Electron capture dissociation (ECD) of polypeptide cations was obtained with pencil and hollow electron beams for both sidekick and gas-assisted dynamic ion trapping (GADT) using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) with an electrostatic ion transfer line. Increasing the number of trapped ions by multiple ICR trap loads using GADT improved the ECD sensitivity in comparison with sidekick ion trapping and ECD efficiency in comparison with single ion trap load by GADT. Furthermore, enhanced sensitivity made it possible to observe ECD in a wide range of electron energies (0-50 eV).
View Article and Find Full Text PDFThe analytical utility of the electron capture dissociation (ECD) technique, developed by McLafferty and co-workers, has substantially improved peptide and protein characterization using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The limitations of the first ECD implementations on commercial instruments were eliminated by the employment of low-energy electron-injection systems based on indirectly heated dispenser cathodes. In particular, the ECD rate and reliability were greatly increased, enabling the combination of ECD/FTICR-MS with on-line liquid separation techniques.
View Article and Find Full Text PDFThe present paper suggests a new algorithm for estimation of peak positions in FTMS spectra. It is shown theoretically and experimentally that the new technique yields superior results compared to the currently applied techniques, when the noise level is high and/or the peaks are located close to each other. Cases are presented where the deviation from the true mass could be mistaken for space charge effect, while the shift is in fact solely due to the shortcomings of the current techniques and can be corrected by applying the shifted-basis technique.
View Article and Find Full Text PDFAn electron injection system based on an indirectly heated ring-shaped dispenser cathode has been developed and installed in a 7 Tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. This new hardware design allows high-rate electron capture dissociation (ECD) to be carried out by a hollow electron beam coaxial with the ion cyclotron resonance (ICR) trap. Infrared multiphoton dissociation (IRMPD) can also be performed with an on-axis IR-laser beam passing through a hole at the centre of the dispenser cathode.
View Article and Find Full Text PDFLiquid chromatography mass spectrometry (LC-MS) is a valuable tool in the analysis of proteins and peptides. The combination of LC-MS with different fragmentation methods provides sequence information on components in complex mixtures. In this work, on-line packed capillary LC electrospray ionization Fourier transform ion cyclotron resonance MS was combined with two complementary fragmentation techniques, i.
View Article and Find Full Text PDFIonization energies (IE) of [M + zH](z+) (z+) electrospray-produced polypeptides were determined by electron ionization in a Penning cell of 4.7 and 9.4 T Fourier transform mass spectrometers.
View Article and Find Full Text PDFLiquid separation methods in combination with electrospray mass spectrometry as well as the recently introduced fragmentation method electron capture dissociation (ECD) have become powerful tools in proteomics research. This paper presents the results of the first successful attempts to combine liquid chromatography (LC) and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with ECD in the analysis of a mixture of standard peptides and of a bovine serum albumin tryptic digest. A novel electron injection system provided conditions for ECD sufficient to yield extensive sequence information for the most abundant peptides in the mixtures on the time-scale of the chromatographic separation.