Am J Clin Pathol
September 2024
Spin-orbit interactions arise whenever the bulk inversion symmetry and/or structural inversion symmetry of a crystal is broken providing a bridge between a qubit's spin and orbital degree of freedom. While strong interactions can facilitate fast qubit operations by all-electrical control, they also provide a mechanism to couple charge noise thereby limiting qubit lifetimes. Previously believed to be negligible in bulk silicon, recent silicon nano-electronic devices have shown larger than bulk spin-orbit coupling strengths from Dresselhaus and Rashba couplings.
View Article and Find Full Text PDFBackground And Objectives: The Writing Committee of American Society for Apheresis released the ninth edition of guidelines for therapeutic apheresis in 2023. Categories have been a part of the guidelines since the first edition, and the grading system was introduced in the fifth edition, with updates in every new edition. In this study, we investigated the category and grade change trends through the latest five editions, focusing on therapeutic plasma exchange, to suggest future directions as part of evidence-based medicine.
View Article and Find Full Text PDFBackground: Accurate determination of microsatellite instability (MSI) status is critical for optimal treatment in cancer patients. Conventional MSI markers can sometimes display subtle shifts that are difficult to interpret, especially in non-colorectal cases. We evaluated an experimental eight marker-panel including long mononucleotide repeat (LMR) markers for detection of MSI.
View Article and Find Full Text PDFUniversal quantum computing requires fast single- and two-qubit gates with individual qubit addressability to minimize decoherence errors during processor operation. Electron spin qubits using individual phosphorus donor atoms in silicon have demonstrated long coherence times with high fidelities, providing an attractive platform for scalable quantum computing. While individual qubit addressability has been demonstrated by controlling the hyperfine interaction between the electron and nuclear wave function in a global magnetic field, the small hyperfine Stark coefficient of 0.
View Article and Find Full Text PDFTransfus Apher Sci
October 2023
Introduction: The unexpected antibody test is an essential for ensuring the safety of blood transfusions. In infants, different pre-transfusion tests and transfusion strategies are needed due to their immature antigen/antibody system. This study aims to analyze the pattern of unexpected antibodies and their clinical significance in infants.
View Article and Find Full Text PDFPrevious studies on the immunogenicity of blood group antigens have utilized a formula incorporating antigen frequencies and relative frequencies of unexpected antibodies to the corresponding antigens. This study was aimed at investigating other variables potentially affecting the estimation of immunogenicity using this formula. We examined the effect of multiple transfusions, as there are more chance for a recipient to receive repeated transfusions rather than only once; the effect of antigen density, which may vary depending on homozygote/heterozygote; and the effect of unreliability of the observed frequency of rare antibodies and antigens.
View Article and Find Full Text PDFBackground: The immunogenicity of a blood group antigen is a measure of its likelihood of inducing alloantibodies. Although the immunogenicity of blood group antigens has been analyzed in Caucasian populations, immunogenicity to date has not been analyzed in Asian subjects. The present study therefore evaluated the relative immunogenicity of blood group antigens in a Korean population.
View Article and Find Full Text PDFState preparation and measurement of single-electron spin qubits typically rely on spin-to-charge conversion where a spin-dependent charge transition of the electron is detected by a coupled charge sensor. For high-fidelity, fast readout, this process requires that the qubit energy is much larger than the temperature of the system limiting the temperature range for measurements. Here, we demonstrate an initialization and measurement technique that involves voltage ramps rather than static voltages allowing us to achieve state-to-charge readout fidelities above 99% for qubit energies almost half that required by traditional methods.
View Article and Find Full Text PDFKorean J Transplant
June 2022
The accurate measurement of ABO antibodies is essential for successful ABO-incompatible solid organ transplantation. Titration using two-fold dilution is considered a standard method and is applied in most laboratories. However, this titration method has inherent limitations, including differences in methods between laboratories, a lack of standardization, its semiquantitative nature, and the difficulty of considering the results to be representative of the activity of ABO antibodies.
View Article and Find Full Text PDFBackground and objectives: The ABO antibody (Ab) titration tests are used in monitoring in ABO-incompatible (ABOi) solid organ transplantation (SOT). However, currently developed ABO Ab tests show Ab binding reactions. This study attempted to measure ABO Ab level using complement-dependent cytotoxicity (CDC).
View Article and Find Full Text PDFABO antibodies occur naturally and usually exist as alloantibodies. They are the most clinically significant in cases of transfusions. However, there are very few reports on auto-anti-A or B.
View Article and Find Full Text PDFThe reticulocyte hemoglobin content and hypochromic erythrocyte percentage offer advantages in evaluation of iron deficiency, especially in inflammatory conditions. The aim of this study was to evaluate the correlation of reticulocyte hemoglobin content (CHr, Ret-He) and hypochromic erythrocyte percentage (%HYPO, Hypo-He) between two automated hematologic analyzers. The CHr and %HYPO values were determined using the Advia 2021i (Siemens), while the Ret-He and Hypo-He levels were assessed using the XN-3000 (Sysmex).
View Article and Find Full Text PDFObjective: We compared the clinical outcomes of recipients of ABO-incompatible (ABOi) kidney transplantation (KT) according to the blood group of the plasma transfused.
Materials And Methods: We retrospectively analyzed the data of 60 recipients of ABOi-KT with blood type O and A or B donors. Demographic and clinical characteristics were compared between 2 groups of recipients: 1 group received AB plasma regardless of the donor's blood type (n = 30), and the other group received donor-type plasma (n = 30).
Multiplex nucleic acid amplification assays that simultaneously detect multiple respiratory pathogens in a single nasopharyngeal swab (NPS) specimen are widely used for rapid clinical diagnostics. We evaluated Allplex Respiratory Panel (RP) 1, 2, 3, and the BioFire FilmArray RP assay for detecting respiratory pathogens from NPS specimens. In all, 181 NPS specimens obtained from patients suspected of having respiratory infections during the non-influenza season (August-December 2019) were included.
View Article and Find Full Text PDFBackground: To ensure safe red blood cell (RBC) transfusion practice, it is important to comply with storage and transport requirements of RBC units. We conducted a comprehensive survey on the practice of RBC transport and storage to explore the awareness of and compliance with the 30-minute rule, the current status of RBC unit transport, and possible utility of temperature indicators (TIs) to reduce RBC wastage.
Methods: From June to August of 2019, 64 blood bank physicians (14 questions) in 64 secondary- and tertiary-care hospitals and 673 nurses (13 questions) in 42 tertiary-care hospitals replied to a questionnaire survey.
A requirement for quantum information processors is the in situ tunability of the tunnel rates and the exchange interaction energy within the device. The large energy level separation for atom qubits in silicon is well suited for qubit operation but limits device tunability using in-plane gate architectures, requiring vertically separated top-gates to control tunnelling within the device. In this paper, we address control of the simplest tunnelling device in Si:P, the tunnel junction.
View Article and Find Full Text PDFMatrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been widely used for microbial identification, because of its speed and accuracy, since its introduction to clinical microbiology laboratories. In this study, we evaluated the performance of ASTA MicroIDSys, a newly developed MALDI-TOF, and compared it with the widely used Bruker Biotyper. Microbial identification with the Bruker Biotyper system was performed by using a direct smear method and the Bruker Biotyper database (reference library version 6.
View Article and Find Full Text PDF