Publications by authors named "Yuji Iyama"

Background: The aim of this study was to evaluate the quality and diagnostic performance of virtual monochromatic images (VMI) obtained with dual-layer dual-energy computed tomography (DL-DECT) during indirect CT venography (CTV) for deep vein thrombosis (DVT).

Methods and results: This retrospective study was approved by the Institutional Review Board, which waived the requirement for informed consent. We retrospectively enrolled 45 patients who underwent CTV with DL-DECT, and VMI were retrospectively generated.

View Article and Find Full Text PDF

Purpose: The hybrid compressed sensing (hybrid-CS) technique can shorten the acquisition time compared with the sensitivity encoding (SENSE) technique in lumbar MRI. To evaluate the feasibility of a hybrid-CS technique in comparison with 3D isotropic T-weighted turbo spin-echo (3D volume isotropic turbo spin-echo acquisition [VISTA]) MRI of the lumbar spine.

Materials And Methods: The Institutional Review Board approved this study and informed consent was obtained from participants prior to study entry.

View Article and Find Full Text PDF

Rationale And Objective: Uterine leiomyomas with high signal intensity on T2-weighted imaging (T2WI) can be difficult to distinguish from sarcomas. This study assessed the feasibility of using machine learning to differentiate uterine sarcomas from leiomyomas with high signal intensity on T2WI on multiparametric magnetic resonance imaging.

Materials And Methods: This retrospective study included 80 patients (50 with benign leiomyoma and 30 with uterine sarcoma) who underwent pelvic 3 T magnetic resonance imaging examination for the evaluation of uterine myometrial smooth muscle masses with high signal intensity on T2WI.

View Article and Find Full Text PDF

Objectives: To evaluate the effect of a spiral tube on contrast enhancement in the hepatic arterial phase (HAP) of gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI).

Methods: In this retrospective study, we observed 104 patients who underwent dynamic MRI of the liver between October 2017 and December 2017. Three Gd-EOB-DTPA injection protocols were compared: (A) conventional method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s, n = 36); (B) spiral dilution method (1:1 diluted Gd-EOB-DTPA with saline [off-label], injection rate 2 ml/s via spiral tube, n = 38); (C) spiral-flushed method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s via spiral tube, n = 30).

View Article and Find Full Text PDF

Repeatability of quantitative assessment of atherosclerotic plaques is important for the accurate detection of high-risk plaques in coronary CT angiography (CTA). We assessed the effect of heart rate (HR) on plaque CT number using a coronary artery model and a cardiac phantom capable of simulating cardiac motion. The coronary artery model with luminal stenosis on a cardiac phantom was imaged with a simulated HR of 0, 50, 60, and 70 beats per minute using a 320-row CT scanner.

View Article and Find Full Text PDF

We aimed to evaluate the image quality performance of coronary CT angiography (CTA) under the different settings of forward-projected model-based iterative reconstruction solutions (FIRST).Thirty patients undergoing coronary CTA were included. Each image was reconstructed using filtered back projection (FBP), adaptive iterative dose reduction 3D (AIDR-3D), and 2 model-based iterative reconstructions including FIRST-body and FIRST-cardiac sharp (CS).

View Article and Find Full Text PDF

We describe a case of lumbar stenosis in which retrospective spectral analysis using dual-layer spectral detector computed tomography (CT) had the ability to expand the evaluable region in the spinal canal. Spinal canal stenosis is a common condition whose symptoms (such as lower back and leg pain with walking) deteriorate the quality of life. Generally, magnetic resonance imaging (MRI) and CT myelography are performed to diagnose canal stenosis.

View Article and Find Full Text PDF

The aim of this study was to evaluate the effect of patient characteristics on the contrast agent dosage that is required to reach effective enhancement of the inferior vena cava (IVC) on computed tomography venographs (CTV).This retrospective study included 50 patients who underwent CTV at 80 kVp. The contrast injection protocol (iodine 600 mg/kg) was tailored to their body weight.

View Article and Find Full Text PDF

Rationale And Objectives: To assess the effect of model-based iterative reconstruction (MBIR) on image quality and diagnostic performance of low-radiation-dose computed tomography colonography (CTC) in the preoperative assessment of colorectal cancer.

Materials And Methods: This study included 30 patients with colorectal cancer referred for surgical treatment. All patients underwent CTC with a standard dose (SD) protocol in the supine position and a low-dose (LD; radiation dose reduction of approximately 85%) protocol in the prone position.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare scan time and image quality between magnetic resonance angiography (MRA) of the thoracic aorta using a multi-shot gradient echo planar imaging (MSG-EPI) and MRA using balanced steady-state free precession (b-SSFP).

Materials And Methods: Healthy volunteers (n=17) underwent unenhanced thoracic aorta MRA using balanced steady-state free precession (b-SSFP) and MSG-EPI sequences on a 3T MRI. The acquisition time, total scan time, signal-to-noise ratio (SNR) of the thoracic aorta, and the coefficient of variation (CV) of thoracic aorta were compared with paired t-tests.

View Article and Find Full Text PDF

Objective: Different CT scanners have different X-ray spectra and photon energies indicating that contrast enhancement vary among scanners. However, this issue has not been fully validated; therefore, we performed phantom and clinical studies to assess this difference.

Methods: Two scanners were used: scanner-A and scanner-B.

View Article and Find Full Text PDF

Objective: We compared the effect of a dual-region-of-interest (ROI) bolus-tracking technique on interpatient variability of arterial contrast enhancement with that of the conventional bolus-tracking technique in coronary computed tomographic angiography (CTA) on a 320-row scanner.

Methods: This study included 100 patients who underwent coronary CTA using one of two protocols: (1) 50 patients underwent scanning using a conventional single-ROI bolus-tracking technique (P-single) with an ROI placed in the ascending aorta, and (2) 50 patients underwent scanning using a dual-ROI technique (P-dual) with two ROIs placed in the pulmonary trunk and the ascending aorta. CT attenuation in the ascending aorta and coronary arteries, and the interpatient variability were compared between the two scanning protocols.

View Article and Find Full Text PDF

Objectives: To evaluate the image quality and lesion conspicuity of virtual-monochromatic-imaging (VMI) with dual-layer DECT (DL-DECT) for reduced-iodine-load multiphasic-hepatic CT.

Methods: Forty-five adults with renal dysfunction who had undergone hepatic DL-DECT with 300-mgI/kg were included. VMI (40-70-keV, DL-DECT-VMI) was generated at each enhancement phase.

View Article and Find Full Text PDF

Background: Cardiac computed tomography (CT) has the potential for fully four-dimensional (4D for 3D plus time) motion analysis of the heart. We aimed at developing a method for assessment and presentation of the 4D motion for multi-phase, contrast-enhanced cardiac CT data sets and demonstrating its clinical applicability.

Methods: Four patients with normal cardiac function, old myocardial infarction (OMI), takotsubo cardiomyopathy, and hypertrophic cardiomyopathy (HCM) underwent contrast-enhanced cardiac CT for one heartbeat using a 320-row CT scanner with no tube current modulation.

View Article and Find Full Text PDF

Purpose: We investigated the feasibility of single breath hold unenhanced coronary MRA using multi-shot gradient echo planar imaging (MSG-EPI) on a 3T-scanner.

Methods: Fourteen volunteers underwent single breath hold coronary MRA with a MSG-EPI and free-breathing turbo field echo (TFE) coronary MRA at 3T. The acquisition time, signal to noise ratio (SNR), and the contrast of the sequences were compared with the paired t-test.

View Article and Find Full Text PDF

Objective: To compare the quality of fat suppression and image quality between multiecho Dixon technique (mDixon) and spectrally adiabatic iversion recovery (SPAIR) in dynamic contrast-enhanced magnetic resonance imaging of the prostate.

Methods: This prospective study assigned thirty consecutive patients to scanning with SPAIR technique (SPAIR protocol) and another consecutive 30 patients to scanning with mDixon technique (mDixon protocol). We calculated the contrast, signal to noise ratio (SNR), contrast to noise ratio (CNR) and the coefficient of variation between the 2 protocols.

View Article and Find Full Text PDF

Objectives: The objective of this study is to evaluate the usefulness of iterative model reconstruction designed for brain computed tomography (CT) (IMR-Neuro) for the diagnosis of acute ischemic stroke.

Methods: This retrospective study included 20 patients with acute middle cerebral artery infarction who have undergone brain CT and 20 nonstroke patients (control). We reconstructed axial images with filtered back projection (FBP) and IMR-Neuro (slice thickness, 1 and 5 mm).

View Article and Find Full Text PDF

Objectives: The objective of this study was to evaluate the use of 80-kVp scans with knowledge-based iterative model reconstruction (IMR) for computed tomography venography (CTV).

Methods: This prospective study received institutional review board approval; a previous informed consent was obtained from all participants. We enrolled 30 patients with suspected deep venous thrombosis or pulmonary embolism who were to undergo 80-kVp CTV studies.

View Article and Find Full Text PDF

Purpose: To develop a prediction model to distinguish between transition zone (TZ) cancers and benign prostatic hyperplasia (BPH) on multi-parametric prostate magnetic resonance imaging (mp-MRI).

Materials And Methods: This retrospective study enrolled 60 patients with either BPH or TZ cancer, who had undergone 3 T-MRI. We generated ten parameters for T2-weighted images (T2WI), diffusion-weighted images (DWI) and dynamic MRI.

View Article and Find Full Text PDF
Article Synopsis
  • - This study aimed to evaluate and compare the image quality and artifacts in Gd-EOB-DTPA-enhanced MRI by using two different methods: test-bolus and bolus-tracking.
  • - Involving 60 patients, results showed that the test-bolus method significantly improved signal-to-noise ratios in both liver and spleen, as well as optimal timing for hepatic arterial phase imaging, compared to bolus-tracking.
  • - The findings concluded that the test-bolus protocol provided better image quality and reduced motion and ringing artifacts compared to the bolus-tracking protocol in dynamic 3-T MRI.
View Article and Find Full Text PDF

Purpose To evaluate the image quality and interobserver reproducibility of unenhanced lumbar spinal computed tomography (CT) images reconstructed with iterative model reconstruction (IMR). Materials and Methods This prospective study was approved by the local ethics committee, and written informed consent was obtained from all patients. The study included 34 patients scanned with unenhanced CT and magnetic resonance (MR) imaging for lumbar canal spinal stenosis.

View Article and Find Full Text PDF

Rationale And Objectives: We compared the effect of iterative model reconstruction (IMR), filtered back projection (FBP), and hybrid iterative reconstruction (HIR) on coronary artery calcium (CAC) scoring.

Materials And Methods: CAC scans of 30 consecutive patients (18 men and 12 women, age 70.1 ± 12.

View Article and Find Full Text PDF

To compare the radiation dose and image quality of retrospective electrocardiogram (ECG)-gated cardiac computed tomography (CT) between a 100-kVp protocol, hybrid iterative reconstruction (HIR), and display preset optimization and the 120-kVp protocol.We prospectively enrolled 100 patients with tachycardia or atrial fibrillation scanned retrospective ECG-gated cardiac CT. We randomly assigned 50 patients to the 120-kVp protocol and 50 patients to the 100-kVp protocol.

View Article and Find Full Text PDF

Rationale And Objectives: The purpose of this study was to evaluate the noise and image quality of images reconstructed with a knowledge-based iterative model reconstruction (knowledge-based IMR) in ultra-low dose cardiac computed tomography (CT).

Materials And Methods: We performed submillisievert radiation dose coronary CT angiography on 43 patients. We also performed a phantom study to evaluate the influence of object size with the automatic exposure control phantom.

View Article and Find Full Text PDF

Rationale And Objectives: We investigated the effects of small focal spot (SFS) imaging and iterative model reconstruction (IMR) on the image quality of computed tomography angiographs (CTA) in patients with peripheral arterial disease.

Materials And Methods: We divided 60 consecutive patients with suspected or confirmed peripheral artery disease into two equal groups. One group underwent large focal spot scanning under our standard CTA protocol with hybrid iterative reconstruction (iDose(4)) (protocol 1), and the other underwent scanning with the SFS protocol and IMR (protocol 2).

View Article and Find Full Text PDF