In this work, a novel composite anode material was developed, utilizing S-doped graphene oxide (SGO), polypyrrole (PPy), and fumed silica to enhance the performance of lithium-ion batteries (LIBs). The chronoamperometric approach was used to produce SGO, while the chemical method was employed to synthesize PPy. A composite of SGO, PPy, and fumed silica was prepared as an anode for a half-cell, using two samples: one with a high PPy ratio (S1) and the other with a low PPy ratio (S2) and compared the results with bare sample (S0).
View Article and Find Full Text PDFObjective: The purpose of this study was to compare fresh and frozen-thawed euploid blastocyst transfer protocols following preimplantation genetic screening (PGS) in cases of advanced maternal age.
Methods: A total of 330 patients were examined retrospectively. PGS was performed on the embryos of 146 patients for whom fresh transfers were chosen.
In the present work, a novel electrochemical DNA sensor was designed to detect L. monocytogenes. Two different gene fragments were selected for the sensor design.
View Article and Find Full Text PDFIn recent years, tridentate nitrogen donor ligands have played a vital role in inorganic chemistry. The ease of synthesis, readily modifiable structure and high stability of 1,3-bis(2-pyridylimino)isoindole (BPIs) compounds make them suitable candidates for many potential applications. In this study, a 1,3-bis(2-pyridylimino)isoindoline derivative bearing a naphthoxy unit and its palladium complex (PdBPI) were synthesized and characterized by single crystal X-ray diffraction, NMR, FT-IR, UV-Vis, and mass spectroscopic methods.
View Article and Find Full Text PDFPurpose: This study aimed to investigate which patient and cycle characteristics may affect the number of mature oocytes and cryopreservable blastocysts in the GnRH analog trigger cases.
Methods: This was a retrospective cohort study of 2749 GnRHa trigger cycles in patients at risk of OHSS, including a group of PGT patients, between 2011 and 2020 at Istanbul Memorial Hospital, ART and Reproductive Genetics Center. Patient and cycle characteristics were evaluated using the Generalized Linear Mixed Model (GLMM).
Purpose: To evaluate whether preimplantation genetic testing for aneuploidy (PGT-A) is beneficial for patients who have only one blastocyst available for biopsy or transfer.
Methods: This retrospective study was based on 1126 single blastocyst PGT-A and 938 non-PGT-A cycles, a total of 2064 ART cycles which resulted in a single good quality blastocyst in women between 20 and 45 years old. The PGT-A group had 225 single euploid embryo transfer cycles and the non-PGT-A group had 938 single blastocyst embryo transfer cycles.
This article describes three novel electrochemical biosensing platforms developed to determine the severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) spike antigen protein: glutaraldehyde, SARS-CoV-2 spike antibody and bovine serum albumin; ,-dicyclohexyl carbodiimide/4-(dimethylamino)pyridine functionalised SARS-CoV-2 spike antibody and bovine serum albumin; and 1-ethyl-3-[3-dimethylaminopropyl]-carbodiimide hydrochloride/-hydroxysuccinimide functionalised SARS-CoV-2 spike antibody and bovine serum albumin modified cysteine-based gold-flower modified glassy carbon electrodes. Two of the produced biosensors having better signals were used to determine the SARS-CoV-2 spike antigen in spiked-saliva and clinical samples containing gargle and mouthwash liquids and characterised using cyclic voltammetry, scanning electron microscopy, energy dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy. The study provides highly significant information in terms of how coupling reagents ought to be used with linkers consisting of both amine and carboxylic acid terminals ( cysteine).
View Article and Find Full Text PDFIn this study, the one-step electrochemical preparation of chlorine doped and chlorine-oxygen containing functional group doped graphene-based powders was carried out by Yucel's method, with the resultant materials used as anode materials for lithium (Li)-ion batteries. Cl atoms and ClO ( = 2, 3 or 4) groups, confirmed by X-ray photoelectron spectroscopy analysis, were covalently doped into the graphene powder network to increase the defect density in the graphene framework and improve the electrochemical performance of Li-ion batteries. The microscopic properties of the Cl-doped graphene powder were investigated by scanning electron microscopy and transmission electron microscopy (TEM) analyses.
View Article and Find Full Text PDFGraphene is a material with various application potentials Graphene is a unique material with superiorities and has been applied in various fields for different purposes. Although studies on the utility of graphene oxide in the biomedical field are available, no evaluation has yet been done regarding the utility of sulfur doped (S-doped) graphene. The study focuses on the effect of blending the poly (3-hydroxybutyrate-co-3-hydroxyhexanoate) (PHBHHx) membrane with sulfur heteroatom doped graphene and the evaluation of biological responses to S-doped graphene/PHBHHx.
View Article and Find Full Text PDFBMC Pregnancy Childbirth
February 2021
Background: Before 2010, there were no regulations in Turkey regarding the number of embryos to be transferred in one cycle. In March 2010, regulations restricting this number were implemented by the Turkish Ministry of Health. These specify the transfer of a maximum of one embryo in the first and second cycles and a maximum of two embryos in subsequent cycles in women aged < 35, and a maximum of two embryos in women aged ≥35 in any one cycle.
View Article and Find Full Text PDFPurpose: There is no consensus yet in the literature on an optimal luteinizing hormone (LH) level for human chorionic gonadotrophin (hCG) trigger timing in patients undergoing frozen-thawed embryo transfer (FET) with modified natural cycles (mNC). The objective of our study was to compare the clinical results of hCG trigger at different LH levels in mNC-FET cases.
Methods: This retrospective study was conducted in Istanbul Memorial Hospital ART and Genetics Center.
Purpose: The aim of our study was to evaluate the impact of severe male infertility (SMF) on the chromosomal status of embryos and any possible correlation between chromosomal status and embryo morphokinetics in younger women using data obtained from comprehensive preimplantation genetic tests.
Methods: The trial was conducted in an ART and Reproductive Genetics Centre between 2011 and 2018. A total of 326 cycles in cases with SMF where the female partner's age was ≤ 35 years were evaluated.
Purpose: To conduct a non-inferiority study to compare the clinical outcomes of transdermal estrogen patch and oral estrogen in patients undergoing frozen-thawed single blastocyst transfer non-donor cycles without GnRHagonist (GnRHa) suppression.
Methods: A total of 317 women with irregular menses or anovulatory cycle undergoing frozen-thawed embryo transfer (FET) non-donor cycles without GnRHa suppression were involved in a prospective randomized clinical trial between May 2017 and October 2017. The trial was conducted in an ART and Reproductive Genetics Centre within a private hospital.
Recently, designed platelet shaped micron particles that are composed of nano primary particles, called MicNo (=Micron+naNo) particles, have been developed to exploit the benefits of nano size, while removing the adverse effects of nanoparticles. It has been shown that MicNo-ZnO particles exhibit both micron and nanosized particle characteristics. Although physical and chemical properties of MicNo-ZnO particles have been studied, their biocompatibility has not yet been evaluated.
View Article and Find Full Text PDFA simple and rapid analytical method of determining Pb and Cd in water samples using an electrochemically pretreated pencil-graphite electrode (EP-PGE) is proposed for the first time in the literature. An electrochemically pretreated pencil-graphite electrode was prepared by performing potential cycling between -0.3 V and 2.
View Article and Find Full Text PDFThe removal of organophosphorous insecticide azinphos-methyl (AZPM) from water has been investigated by the electro-Fenton method which produces hydroxyl radicals electro-catalytically. The reaction between these radicals and AZPM has led to the oxidation of AZPM up to carbon dioxide and inorganic ions indicating its complete removal from water. The oxidation kinetics was fitted to pseudo-first order reaction and absolute rate constant of the second order reaction kinetic was determined as (6.
View Article and Find Full Text PDFIn this study, a novel method was proposed for the selective determination of tryptophan (TRP) in blood serum in the presence of tyrosine. This method is based on the electrochemical reduction of 2-amino-3-(5-oxo-3,5-dihydro-2H-indol-3-yl)-propionic acid (5-O-3,5DH-TRP) formed by the oxidation of TRP on the electrochemically treated pencil graphite (ETPG) electrode surface at a suitable potential value. The parameters affecting the TRP determination were deeply investigated.
View Article and Find Full Text PDFDetermination of oxidant stress in plasma of rheumatoid arthritis (RA) and primary osteoarthritis (POA) patients is important in understanding the pathogenesis of these diseases. In this study, we examined the relationship between oxidant stress and inflammation by measuring protein carbonyl content, thiol levels and plasma protein fractions as the oxidation markers and erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) tests as inflammation markers. Protein carbonyls content was higher in RA and POA patients, as compared to controls (p<0.
View Article and Find Full Text PDFA novel approach was proposed for the simple and rapid electrochemical determination of paracetamol (PC) in the presence of uric acid in body fluids. The voltammetric determination of PC is based on the electrochemical reduction of N-acetyl-p-benzoquinoneimine formed simultaneously on the electrochemically treated pencil graphite (ETPG) electrode during the measurement. ETPG electrodes were prepared by the potential cycling between -0.
View Article and Find Full Text PDFA total of 25 patients undergoing coronary artery bypass grafting (CABG) were included in the study. Patients received statin (20 mg daily) postoperatively for 2 weeks. All analyses were performed at 2 different time points: preoperatively (group 1) and 2 weeks after operation (group 2).
View Article and Find Full Text PDFIn this study, the preparation of electrochemically treated pencil graphite (ETPG) electrodes in the mixture of lithium perchlorate and sodium carbonate solutions was investigated for the first time in the literature. The prepared ETPG electrodes showed high selectivity and sensitivity for uric acid (UA) oxidation over ascorbic acid and dopamine. Differential pulse voltammetry (DPV) was used as electrochemical method.
View Article and Find Full Text PDFBiosens Bioelectron
August 2009
A potentiometric detector, based on electrodeposition of polypyrrole onto Pt electrode, was investigated in this study. The chromatographic performance of the PPy detector was investigated in ion chromatography. The resulting PPy detector exhibited good performance for AA determination with a wide linear range (1.
View Article and Find Full Text PDFIn this work, preparation of a molecularly imprinted polymer (MIP) film and its recognition properties for sulfamethoxazolewere investigated. The overoxidized polypyrrole (OPPy) film was prepared by the cyclic voltammetric deposition of pyrrole (Py) in the presence of supporting electrolyte (tetrabutylammonium perchlorate-TBAP) with and without a template molecule (sulfamethoxazole) on a pencil graphite electrode (PGE). The voltammetric behaviour of sulfamethoxazole on imprinted and non-imprinted (NIP) films was investigated by differential pulse voltammetry (DPV) in Britton-Robinson (BR) buffer solutions prepared in different ratio of acetonitrile-water binary mixture, between the pH 1.
View Article and Find Full Text PDFA method for the extraction and selective determination of cations is proposed using electro-synthesized overoxidized sulfonated polypyrrole film. The polymer film is used for the selective extraction of trace levels of nickel and cadmium ions by solid-phase microextraction (SPME). The cation uptake and release properties of the overoxidized sulfonated polypyrrole film electrode were examined under both open circuit and controlled potential conditions for prospective applications in electrochemically controlled solid-phase microextraction.
View Article and Find Full Text PDF