Objective: We previously established a separation method for five lipoprotein classes (HDL, LDL, IDL, VLDL and chylomicrons) in human serum by using anion-exchange high-performance liquid chromatography (AEX-HPLC). It was thought that analyzing of the subfractions of HDL or LDL is important for study of the atherogenic lipoproteins in atherosclerotic diseases, because a large number of studies were reported regarding them. Therefore, we estimated a separation mode of AEX-HPLC for analyzing cholesterol levels of two HDL-subfractions and two LDL-subfractions.
View Article and Find Full Text PDFBackground: Increased triglyceride (TG)-rich lipoproteins and decreased HDL that are implicated in the progression of atherosclerotic vascular diseases, are present in serum samples of patients undergoing haemodialysis (HD) therapy. Therefore, it is important to measure serum TG-rich lipoprotein concentrations to prevent the diseases.
Methods: The cholesterol concentrations of lipoprotein classes in serum samples from the HD patients (n = 18) and healthy subjects (n = 18) were analysed by our recently developed method of high-performance liquid chromatography (HPLC), in which the lipoprotein classes were separated using an anion-exchange column, and the cholesterol concentrations of each of those were measured enzymatically using a post-column reaction.
Background: Increased serum remnant lipoproteins are supposed to predict cardiovascular disease in addition to increased LDL. A new homogenous assay for remnant lipoprotein-cholesterol (RemL-C) has been developed as an alternative to remnant-like particle-cholesterol (RLP-C), an immunoseparation assay, widely used for the measurement of remnant lipoprotein cholesterol.
Methods: We evaluated the correlations and data validation between the 2 assays in 83 subjects (49 men and 34 women) without diabetes, hypertension and medications for hyperlipidemia, diabetes, and hypertension, and investigated the characteristics of remnant lipoproteins obtained by the two methods (RLP-C and RemL-C) and their relationships with IDL-cholesterol determined by our developed HPLC method.
Objectives: A convenient method based on anion-exchange HPLC was recently developed to determine cholesterol levels of lipoproteins (HDL, LDL, IDL, VLDL, and chylomicron). The present study was performed to compare this HPLC method to homogenous assay in regard to measurement accuracy of HDL and LDL cholesterol.
Design And Methods: Serum samples (n=105), including three samples from cholestasis patients, were measured by homogenous assay with Cholestest-LDL and CholestestN-HDL (Daiichi Chemicals, Tokyo) and by HPLC as reported previously (J Lipid Res 2003; 44: 1404-12).
We report a case of metachronous bilateral adrenal metastases from mucinous adenocarcinoma of the stomach. A 68-year-old man who had undergone surgery for advanced gastric cancer 5 months earlier had a follow-up computed tomography (CT) scan, which showed a right adrenal tumor. We performed a right adrenalectomy, and histopathological examination revealed a mucinous adenocarcinoma with features consistent with those of gastric cancer.
View Article and Find Full Text PDFIt is very important for immunotherapy to release Th2-dominated immunological conditions in patients with malignant diseases. In the present study, we assessed the intracellular cytokine profiles of CD4 positive cells in peripheral blood in patients with colorectal cancer using a flow cytometric analysis and we investigated whether Th2-dominated immunological conditions could be released by PSK. Peripheral blood samples were collected preoperatively from 57 patients with colorectal cancer before and after the oral administration of PSK (3g/day x 1 week).
View Article and Find Full Text PDFCentromere protein C (CENP-C) is a component of the kinetochore essential for correct segregation of sister chromatids in mammals. In Arabidopsis thaliana, a single-copy gene encoding a protein homologous to CENP-C has been found by homology in the whole-genome sequence. To investigate the CENP-C homolog (AtCENP-C), we cloned cDNAs by RT-PCR and determined its full-length coding sequence.
View Article and Find Full Text PDFThe simultaneous ion-exclusion/cation-exchange separation column packed with a polymethacrylate-based weakly acidic cation-exchange resin of 3 microm particle size was used to achieve the simultaneous high-speed separation of anions and cations (Cl(-), NO3(-), SO4(2-), Na(+), K(+), NH4(+), Ca(2+) and Mg(2+)) commonly found in environmental samples. The high-speed simultaneous separation is based on a combination of the ion-exclusion mechanism for the anions and the cation-exchange mechanism for cations. The complete separation of the anions and cations was achieved in 5 min by elution with 15 mM tartaric acid-2.
View Article and Find Full Text PDFThis paper describes an ion-exclusion chromatographic system for the rapid and selective determination of ammonium ion. The optimized ion-exclusion chromatographic system was established with a polymethacrylate-based weakly basic anion-exchange resin column (TSKgel DEAE-5PW) as the separation column, an aqueous solution containing 0.05 mM tetramethylammonium hydroxide (pH 9.
View Article and Find Full Text PDFIon chromatography (IC) has been a powerful tool for measuring ionic species in environmental samples such as tap, river and drain waters. Suppressor modules (membrane and disposable column types) have been used for reducing the background of a baseline. A new type of suppressor device, which has a suppressor resin and switching valve was developed.
View Article and Find Full Text PDF