: Optical coherence tomography (OCT) is a leading ocular imaging modality, known for delivering high-resolution volumetric morphological images. However, conventional OCT systems are limited by their narrow field-of-view (FOV) and their reliance on scattering contrast, lacking molecular specificity. : To address these limitations, we developed a custom-built 105 ultra-widefield polarization-diversity OCT (UWF PD-OCT) system for assessing various retinal and choroidal conditions, which is particularly advantageous for visualizing peripheral retinal abnormalities.
View Article and Find Full Text PDFSignificance: Optical coherence tomography (OCT) has emerged as the standard of care for diagnosing and monitoring the treatment of various ocular disorders due to its noninvasive nature and volumetric acquisition capability. Despite its widespread applications in ophthalmology, motion artifacts remain a challenge in OCT imaging, adversely impacting image quality. While several multivolume registration algorithms have been developed to address this issue, they are often designed to cater to one specific OCT system or acquisition protocol.
View Article and Find Full Text PDFFractional-pixel CO laser therapy shows promise for treating the genitourinary syndrome of menopause (GSM). Nevertheless, it remains controversial in the field of female pelvic medicine. This is due to the inherent difficulties in obtaining noninvasive biopsies to evaluate the treatment's efficacy and safety objectively.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
November 2023
Purpose: The purpose of this study was to demonstrate the utility of polarization-diversity optical coherence tomography (PD-OCT), a noninvasive imaging technique with melanin-specific contrast, in the quantitative and qualitative assessment of choroidal nevi.
Methods: Nevi were imaged with a custom-built 55-degree field-of-view (FOV) 400 kHz PD-OCT system. Imaging features on PD-OCT were compared to those on fundus photography, auto-fluorescence, ultrasound, and non-PD-OCT images.
Quant Imaging Med Surg
April 2023
Background: The coordination and the directional order of ciliary metachronal waves are the major factors that determine the effectiveness of mucociliary clearance (MCC). Even though metachronal waves play an essential part in immune response, clinical diagnostic tools and imaging techniques that can reliably and efficiently capture their spatial distribution and function are currently limited.
Methods: We present label-free high-speed visualization of ciliary metachronal wave propagations in freshly-excised tracheal explants using a spectrally-encoded interferometric microscope over a two-dimensional (2D) plane of 0.
The addition of fruit juice may improve the physicochemical and functional characteristics of dairy products. The study evaluated the effect of 1−6% (v/v) blue honeysuckle juice (BHJ) on the physicochemical, sensory and antioxidant characteristics of fermented goat milk (FGM) during 21 days of refrigerated storage and in vitro gastrointestinal digestion. The incorporation of BHJ significantly increased (p < 0.
View Article and Find Full Text PDFA fast and practical computational cross-calibration of multiple spectrometers is described. A signal correlation matrix (CM) can be constructed from paired B-scans in a multiple-spectrometer optical coherence tomography (OCT), where the wavelength-corresponding pixels are indicated by high cross correlation. The CM can be used to either guide the physical alignment of spectrometers or to numerically match the spectra in the post-process.
View Article and Find Full Text PDFGenitourinary syndrome of menopause (GSM) negatively affects more than half of postmenopausal women. Energy-based therapy has been explored as a minimally invasive treatment for GSM; however, its mechanism of action and efficacy is controversial. Here, we report on a pilot imaging study conducted on a small group of menopause patients undergoing laser treatment.
View Article and Find Full Text PDFBiomed Opt Express
March 2022
The present paper introduces a numerical calibration method for the easy and practical implementation of multiple spectrometer-based spectral-domain optical coherence tomography (SD-OCT) systems. To address the limitations of the traditional hardware-based spectrometer alignment across more than one spectrometer, we applied a numerical spectral calibration algorithm where the pixels corresponding to the same wavelength in each unit are identified through spatial- and frequency-domain interferometric signatures of a mirror sample. The utility of dual spectrometer-based SD-OCT imaging is demonstrated through retinal imaging at two different operation modes with high-speed and dual balanced acquisitions, respectively, in which the spectral alignment is critical to achieve improved retinal image data without any artifacts caused by misalignment of the spectrometers.
View Article and Find Full Text PDFBackground: Soybean oil bodies (SOB) are naturally pre-emulsified lipid droplets recovered directly from soybean seeds. Almost all food emulsions contain salts. However, it was not clear how the incorporation of salts affected the physicochemical stability of SOB.
View Article and Find Full Text PDFMegahertz-rate optical coherence tomography angiography (OCTA) is highly anticipated as an ultrafast imaging tool in clinical settings. However, shot-noise-limited sensitivity is inevitably reduced in high-speed imaging systems. In this Letter, we present a coherent buffer averaging technique for use with a Fourier-domain mode-locked (FDML) laser to improve OCTA contrast at 1060 nm MHz-rate retinal imaging.
View Article and Find Full Text PDFRecent advancements in the high-speed long-range optical coherence tomography (OCT) endoscopy allow characterization of tissue compliance in the upper airway, an indicator of collapsibility. However, the resolution and accuracy of localized tissue compliance measurement are currently limited by the lack of a reliable nonuniform rotational distortion (NURD) correction method. In this study, we developed a robust 2-step NURD correction algorithm that can be applied to the dynamic OCT images obtained during the compliance measurement.
View Article and Find Full Text PDFNumerous techniques have been demonstrated for effective generation of orbital angular momentum-carrying radiation, but intracavity generation of continuously tunable pulses in the femtosecond regime remains challenging. Even if such a creation was realized, the generated pulses-like all pulses in reality-are complex and transitory objects that can only be comprehensively characterized via multidimensional spaces. An integrated lasing system that generates pulses while simultaneously quantifies them can achieve adaptive pulse tailoring.
View Article and Find Full Text PDFThe crystalline lens and cornea comprise the eye's optical system for focusing light in human vision. The changes in biomechanical properties of the lens and cornea are closely associated with common diseases, including presbyopia and cataract. Currently, most elasticity studies of the anterior eye focus on the measurement of the cornea, while lens measurement remains challenging.
View Article and Find Full Text PDFMultiple light scattering in biomedical tissue limits the penetration depth of optical imaging systems such as optical coherence tomography. To increase the imaging depth in scattering media, a computational method based on coherent reflection matrix measurement has been developed using low coherence interferometry. The complex reflection matrix is obtained via point-by-point scanning followed by a phase-shifting method; then singular value decomposition is used to retrieve the singly back-scattered light.
View Article and Find Full Text PDFFemale Pelvic Med Reconstr Surg
February 2020
Objective: Optical coherence tomography is a noninvasive technology that visualizes tissue microstructure with high spatial resolution. We designed a novel vaginal system that demonstrates a clear distinction between vaginal tissues planes. In this study, we sought to compare vaginal tomographic images of premenopausal, perimenopausal, and postmenopausal women, demonstrate feasibility of tracking vaginal tissue changes after treatment with fractional-pixel CO2 laser therapy, and obtain a histologic correlation of these findings.
View Article and Find Full Text PDFOtolaryngol (Sunnyvale)
April 2019
Diagnosis of inhalation injury has been clinically challenging. Currently, assessment of inhalation injury relies on subjective clinical exams and bronchoscopy, which provides little understanding of tissue conditions and results in limited prognostics. Endoscopic Optical coherence tomography (OCT) technology has been recently utilized in the airway for direct assessment of respiratory tract disorders and injuries.
View Article and Find Full Text PDFBackground: Acute respiratory distress syndrome (ARDS) is a severe form of acute lung injury with a mortality rate of up to 40%. Early management of ARDS has been difficult due to the lack of sensitive imaging tools and robust analysis software. We previously designed an optical coherence tomography (OCT) system to evaluate mucosa thickness (MT) after smoke inhalation, but the analysis relied on manual segmentation.
View Article and Find Full Text PDFWe present a very simple method of constructing a polarization-sensitive optical coherence tomography (PS-OCT) system. An ordinary fiber-based swept-source OCT system was reconfigured for PS-OCT by adding a long section of polarization-maintaining fiber in the sample arm. Two polarization modes of a large group-delay difference formed spatially distinguished polarization channels.
View Article and Find Full Text PDFTracking and monitoring implanted stem cells are essential to maximize benefits and to minimize the side effects of stem cell therapy for personalized or "precision" medicine. Previously, we proposed a comprehensive biological Global Positioning System (bGPS) to track and monitor stem cells . Magnetic resonance imaging (MRI), positron emission tomography (PET), bioluminescent imaging, fluorescence imaging, and single-photon emission computerized tomography (SPECT) have been utilized to track labeled or genetically-modified cells in rats and humans.
View Article and Find Full Text PDFLasers Surg Med
February 2019
Objectives: Optical coherence tomography (OCT) can noninvasively visualize in vivo tissue microstructure with high spatial resolution that approaches the histologic level. Currently, OCT studies in gynecology are few and limited to a conventional 1.3 μm center wavelength swept light source which provides high spatial resolution but limited penetration depth.
View Article and Find Full Text PDF