Purpose: It remains unclear if fluid pressures used during cataract surgeries contribute to iatrogenic corneal endothelial cell (CEC) loss.
Methods: A custom experimental platform was used to pressurize the anterior chamber of explanted porcine eyes to surgical fluid pressures of 60 mm Hg or 400 mm Hg for 5 minutes or 60 mm Hg for 45 minutes (n = 8 or 9 per group). The corneal endothelia were stained with a unique combination of nucleic acid viability dyes and were imaged using fluorescence microscopy without removing the cornea from the globe.
J Cataract Refract Surg
January 2022
Purpose: To assess the phacoemulsification learning curve for ophthalmology residents using duration for each step.
Setting: Single tertiary, training site hospital.
Design: Cross-sectional study.
Background: This study assessed the impact of distance cataract surgical wet laboratory training on surgical competency of ophthalmology residents at a tertiary-level ophthalmic training center in Trujillo, Peru.
Methods: Three five-week distance wet lab courses were administered through Cybersight, Orbis International's telemedicine platform. Weekly lectures and demonstrations addressed specific steps in phacoemulsification surgery.
J Acad Ophthalmol (2017)
July 2020
Background: The novel coronavirus disease (COVID-19) has created obstacles for medical student education, as clinical rotations were temporarily halted. Recent literature shows online electives may provide an alternative learning platform. We developed a tele-ophthalmology student elective for rising third-year (MS3) and fourth-year (MS4) medical students to continue teaching and exposure to the field.
View Article and Find Full Text PDFPurpose: To test the antiseptic efficacy of povidone-iodine when mixed with topical lidocaine gel.
Setting: Emory School of Medicine, Atlanta, Georgia, USA.
Design: Experimental study.
Purpose: To describe the ethical attitudes of corneal surgeons and eye bank leadership toward for-profit entities in corneal donation, processing, and distribution.
Methods: Fifty postfellowship corneal surgeons practicing in the United States and 25 eye bank leaders (eg, eye bank directors, CEOs, or presidents) for the Eye Bank Association of America-accredited eye banks completed a 22-question interview, focusing on corneal donation industry changes, including the entry of for-profit institutions.
Results: Most participants in both study groups agreed that they have concerns with the entry of for-profit businesses into eye banking (62% corneal surgeons, 68% eye bank leadership), although physicians partnered with a for-profit corneal processor were significantly more likely to have no concerns with the entry of for-profits into eye banking than corneal surgeons partnered with a nonprofit processor (P = 0.
IEEE Trans Ultrason Ferroelectr Freq Control
February 2020
Ultrasound imaging using a matrix array allows real-time multi-planar volumetric imaging. To enhance image quality, the matrix array should provide fast volumetric ultrasound imaging with spatially consistent focusing in the lateral and elevational directions. However, because of the significantly increased data size, dealing with massive and continuous data acquisition is a significant challenge.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
March 2020
Abnormalities in pupillary light reflex can indicate optic nerve disorders that may lead to permanent visual loss if not diagnosed in an early stage. In this study, we focus on relative afferent pupillary defect (RAPD), which is based on the difference between the reactions of the eyes when they are exposed to light stimuli. Incumbent RAPD assessment methods are based on subjective practices that can lead to unreliable measurements.
View Article and Find Full Text PDFImportance: Rear-facing sideview mirrors are a potentially reducible source of ocular morbidity following motor vehicle crashes.
Objective: To report cases highlighting shattered glass from sideview mirrors as a potential cause of ocular trauma in motor vehicle crashes.
Design, Setting, And Participants: Case series of 3 patients who presented to Grady Memorial Hospital, a level 1 trauma center and tertiary hospital, between May 5, 2017, and July 10, 2017, with ocular trauma as a result of shattered glass from sideview mirrors during motor vehicle crashes.
The aim of this study was to assess the current state of automated pupillometry technology and its application in the neurointensive care unit (neuroICU). We performed a literature search using the PubMed, MEDLINE, and EMBASE databases from database inception through a search end date of October 18, 2018, to identify studies reporting on the use of automated pupillometry in the care of critically ill patients with neurological impairment. Two independent reviewers reviewed all titles and abstracts in two filtering phases.
View Article and Find Full Text PDFCorneal endothelial cell (CEC) loss occurs from tissue manipulation during anterior segment surgery and corneal transplantation as well as from contact with synthetic materials like intraocular lenses and tube shunts. While several studies have quantified CEC loss for specific surgical steps, the vulnerability of CECs to isolated, controllable and measurable mechanical forces has not been assessed previously. The purpose of this study was to develop an experimental testing platform where the susceptibility of CECs to controlled mechanical trauma could be measured.
View Article and Find Full Text PDFUnlabelled: Purpose/Aim: Despite their importance in accurate mechanical modeling of the cornea, the depth-dependent material properties of the cornea have only been partially elucidated. In this work, we characterized the depth-dependent out-of-plane Young's modulus of the central and peripheral human cornea with high spatial resolution.
Materials And Methods: Central and peripheral corneal buttons from human donors were subjected to unconfined axial compression followed by stress relaxation for 30 min.
Purpose: To evaluate the accuracy of eye bank-prepared precut donor corneas over time by comparing cut-failure rates and corneal thickness measurements in 2010 and 2013.
Methods: A total of 2511 human corneas cut by a technician-operated mechanical microkeratome intended for endothelial keratoplasty were evaluated prospectively at one large eye bank facility in 2010 and in 2013. The endothelium was evaluated by slit lamp, and specular microscopy both before and after cutting was performed.
Purpose: To compare 8 ophthalmology resident surgical training tools to determine which is most cost effective.
Setting: University of Rochester Medical Center, Rochester, New York, USA.
Design: Retrospective evaluation of technology.
Invest Ophthalmol Vis Sci
October 2014
Purpose: To characterize the depth-dependent shear modulus of the central and peripheral human cornea along the superior-inferior and nasal-temporal directions with a high spatial resolution.
Methods: Cylindrical explants from the central and peripheral corneas of 10 human donors were subjected to a 5% shear strain along the superior-inferior and nasal-temporal directions using a microscope-mounted mechanical testing device. Depth-dependent shear strain and shear modulus were computed through force measurements and displacement tracking.
Purpose: The aim of this study was to analyze Descemet stripping automated endothelial keratoplasty donor endothelial grafts, prepared by using a microkeratome, in terms of uniformity, circularity, and concentricity.
Methods: In this pilot study, 12 human donor corneas were prepared by means of a microkeratome and imaged using the Visante anterior segment optical coherence tomography along 4 meridians. The microkeratome enters and exits the corneal tissue at an angle, creating a donor graft bed with a uniform stromal (US) thickness in between the angled edges.
Clin Ophthalmol
November 2012
A 64-year-old Caucasian male complaining of redness and tearing for 3 years in both eyes was referred for evaluation of cicatricial conjunctivitis. Ocular cicatricial pemphigoid was suspected and this diagnosis was confirmed through biopsy. The patient's condition showed moderate improvement following treatment with methotrexate and mycophenolate mofetil.
View Article and Find Full Text PDF