Angew Chem Int Ed Engl
September 2024
Despite the proliferation of multiple resonance (MR) materials in the blue to green spectral ranges, red MR emitters remain scarce in the literature, an area that certainly warrants attention for future applications. Here, through a clever application of classic Clar's aromatic π-sextet rule, we triumphantly constructed the first red MR emitter by substituting the conventional benzene ring core with anthracene (fewer π-sextets). Theoretical studies indicate that the quantity of π-sextets ultimately determines the optical band gap of a molecule, rather than the number of fused benzene rings.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
November 2024
Thermally activated delayed fluorescence (TADF) emitters with a high horizontal orientation are highly essential for improving the external quantum efficiency (EQE) of organic light-emitting diodes; however, pivotal molecular design strategies to improve the horizontal orientation of solution-processable TADF emitters are still scarce and challenging. Herein, a phenyl bridge is adopted to connect the double TADF units, and generate a dimerized TADF dendrimer, D4CzBNPh-SF. Compared to its counterpart with a single TADF unit, the proof-of-the-concept molecule not only exhibits an improved horizontal dipole ratio (78 %) due to the π-delocalization-induced extended molecular conjugation, but also displays a faster reversed intersystem crossing rate constant (6.
View Article and Find Full Text PDFFluorescence (FL) imaging in the second near-infrared window (NIR-II, 1000-1700 nm) has emerged as a promising bioimaging modality that enables noninvasive visualization of deep tissue with an unprecedented resolution. However, there is a paucity of studies on high-quality responsive NIR-II FL molecules. Herein we report a novel activated NIR-II FL molecule, 4,7-bis(5-(4-(diphenylamine)phenyl)-2-thiophene) [1,2,5]selenadiazolo[3,4-]benzo[][1,2,5]thiadiazole (SeTT), which exhibits fast and specific responsive capability to hypochlorous acid (HClO).
View Article and Find Full Text PDFA water-stable and pH-independent sensor for qualitative and quantitative detection of nicotine in urine solution and living cell was successfully developed. This material, named MB@UiO-66-NH, can be synthesized by encapsulating methylene blue (MB) with a well-known metal-organic framework (MOF) UiO-66-NH through a simple impregnation method. The fluorescence intensity of the system was significantly enhanced when a certain amount of nicotine was added.
View Article and Find Full Text PDF