Introduction: Radiation planning approaches for liver radiation often do not consider the regional variation that can exist in liver function. This study dosimetrically compares functional liver image-guided hepatic therapy (FLIGHT) to standard stereotactic body radiation therapy (SBRT) plans. In the FLIGHT plans, functional data from hepatobiliary iminodiacetic acid (HIDA) single photon emission computed tomography (SPECT) scans serve as a road map to guide beam arrangement.
View Article and Find Full Text PDFPurpose: Hepatobiliary iminodiacetic acid (HIDA) scans provide global and regional assessments of liver function that can serve as a road map for functional avoidance in stereotactic body radiation therapy (SBRT) planning. Functional liver image guided hepatic therapy (FLIGHT), an innovative planning technique, is described and compared with standard planning using functional dose-volume histograms. Thresholds predicting for decompensation during follow up are evaluated.
View Article and Find Full Text PDF