Guang Pu Xue Yu Guang Pu Fen Xi
May 2015
Fiber-coupling surface Plasmon resonance sensor has attractive advantages of information transmission such as small volume, anti-electric magnetic field interference, and online real-time remote detection. In order to improve the performance of the sensor, the effect of the residual fiber thickness and the silver film thickness to the sensitivity of the sensor and the depth of the resonance peaks and full width ar half maximum (FWHM) are analyzed respectively. The results show that the increasing fiber residual thickness weakens the SPR phenomenon, and that the increasing silver film thickness widens the resonance peak, while the sensitivity of the sensor does not change monotonously.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
March 2014
Surface plasmon resonance, which utilizes the resonance of optical evanescent wave with the metal surface plasmon wave, has been developed into a high sensitivity, rapid, label-less measurement method for chemical and biological analysis. In order to improve the spectral sensitivity in refractive index for a side polished fiber surface plasmon resonance sensor, the whole cladding layer and part of core of a multimode fiber was polished off. Additionally, an extra chrome layer with relatively high refractive index was coated on the polished zone before a gold film.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
May 2014
Surface plasmon resonance (SPR) is a rapid, label-free, high-precision technique of biological sensing and analysis. The investigation on the characteristics of provides theoretical basis and instructions for the applications of SPR A Kretschmann-structure surface plasmon resonance (SPR) biosensor based on wavelength modulation was developed, and also its sensing performances in the bulk solution was investigated. Measurements with different concentrations of bulk ethanol and ethylene glycol solutions show that the resonant wavelength shows a low sensitivity, but a higher linear response to the change in refractive index (RI), when RI is relatively smaller.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
October 2010
Near infrared transmission spectroscopy of Whole blood are investigated with different thickness (0.5, 1, 2, 4 mm) in order to explore the feasibility of detecting alanine aminotransferase rapidly by near-infrared spectra. The results show that the whole blood sample with 0.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
August 2006
In the present paper, the authors analyzed the absorption and scattering effects of changing the solution concentration on the spectra, and dealed with the wavelength, where the absorption and scattering effects counteract completely, the fiducial wavelength method can eliminate the perturbation from shift of instrument and temperature, and also can improve predicting ability of the model. The result of utilizing this method to process the spectral data of two sample sets, i. e.
View Article and Find Full Text PDF