We present a portable single-shot lens-free tomographic microscope, based on spatial multiplexing in-line digital holography, for three-dimensional (3D) imaging of dynamic specimens. The simplified system is realized by only a laser diodes array, a rectangular aperture, and a CMOS image sensor with a global shutter, which enables the recording of all the complex fields of a dynamic specimen from different illumination angles without any scanning mechanism by a multiplexing hologram, in a single camera exposure. Using our proposed data processing method, high-quality 3D tomograms, with a lateral resolution of 3.

View Article and Find Full Text PDF

We present a space-angle dual multiplexing holographic recording system for realizing single-exposure multi-wavelength optical diffraction tomographic (ODT) imaging. This system is achieved by combining the principle of single-exposure multi-wavelength holographic imaging technique based on angle-division multiplexing with the principle of single-exposure ODT imaging technique based on microlens array multi-angle illuminations and space-division multiplexing. Compared with the existing multi-wavelength ODT imaging methods, it enables the holographic recording of all the diffraction tomography information of a measured specimen at multiple illumination wavelengths in a single camera exposure without any scan mechanism.

View Article and Find Full Text PDF

We present a new, to the best of our knowledge, type of off-axis digital holographic imaging method with a long field of view (FOV). In the method, the pre-magnification recording geometry is realized by a cylindrical lens (CL) or cylindrical beam instead of a conventional objective or spherical beam in traditional off-axis digital holography (DH). At the same time, the reference beam is replaced by a divergent cylindrical beam.

View Article and Find Full Text PDF

In this work, we report on the preparation and characterization of the planar and ridge optical waveguides in the -doped germanate glass by combining hydrogen ion implantation and precise diamond blade dicing. The nuclear energy loss and the implantation depth were calculated by the SRIM 2013 software. The refractive index profile was obtained by the reflectivity calculation method.

View Article and Find Full Text PDF

In our work, passively mode-locked and Q-switched Er-doped fiber lasers (EDFLs) based on titanium disulfide (TiS) as a saturable absorber (SA) were generated successfully. Stable mode-locked pulses centred at 1531.69 nm with the minimum pulse width of 2.

View Article and Find Full Text PDF

Accumulation of DNA damage has been detected in the spinal cord of patients as well as in the G93A mouse model of amyotrophic lateral sclerosis (ALS). Wild-type p53-induced phosphatase 1 (Wip1) is a p53-inducible serine/threonine phosphatase that terminates DNA-damage responses via dephosphorylation of DNA-damage response proteins, namely ataxia-telangiectasia mutated (ATM) kinase, checkpoint kinase 2, and p53, thus enhancing cell proliferation. However, the role of Wip1, DNA-damage responses, and their interaction in ALS development remains to be elucidated.

View Article and Find Full Text PDF

Mass transport driven by temperature gradient is commonly seen in fluids. However, here we demonstrate that when drawing a cold nano-tip off a hot solid substrate, thermomigration can be so rampant that it can be exploited for producing single-crystalline aluminum, copper, silver and tin nanowires. This demonstrates that in nanoscale objects, solids can mimic liquids in rapid morphological changes, by virtue of fast surface diffusion across short distances.

View Article and Find Full Text PDF

A compact system for single-shot sequential holographic imaging (SSSHI) with high temporal resolution and a large field of view is proposed. In this system, a specially designed sequence pulse train generator with a group of diffractive gratings inserted is adopted to simultaneously generate the probe pulse train and the reference pulse train required for recording a single-shot spatial frequency division multiplexing hologram. The system successfully overcomes the walk-off effect of the ultrashort pulse laser in SSSHI and, hence, effectively avoids the influence of the short coherence of ultrashort pulses on the spatial resolution (or field of view) of SSSHI; the complexity of the system and the difficulty in the precise synchronous alignment of the probe and the reference pulses also can be greatly reduced.

View Article and Find Full Text PDF

A method for realizing 2D single-shot measurements of birefringence parameters (including both retardation and optic axis orientation) of anisotropic materials using a simple recording setup and an efficient processing algorithm is proposed. The recording setup can be built simply by inserting a circular polarizer and a polarization beam splitter, respectively, in the object path and reference path of a conventional off-axis holographic imaging system, with no need for other adjustments. An algorithm for quantitatively retrieving the birefringence parameters from one single-shot hologram is proposed and demonstrated, in which a new quantity describing the birefringence, called complex birefringence parameter, is introduced, and a set of formulas used to extract the birefringence parameters is derived.

View Article and Find Full Text PDF

Increasing evidence indicates that DNA damage and p53 activation play major roles in the pathological process of motor neuron death in amyotrophic lateral sclerosis (ALS). Human SpeedyA1 (Spy1), a member of the Speedy/Ringo family, enhances cell proliferation and promotes tumorigenesis. Further studies have demonstrated that Spy1 promotes cell survival and inhibits DNA damage-induced apoptosis.

View Article and Find Full Text PDF

We propose a quantitative phase imaging system with exact slightly-off-axis configuration and suitable for objects both smaller and larger than the size of the effective recording region of the image sensors. In this system, the object is illuminated by a convergent spherical beam and a specially designed aperture filter is placed on the spatial frequency plane of the object wave; at the same time, a point source emitting from the edge of the aperture is taken as the reference beam, so that the optimal frequency condition for reconstruction of slightly-off-axis digital holograms can be always guaranteed for both large and small objects as well as different magnification (or the field of view) configurations. At the same time, a 1x2 single-mode optical fiber splitter is used for generating the reference and the illumination beams.

View Article and Find Full Text PDF

We propose a double-channel angular-multiplexing polarization holographic imaging system with common-path and off-axis configurations. In the system, its input plane is spatially divided into three windows: an object window and two reference windows, and two orthogonal linear polarizers are attached, respectively, on the two reference windows; a two-dimensional cross grating is inserted between the input and output planes of the system. Thus the object beam passing through the object window and the two orthogonal polarized reference beams passing through the two reference windows can overlap each other at the output plane of the system and form a double-channel angular-multiplexing polarization hologram (DC-AM-PH).

View Article and Find Full Text PDF

A time-resolved holographic polarization microscopy, based on angular multiplexing holographic technique, is proposed for imaging ultrafast phenomena in polarization-sensitive transparent materials. This method can retrieve and image the complex amplitude distributions of two orthogonal polarization components of two sequential vector wavefronts with ultrashort time interval by a single short recording. Some experimental results for imaging the pulse laser induced ultrafast events based on the method are given.

View Article and Find Full Text PDF

Objective: To evaluate CT and histopathologic features of lung adenocarcinoma with pure ground-glass nodule (pGGN) ≤10 mm in diameter.

Methods: CT appearances of 148 patients (150 lesions) who underwent curative resection of lung adenocarcinoma with pGGN ≤10 mm (25 atypical adenomatous hyperplasias, 42 adenocarcinoma in situs, 38 minimally invasive adenocarcinomas, and 45 invasive pulmonary adenocarcinomas) were analyzed for lesion size, density, bubble-like sign, air bronchogram, vessel changes, margin, and tumour-lung interface. CT characteristics were compared among different histopathologic subtypes.

View Article and Find Full Text PDF

A wavefront sensing method based on a spatial light modulator (SLM) and an incremental binary random sampling (IBRS) algorithm is proposed. In this method, the recording setup is built just by a transmittance SLM and an image sensor. The tested wavefront incident to the SLM plane can be quantitatively retrieved from the diffraction intensities of the wavefront passed through the SLM displaying a IBRS pattern.

View Article and Find Full Text PDF

Background: Mutations in the Cu/Zn superoxide dismutase () gene have been linked to amyotrophic lateral sclerosis (ALS). However, the molecular mechanisms have not been elucidated yet. Homer family protein Homer1b/c is expressed widely in the central nervous system and plays important roles in neurological diseases.

View Article and Find Full Text PDF

Objective To explore the risk factors of the progression of persistent pure ground-glass nodule (pGGN) and make the risk stratification for pGGN 10 mm or less in diameter. Methods From June 2008 to April 2015,100 patients (108 lesions) with persistent pGGN≤10 mm in diameter were included in this study. Patients were followed up at least 1 year using thin-section computed tomography (CT).

View Article and Find Full Text PDF

Objective: To investigate the correlations between vessel changes and the histopathologic subtypes of lung adenocarcinoma with pure ground-glass nodule (pGGN) on computed tomography (CT).

Methods: Totally 107 patients (116 lesions) with lung adenocarcinomas with pGGN who had undergone curative resection were included. Vessel changes included vascular convergence and/or vessel dilation or distortion within the pGGN.

View Article and Find Full Text PDF

We proposed an iterative method for phase retrieval and diffractive imaging based on Babinet's principle and complementary random sampling (CRS). We demonstrated that the whole complex amplitude (not sieved) of an object wave can be accurately retrieved from the diffraction intensities of the object wave sampled by a group of binary CRS masks and the diffractive imaging for the object can be realized through a single digital inverse diffraction. Some experimental results are given for the demonstration.

View Article and Find Full Text PDF

A simple and practical system for generation of vector beams with arbitrary polarization and complex-amplitude distributions is proposed. The system mainly consists of a scalar computer-generated hologram (CGH), a small-angle birefringent beam splitter (BBS), and a Fourier lens with a filtering aperture (FA). The CGH is placed in front of the Fourier lens.

View Article and Find Full Text PDF

Objective: To discuss the correlation of pathologic subtypes and immunohistochemical implication with CT features of lung adenocarcinoma 1 cm or less in diameter with focal ground-glass opacity (fGGO).

Methods: CT appearances of 59 patients who underwent curative resection of lung adenocarcinoma ≤ 1 cm with fGGO were analyzed in terms of lesion location, size, density, shape (round, oval, polygonal, irregular), margin (smooth, lobular, spiculated, lobular and spiculated), bubble-like sign, air bronchogram, pleural tag, and tumor-lung interface. Histopathologic subtypes were classified according to International Association for the Study of Lung Cancer/ American Thoracic Society/European Respiratory Society classification of lung adenocarcinoma.

View Article and Find Full Text PDF

The evolutionary and statistical properties of the optical vortices that exist in random nondiffracting beams (RNDBs) are analyzed. It is found that the phase singularities (PSs) in the RNDBs originate from the zero rings of Bessel beams with the same ring-shaped spatial spectrum structure (but with zero phase fluctuations) as those of the RNDBs provided. It is also found that the average PS density or vortex density is determined by the average duration of the zero rings of the corresponding Bessel function.

View Article and Find Full Text PDF

Objective: Nance-Horan syndrome (NHS) is a rare X-linked disorder characterized by congenital nuclear cataracts, dental anomalies, and craniofacial dysmorphisms. Mental retardation was present in about 30% of the reported cases. The purpose of this study was to investigate the genetic and clinical features of NHS in a Chinese family.

View Article and Find Full Text PDF

Objective: To observe the effects of navel-warming therapy on clinical efficacy in patients with yang-deficiency tympanites based on regular treatment of western medication.

Methods: One hundred and twenty cases of yang-deficiency tympanites were randomly divided into a navel-warming therapy group and a western medication group, sixty cases in each one. The regular treatment of western medicine was applied in the western medication group, including oral administration of antiviral drug and diuretics as well as intravenous drip of hepatic protector.

View Article and Find Full Text PDF

We analyze the diffraction of the picture obtained by the subtraction of two in-line holograms recorded in two planes at distances of z and z+Deltaz apart from the object plane. Our theoretical analysis reveals that the reconstructed field at the object plane is approximately equal to the Laplacian second-order differentiation of the object wave in transverse direction when Deltaz is much smaller than the distance z, that is, the reconstructed image presents a high quality of edge enhancement. We further investigate the dependence of the edge-enhancement quality on the longitudinal differential distance Deltaz and find that the reconstructed images have the sharpest edge-enhancement and high signal-to-noise ratio at the same time only when the value of Deltaz/z lies between 0.

View Article and Find Full Text PDF