The Advanced Research Projects Agency for Health (ARPA-H) is a new federal agency established by the Biden administration in March 2022 to accelerate US government-funded biomedical and health solutions. ARPA-H has a distinct operating model, leadership structure, and funds flow separate from the National Institutes of Health. In 2023, the Association of Academic Radiology formed a Radiology Research Alliance taskforce to better understand the mission, vision, and guiding principles of ARPA-H and relevance to radiology and biomedical imaging research.
View Article and Find Full Text PDFCurrent clinical small molecule x-ray CT agents are effective but pose risks such as nephrotoxicity, short blood circulation time, limiting scan durations, potential thyroid impact, and immune responses. These challenges drive the development of kidney-safe x-ray nanoparticle (NP)-based contrast agents (CAs), though translation to clinical practice is hindered by chemical complexities and potential toxicity. We have engineered an intravenous, injectable, and safe blood pool NP-based CT CAs at a clinical-equivalent dose of ∼300 mgI/kg (∼2 mL/kg), ideal for vascular and hepatic imaging which are limited by clinical agents.
View Article and Find Full Text PDFExtended reality (XR) simulations are becoming increasingly common in educational settings, particularly in medical education. Advancing XR devices to enhance these simulations is a booming field of research. This study seeks to understand the value of a novel, non-wearable mixed reality (MR) display during interactions with a simulated holographic patient, specifically in taking a medical history.
View Article and Find Full Text PDFThis study explores the feasibility of a stationary gantry cardiac gated computed tomography (CT) with carbon nanotube (CNT) linear x-ray source arrays.We developed a stationary gantry CT system utilizing multipixel CNT x-ray sources. Given the advantages of straightforward x-ray pulse control with these sources, we investigated the potential for gated prospective imaging.
View Article and Find Full Text PDFDual-energy cone beam computed tomography (DE-CBCT) has been shown to provide more information and improve performance compared to a conventional single energy spectrum CBCT. Here we report a low-cost DE-CBCT by spectral filtration of a carbon nanotube x-ray source array. The x-ray photons from two focal spots were filtered respectively by a low and a high energy filter.
View Article and Find Full Text PDFCone beam computed tomography (CBCT) is known to suffer from strong scatter and cone beam artifacts. The purpose of this study is to develop and characterize a rapidly scanning carbon nanotube (CNT) field emission x-ray source array to enable a multisource CBCT (ms-CBCT) image acquisition scheme which has been demonstrated to overcome these limitations. A CNT x-ray source array with eight evenly spaced focal spots was designed and fabricated for a medium field of view ms-CBCT for maxillofacial imaging.
View Article and Find Full Text PDFAntineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV) is a group of rare conditions predominantly affecting small vessels of skin, musculoskeletal, pulmonary, renal, and rarely central and peripheral nervous systems. Isolated neurological manifestations of AAV are uncommon and challenging to diagnose. Cocaine has been reported as a potential trigger for the development of AAV.
View Article and Find Full Text PDFBackground: Digital subtraction angiography (DSA) yields high cumulative radiation dosages (RD) delivered to patients. We present a temporal interpolation of low frame rate angiograms as a method to reduce cumulative RDs.
Methods: Patients undergoing interventional evaluation and treatment of cerebrovascular vasospasm following subarachnoid hemorrhage were retrospectively identified.
Purpose: Endometriosis is an estrogen-dependent disorder of menstruating primates where tissues similar to the inner lining of the uterus exist "ectopically" outside of the uterus. The ectopic endometrium, like the endometrium within the uterus, expresses estrogen receptors (ER) and progesterone receptors (PR) and undergoes hormone-dependent cell proliferation and bleeding each menstrual cycle. The goal of this study was to conduct abdominopelvic positron emission tomography (PET) scans with computed tomography (CT) imaging of rhesus macaques (Macaca mulatta) using radiotracers that target ER and PR [16α-[F]fluoroestradiol (FES) and 12-[F]fluoro-furanyl-nor-progesterone (FFNP)] in individuals with and without endometriosis.
View Article and Find Full Text PDFThe use of needles to access sites within organs is fundamental to many interventional medical procedures both for diagnosis and treatment. Safely and accurately navigating a needle through living tissue to a target is currently often challenging or infeasible because of the presence of anatomical obstacles, high levels of uncertainty, and natural tissue motion. Medical robots capable of automating needle-based procedures have the potential to overcome these challenges and enable enhanced patient care and safety.
View Article and Find Full Text PDFPurpose: Few investigations have examined the uptake of radiotracers that target the prominent sex-steroid receptors in the uterus across the menstrual cycle and with disease state. We aimed to determine if uptake of the radiotracers that target estrogen and progesterone receptors (ER and PR) differ with the presence of endometriosis and/or across the menstrual cycle. We performed PET and computed tomography (CT) imaging procedures on rhesus macaques () using 16α-[18F]fluoroestradiol (FES) and 21-[18F]fluoro-furanyl-nor-progesterone (FFNP) in individuals with and without endometriosis in the proliferative and secretory phases of the menstrual cycle.
View Article and Find Full Text PDFObjective: Caffeine provides neuroprotection following hypoxic-ischemic injury in animals. We characterized the safety of escalating doses of caffeine in infants with hypoxic-ischemic encephalopathy (HIE) receiving therapeutic hypothermia.
Study Design: Phase I trial of infants undergoing therapeutic hypothermia for HIE receiving IV caffeine 20 mg/kg followed by up to two daily doses of 5 mg/kg (n = 9) or 10 mg/kg (n = 8).
Objective: The goal of this work was to methodically evaluate, optimize, and validate a self-supervised machine learning algorithm capable of real-time automatic registration and fluoroscopic localization of the spine using a single radiograph or fluoroscopic frame.
Methods: The authors propose a two-dimensional to three-dimensional (2D-3D) registration algorithm that maximizes an image similarity metric between radiographic images to identify the position of a C-arm relative to a 3D volume. This work utilizes digitally reconstructed radiographs (DRRs), which are synthetic radiographic images generated by simulating the x-ray projections as they would pass through a CT volume.
. The aim of this study was to investigate the feasibility of improving the image quality and accuracy of cone beam computed tomography (CBCT) by replacing the conventional wide cone angle x-ray tube with a distributed x-ray source array positioned in the axial direction..
View Article and Find Full Text PDFClinical trials of combined IDO/PD1 blockade in metastatic melanoma (MM) failed to show additional clinical benefit compared to PD1-alone inhibition. We reasoned that a tryptophan-metabolizing pathway other than the kynurenine one is essential. We immunohistochemically stained tissues along the nevus-to-MM progression pathway for tryptophan-metabolizing enzymes (TMEs; TPH1, TPH2, TDO2, IDO1) and the tryptophan transporter, LAT1.
View Article and Find Full Text PDFPurpose: To explore the feasibility of measuring ventilation defect percentage (VDP) using F MRI during free-breathing wash-in of fluorinated gas mixture with postacquisition denoising and to compare these results with those obtained through traditional Cartesian breath-hold acquisitions.
Methods: Eight adults with cystic fibrosis and 5 healthy volunteers completed a single MR session on a Siemens 3T Prisma. H Ultrashort-TE MRI sequences were used for registration and masking, and ventilation images with F MRI were obtained while the subjects breathed a normoxic mixture of 79% perfluoropropane and 21% oxygen (O ).
Cone beam computed tomography (CBCT) is widely used in medical and dental imaging. Compared to a multidetector CT, it provides volumetric images with high isotropic resolution at a reduced radiation dose, cost and footprint without the need for patient translation. The current CBCT has several intrinsic limitations including reduced soft tissue contrast, inaccurate quantification of X-ray attenuation, image distortions and artefacts, which have limited its clinical applications primarily to imaging hard tissues and made quantitative analysis challenging.
View Article and Find Full Text PDFThe availability of highly effective CFTR modulators is revolutionizing the treatment of cystic fibrosis (CF) and drastically improving outcomes. MRI-based imaging modalities are now emerging as highly sensitive endpoints, particularly in the setting of mild lung disease. Adult CF patients were recruited from a single center prior to starting treatment with E/T/I.
View Article and Find Full Text PDFA subset of individuals who recover from coronavirus disease 2019 (COVID-19) develop post-acute sequelae of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (PASC), but the mechanistic basis of PASC-associated lung abnormalities suffers from a lack of longitudinal tissue samples. The mouse-adapted SARS-CoV-2 strain MA10 produces an acute respiratory distress syndrome in mice similar to humans. To investigate PASC pathogenesis, studies of MA10-infected mice were extended from acute to clinical recovery phases.
View Article and Find Full Text PDFBackground: Screen detected and incidental pulmonary nodules are increasingly common. Current guidelines recommend tissue sampling of solid nodules >8 mm. Bronchoscopic biopsy poses the lowest risk but is paired with the lowest diagnostic yield when compared to CT-guided biopsy or surgery.
View Article and Find Full Text PDFCOVID-19 survivors develop post-acute sequelae of SARS-CoV-2 (PASC), but the mechanistic basis of PASC-associated lung abnormalities suffers from a lack of longitudinal samples. Mouse-adapted SARS-CoV-2 MA10 produces an acute respiratory distress syndrome (ARDS) in mice similar to humans. To investigate PASC pathogenesis, studies of MA10-infected mice were extended from acute disease through clinical recovery.
View Article and Find Full Text PDFCone beam computed tomography (CBCT) is now widely used in dentistry and growing areas of medical imaging. The presence of strong metal artifacts is however a major concern of using CBCT especially in dentistry due to the presence of highly attenuating dental restorations, fixed appliances, and implants. Virtual monoenergetic images (VMIs) synthesized from dual energy CT (DECT) datasets are known to reduce metal artifacts.
View Article and Find Full Text PDF