify each small nodule shadow from 3D volume images, which is very burdensome and often results in missed nodules.

View Article and Find Full Text PDF

An 8-tap CMOS lock-in pixel image sensor that has seven carrier-capturing and a draining time window was developed for short-pulse time-of-flight (TOF) measurements. The proposed pixel for the short-pulse TOF measurements has seven consecutive time-gating windows, each of which has the width of 6 ns, which is advantageous for high-resolution range imaging, particularly for relatively longer distances (>5 m) and under high ambient light operations. In order to enhance the depth resolution, a technique for the depth-adaptive time-gating-number assignment (DATA) for the short-pulse TOF measurement is proposed.

View Article and Find Full Text PDF

This study aims to establish optimal scan parameters by high temporal resolution computed tomography (CT) scan for emergency patients who cannot hold their breath. First, we investigated scan parameters that can reduce the effect of motion by evaluating motion artifacts from the moving phantom scan and the temporal sensitivity profile (TPS) measurement. Second, we confirmed the standard deviation (SD) of the CT values as well as the operating time and exposure dose.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session0k2u62j2bumv3imqhoohmhj6bqvg4hhe): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once