The aim of this study was to investigate planning target volume (PTV) margin in online adaptive radiation therapy (oART) for gastric mucosa-associated lymphoid tissue (MALT) lymphomas. Four consecutive patients with gastric MALT lymphoma who received oART (30 Gy in 15 fractions) on the oART system were included in this study. One hundred and twenty cone-beam computed tomography (CBCT) scans acquired pre- and post-treatment of 60 fractions for all patients were used to evaluate intra- and interfractional motions.
View Article and Find Full Text PDFRationale And Objectives: Dual-energy subtraction (DES) imaging constitutes a technique that has demonstrated efficacy in enhancing the detectability of pulmonary nodules on chest radiographs. However, a simple and quantitative methodology for evaluating the clinical image quality of DES images is currently lacking. The objective of this study was to investigate the applicability of contrast-detail (C-D) phantom analysis to the visual clinical image quality evaluation of chest DES images.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
May 2023
Purpose: To investigate fundamental dosimetric properties of surface dose, exit dose, and beam profile of the brass mesh bolus for 4, 6, and 10 MV high-energy photon beams in radiation therapy.
Methods: Surface dose and exit dose in the water-equivalent phantom were measured, and percent depth doses (PDDs) were calculated with no bolus, one layer of brass mesh, two layers of brass mesh bolus, three layers of brass mesh bolus, and 0.5 cm tissue-equivalent (TE) bolus.
Objectives: This study aimed to quantitatively examine the effect of digital image processing of digital intraoral radiographic images on the resolution characteristics of the output image using a task transfer function (TTF).
Methods: A photostimulable phosphor system with three types of image processing filters, including periodontal, endodontic, and dentine-to-enamel junction filters, was used. Each filter can be used in conjunction with the sharpness filter (+ S).
Purpose: Recently developed and commercialized dual-layer flat panel detectors (DL-FPDs) with two indirect scintillators are capable of acquiring dual-energy X-ray images. However, in clinical practice, they are utilized to perform conventional radiography using diagnostic X-rays with a wide energy spectrum. The two layers of the DL-FPD may affect the obtained image quality, even when only using one layer for conventional image acquisition, and these effects are yet to be substantiated.
View Article and Find Full Text PDFThe objective of this study was to investigate the effects of (i) the difference in the beam qualities on the presampled modulation transfer function (MTF) using the edge method and (ii) the readout direction of the edge profile for the photostimulable phosphor (PSP) system. The International Electrotechnical Commission (IEC) defined a technique using the "radiation qualities based on a phantom made up of an aluminum added filter" (RQA). A general radiographic system with a tube voltage of 50 kV and 9.
View Article and Find Full Text PDFThis study aims to quantitatively evaluate the effect of additional copper-filters (Cu-filters) on the radiation dose and contrast-to-noise ratio (CNR) in a dental cone beam computed tomography (CBCT). The Cu-filter thickness and tube voltage of the CBCT unit were varied in the range of 0.00-0.
View Article and Find Full Text PDFObjectives: To quantify and validate the effect of pixel size on a digital intraoral radiographic system according to International Electrotechnical Commission standards through physical and visual evaluations.
Methods: The digital intraoral radiographic system used was the photostimulable phosphor imaging plate and scanner system. The system had three image capture modes: high-speed (HS), high-resolution (HR), and super high-resolution (SHR) with different pixels.
Purpose: The aim of this study was to account for interfractional clinical target volume (CTV) shape variation and apply this to the planning target volume (PTV) margin for prostate cancer radiation treatment plans.
Methods: Interfractional CTV shape variations were estimated from weekly cone-beam computed tomography (CBCT) images using statistical point distribution models. The interfractional CTV shape variation was taken into account in the van Herk's margin formula.
Purpose: To analyze the uncertainties of the rectum due to anisotropic shape variations by using a statistical point distribution model (PDM).
Materials And Methods: The PDM was applied to the rectum contours that were delineated on planning computed tomography (CT) and cone-beam CT (CBCT) at 80 fractions of 11 patients. The standard deviations (SDs) of systematic and random errors of the shape variations of the whole rectum and the region in which the rectum overlapped with the PTV (ROP regions) were derived from the PDMs at all fractions of each patient.
Purpose: The setup errors and organ motion errors pertaining to clinical target volume (CTV) have been considered as two major causes of uncertainties in the determination of the CTV-to-planning target volume (PTV) margins for prostate cancer radiation treatment planning. We based our study on the assumption that interfractional target shape variations are not negligible as another source of uncertainty for the determination of precise CTV-to-PTV margins. Thus, we investigated the interfractional shape variations of CTVs based on a point distribution model (PDM) for prostate cancer radiation therapy.