Arch Orthop Trauma Surg
November 2024
Introduction: The comparison between the cementless taper wedge stem and fit-and-fill stem in total hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly assessed. This study aimed to compare the risk of leg length discrepancy (LLD) ≥ 10 mm between these two stem types in Dorr type A, B, and C femurs.
Materials And Methods: From April 2015 through April 2021, we analyzed 1178 unilateral primary cementless THA procedures.
Introduction: The choice between a cementless taper wedge stem and a fit-and-fill stem in total Hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly evaluated. This study aimed to compare the risk of stem-related complications between these two stem types in Dorr type A, B, and C femurs.
Materials And Methods: From January 2015 through April 2021, we retrospectively reviewed 1995 cementless THA procedures.