Analytical techniques using ATP bioluminescence, which has a high quantum yield and substrate specificity, are widely used in various assays, such as luciferase reporter assays, in the biological sciences. Although most microplate luminometers can be used to measure ATP luminescence with 96-well or 384-well microplates, their ATP detection limits are typically several tens of amol, which is not sufficient for evaluating cell activities and variability within small samples, such as those containing only a few cells. To analyze cell activities at low ATP concentrations, a more sensitive microplate luminometer is required.
View Article and Find Full Text PDFAdministering appropriate antimicrobial therapy as early as possible is important for rescuing bacteremic patients. Therefore, rapid antimicrobial susceptibility tests in positive blood culture specimens have been diligently sought. Adenosine triphosphate (ATP) bioluminescence-based methods have been used for rapid antimicrobial susceptibility tests.
View Article and Find Full Text PDFA five-color fluorescence-detection system for eight-channel plastic-microchip electrophoresis was developed. In the eight channels (with effective electrophoretic lengths of 10 cm), single-stranded DNA fragments were separated (with single-base resolution up to 300 bases within 10 min), and seventeen-loci STR genotyping for forensic human identification was successfully demonstrated. In the system, a side-entry laser beam is passed through the eight channels (eight A channels), with alternately arrayed seven sacrificial channels (seven B channels), by a technique called "side-entry laser-beam zigzag irradiation.
View Article and Find Full Text PDFA far-ultraviolet (FUV)-absorbance detector with a transmission flow cell was developed and applied to detect absorbance of sugars and peptides by HPLC. The main inherent limitation of FUV-absorbance detection is the strong absorptions of solvents and atmospheric oxygen in the optical system as well as dissolved oxygen in the solvent. High absorptivity of the solvent and oxygen decreases transmission-light intensity in the flow cell and hinders the absorbance measurement.
View Article and Find Full Text PDFA simple and highly sensitive technique for laser-induced fluorescence detection on multiple channels in a plastic microchip was developed, and its effectiveness was demonstrated by laser-beam ray-trace simulations and experiments. In the microchip, with refractive index nC, A channels and B channels are arrayed alternately and respectively filled with materials with refractive indexes nA for electrophoresis analysis and nB for laser-beam control. It was shown that a laser beam entering from the side of the channel array traveled straight and irradiated all A channels simultaneously and effectively because the refractive actions by the A and B channels were counterbalanced according to the condition nA < nC < nB.
View Article and Find Full Text PDFElectromagnetic wave emission based on optical rectification at terahertz (THz) wavelengths was observed from surface-immobilized gold nanospheres (SIGNs) above a gold surface. Although the excitation wavelength is off-resonant with the localized surface plasmons, the THz emission field was observed to be approximately 4.8 times greater than that from a percolated gold thin film of 10 nm thickness.