Background: Right ventricular failure (RVF) is a significant cause of morbidity and mortality in patients with a left ventricular assist device (LVAD). This study is aimed to investigate the influence of a pectus excavatum on early and late outcomes, specifically RVF, following LVAD implantation.
Methods: A retrospective study was performed, that included patients with a HeartMate 3 LVAD at our tertiary referral center.
Purpose: Because of the current lack of evidence-based antimicrobial treatment guidelines, Left Ventricular Assist Device (LVAD) infections are often treated according to local insights. Here, we propose a flowchart for protocolized treatment, in order to improve outcome.
Methods: The flowchart was composed based on literature, consensus and expert opinion statements.
Objectives: Right ventricular (RV) failure post left ventricular assist device (LVAD) implantation is associated with increased morbidity and mortality. A novel RV multi-plane imaging method using two-dimensional echocardiography and electronic plane rotation (MPE) was used to quantify RV function prior to LVAD implantation and to identify potential added value in this patient population.
Methods: In twenty-five end-stage heart failure patients (age 58.
Objectives: Driveline infections continue to be a significant complication following left ventricular assist device (LVAD) implantation. Driveline exit-site care is crucial for the prevention of infections; however, there are no uniform guidelines. The goal of this study was to provide an overview of the currently published driveline exit-site care protocols in patients with LVAD.
View Article and Find Full Text PDFPurpose: Poor left ventricular (LV) function may affect the physiological intraventricular blood flow and physiological vortex formation. The aim of this study was to investigate the pattern of intraventricular blood flow dynamics in patients with LV assist devices (LVADs) using echocardiographic particle image velocimetry.
Materials And Methods: This prospective study included 17 patients (mean age 57 ± 11 years, 82% male) who had received an LVAD (HeartMate 3, Abbott Laboratories, Chicago, Illinois, USA) because of end-stage heart failure and poor LV function.
Aims: The aim of this study was to compare early- and late-term survival and causes of death between patients with and without a concomitant aortic valve (AoV) procedure during continuous-flow left ventricular assist device (LVAD) surgery.
Methods And Results: All adult primary continuous-flow LVAD patients on the International Society of Heart and Lung Transplantation (ISHLT) Mechanically Assisted Circulatory Support (IMACS) Registry (n = 15 267) were included in this analysis and stratified into patients submitted to a concomitant AoV procedure (AoV replacement or AoV repair) and patients without an AoV procedure. The primary outcome was early (≤90 days) survival post-LVAD surgery.
Data on the risk of aortic root thrombosis in patients with aortic valve replacement (AVR) and left ventricular assist device (LVAD) surgery are scarce. Two out of nine patients receiving AVR concomitant with LVAD surgery and two out of two patients receiving AVR on LVAD support, at our centre, developed an aortic root thrombus, all diagnosed with computed tomography (CT) angiography. These results demonstrate that patients with concomitant AVR and LVAD surgery, or AVR on LVAD support, have an increased risk of aortic root thrombosis.
View Article and Find Full Text PDFAims: Sufficient myocardial recovery with the subsequent explantation of a left ventricular assist device (LVAD) occurs in approximately 1-2% of the cases. However, follow-up data about this condition are scarcely available in the literature. This study aimed to report the long-term outcomes and clinical management following LVAD explantation.
View Article and Find Full Text PDFAims: To investigate the prevalence of electromagnetic interference (EMI) between left ventricular assist devices (LVADs) and implantable cardioverter-defibrillators (ICDs)/pacemakers (PMs).
Methods And Results: A retrospective single-centre study was conducted, including all patients undergoing HeartMate II (HMII) and HeartMate 3 (HM3) LVAD implantation (n = 106). Electromagnetic interference was determined by the inability to interrogate the ICD/PM.
Background: Many patients undergoing durable left ventricular assist device (LVAD) implantation suffer from chronic kidney disease (CKD). Therefore, we investigated the effect of LVAD support on CKD.
Methods: A retrospective multicenter cohort study, including all patients undergoing LVAD (HeartMate II (n = 330), HeartMate 3 (n = 22) and HeartWare (n = 48) implantation.
Objectives: We evaluated the impact of preoperative liver function on early and 1-year postoperative outcomes in patients supported with a left ventricular assist device (LVAD) and subsequent evolution of liver function markers.
Methods: A retrospective multicentre cohort study was conducted, including all patients undergoing continuous-flow LVAD implantation. The Model for End-stage Liver Disease (MELD) score was used to define liver dysfunction.
Currently, an increasing number of patients with end-stage heart failure are being treated with left ventricular assist device (LVAD) therapy as bridge-to-transplantation, bridge-to-candidacy, or destination therapy (DT). Potential life-threatening complications may occur, specifically in the early post-operative phase, which positions LVAD implantation as a high-risk surgical procedure. Acute kidney injury (AKI) is a frequently observed complication after LVAD implantation and is associated with high morbidity and mortality.
View Article and Find Full Text PDFNeurologic events occur in up to 18% of patients with continuous-flow left ventricular assist devices (LVAD) and is associated with significant morbidity and mortality. The current form of the LVAD equipment is not suited to serve patients who are impaired by a stroke. By creating an assistance device for the LVAD equipment, we have been able to greatly improve the quality of life and self-dependence of a hemiplegic LVAD patient.
View Article and Find Full Text PDF