Publications by authors named "Youngjae Chun"

Objective: Aneurysm pathophysiology remains poorly understood, in part from the disparity of murine models with human physiology and the requirement for invasive aortic exposure to apply agents used to create aneurysm models. A retrievable drug infusion stent graft (RDIS) was developed to isolate the aortic wall intraluminally for drug exposure. We hypothesized that an RDIS could deliver aneurysm-promoting enzymes to create a porcine model of thoracic aneurysms without major surgical exposure.

View Article and Find Full Text PDF

Objectives: Non-compressible torso hemorrhage remains a high mortality injury, with difficulty mobilizing resources before exsanguination. Previous studies reported on a retrievable stent graft for damage control and morphometric algorithms for rapid placement, yet fluoroscopy is impractical for the austere environment. We hypothesized that magnetic sensors could be used to position stents relative to an external magnet placed on an anatomic landmark, whereas an electromagnet would allow self-calibration to account for environmental noise.

View Article and Find Full Text PDF

Objective: Noncompressible torso hemorrhage is a high-mortality injury. We previously reported improved outcomes with a retrievable rescue stent graft to temporize aortic hemorrhage in a porcine model while maintaining distal perfusion. A limitation was that the original cylindrical stent graft design prohibited simultaneous vascular repair, given the concern for suture ensnarement of the temporary stent.

View Article and Find Full Text PDF

Atherosclerosis is a common cause of coronary artery disease and a significant factor in broader cardiovascular diseases, the leading cause of death. While implantation of a stent is a prevalent treatment of coronary artery disease, a frequent complication is restenosis, where the stented artery narrows and stiffens. Although early detection of restenosis can be achieved by continuous monitoring, no available device offers such capability without surgeries.

View Article and Find Full Text PDF

Cerebral aneurysm embolization is a therapeutic approach to prevent rupture and resultant clinical sequelae. Current, non-biodegradable metallic coils (platinum or tungsten) are the first-line choice to secure cerebral aneurysms. However, clinical studies report that up to 17% of aneurysms recur within 1 year after coiling, leading to retreatment and additional surgery.

View Article and Find Full Text PDF

Background: Noncompressible hemorrhage remains a high-mortality injury, which requires rapid damage control within minutes to avoid exsanguination. Retrievable stent grafts offer perfusion preserving hemorrhage damage control, and yet algorithms for device selection and positioning are lacking for an anatomically diverse human population. We hypothesized that easily acquired external measurements could be used to rapidly triage patients to receive one of several presized stents and that these metrics may further predict a single target on the aorta by which to optimize both mesenteric perfusion and aortic hemorrhage control.

View Article and Find Full Text PDF

Fetal aqueductal stenosis (AS) is one of the most common causes of congenital hydrocephalus, which increases intracranial pressure due to partial or complete obstruction of cerebrospinal fluid (CSF) flow within the ventricular system. Approximately 2-4 infants per 10,000 births develop AS, which leads to progressive hydrocephalus, which enlarges the head often necessitating delivery by cesarean section. Most babies born with AS are severely neurologically impaired and experience a lifetime of disability.

View Article and Find Full Text PDF

To improve the energy efficiency and driving performance of ionic electroactive polymer actuators, we propose inserting insulating layers of 170 nm hexagonal boron nitride (h-BN) particles between the ionic polymer membrane and electrodes. In experiments, actuators exhibited better capacitance (4.020 × 10 F), displacement (6.

View Article and Find Full Text PDF

Shortage of healthy donors' organs has appeared as one of the main challenges for organ transplantation. This study focuses on the novel endovascular device development to increase the number of available organs from cardiac death donors. The primary objective of this study is the design validation of a newly developed stent graft for the abdominal organ perfusion with cardiac blood flow isolation.

View Article and Find Full Text PDF

Background: Ischemic injury during the agonal period of donation after circulatory death donors remains a significant barrier to increasing abdominal transplants. A major obstacle has been the inability to improve visceral perfusion, while at the same time respecting the ethics of the organ donor. A retrievable dual-chamber stentgraft could potentially isolate the organ perfusion from systemic hypotension and hypoxia, without increasing cardiac work or committing the donor.

View Article and Find Full Text PDF

Nitinol is an excellent candidate material for developing various self-expanding endovascular devices due to its unique properties such as superelasticity, biocompatibility and shape memory effect. A low-energy laser joining technique suggests a high potential to create various large diameter Nitinol endovascular devices that contain complex geometries. The primary purpose of the study is to investigate the effects of laser joining process parameters with regard to the mechanical and biocompatible performance of Nitinol stents.

View Article and Find Full Text PDF

Pediatric laryngotracheal stenosis is a complex congenital or acquired airway injury that may manifest into a potentially life-threatening airway emergency condition. Depending on the severity of obstruction, treatment often requires a combination of endoscopic techniques, open surgical repair, intraluminal stenting, or tracheostomy. A balloon expandable biodegradable airway stent maintaining patency while safely degrading over time may address the complications and morbidity issues of existing treatments providing a less invasive and more effective management technique.

View Article and Find Full Text PDF

Background: Noncompressible hemorrhage remains a high-mortality injury, and aortic balloon occlusion poses limitations in terms of distal ischemic injury. Our hypothesis was that a retrievable Rescue stent would confer improved outcome over aortic balloon occlusion.

Methods: A three-tier, retrievable stent graft was laser welded from nitinol and polytetrafluoroethylene to provide rapid thoracic and abdominal coverage with an interval bare metal segment to preserve visceral flow.

View Article and Find Full Text PDF

Traumatic vascular injuries, resulting from either civilian accidents or wounded soldiers, require new endovascular devices (i.e., stent graft) to rapidly control the excessive internal hemorrhage in torso region.

View Article and Find Full Text PDF

We introduce a new tongue prosthetic assist device (TPAD), which shows the first prosthetic application for potential treatment of swallowing difficulty in dysphagia patients. The native tongue has a number of complex movements that are not feasible to mimic using a single mechanical prosthetic device. In order to overcome this challenge, our device has three key features, including (1) a superelastic nitinol structure that transfers the force produced by the jaws during chewing towards the palate, (2) angled composite tubes for guiding the nitinol strips smoothly during the motion, and (3) highly stretchable thin polymeric membrane as a covering sheet in order to secure the food and fluids on top of the TPAD for easy swallowing.

View Article and Find Full Text PDF

: Neurovascular compression syndromes (NVCS) could be cured with an intravascular device that releases compression of the root entry zone of cranial nerves by changing the course of offending vessels. The purpose of this study was to report our results of in vitro and in vivo experiments with a novel intra-arterial neurovascular decompressor (IA-NVD) for NVCS. : A nitinol-based IA-NVD was developed to release pressure applied to the root entry zone of cranial nerves by changing the course or angle of an offending vessel, which can possibly cure NVCS.

View Article and Find Full Text PDF

Customizable medical devices have recently attracted attentions both in dental and orthopedic device fields, which can tailor to the patients' anatomy to reduce the length of surgery time and to improve the clinical outcomes. However, development of the patient specific endovascular device still remains challenging due to the limitations in current 3D printing technology, specifically for the stent grafts. Therefore, our group has investigated the feasibility of a highly stretchable expanded-polytetrafluoroethylene (ePTFE) tube as a customizable graft material with the laser-welded nitinol backbone.

View Article and Find Full Text PDF

Objective: Early hemorrhage control before the operating room is essential to reduce the significant mortality associated with traumatic injuries of the vena cava. Conventional approaches present logistical challenges on the battlefield or in the trauma bay. A retrievable stent graft would allow rapid hemorrhage control in the preoperative setting when endovascular expertise is not immediately available and without committing a patient to the limitations of current permanent stents.

View Article and Find Full Text PDF

Random weakening of an intracranial blood vessel results in abnormal blood flow into an aneurysmal sac. Recent advancements show that an implantable flow diverter, integrated with a medical stent, enables a highly effective treatment of cerebral aneurysms by guiding blood flow into the normal vessel path. None of such treatment systems, however, offers post-treatment monitoring to assess the progress of sac occlusion.

View Article and Find Full Text PDF

Recent wearable devices offer portable monitoring of biopotentials, heart rate, or physical activity, allowing for active management of human health and wellness. Such systems can be inserted in the oral cavity for measuring food intake in regard to controlling eating behavior, directly related to diseases such as hypertension, diabetes, and obesity. However, existing devices using plastic circuit boards and rigid sensors are not ideal for oral insertion.

View Article and Find Full Text PDF

The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes.

View Article and Find Full Text PDF

Percutaneous vertebroplasty procedure is of major importance, given the significantly increasing aging population and the higher number of orthopedic procedures related to vertebral compression fractures. Vertebroplasty is a complex technique involving the injection of polymethylmethacrylate (PMMA) into the compressed vertebral body for mechanical stabilization of the fracture. Our understanding and ability to modify these mechanisms through alterations in cement material is rapidly evolving.

View Article and Find Full Text PDF

Background: Noncompressible hemorrhage of the torso remains a challenging surgical dilemma. Stent graft repair requires endovascular expertise, imaging, and inventory that are not available within the critical window of massive hemorrhage. We developed a retrievable stent graft for rapid hemorrhage.

View Article and Find Full Text PDF

We introduce a skin-friendly electronic system that enables human-computer interaction (HCI) for swallowing training in dysphagia rehabilitation. For an ergonomic HCI, we utilize a soft, highly compliant ("skin-like") electrode, which addresses critical issues of an existing rigid and planar electrode combined with a problematic conductive electrolyte and adhesive pad. The skin-like electrode offers a highly conformal, user-comfortable interaction with the skin for long-term wearable, high-fidelity recording of swallowing electromyograms on the chin.

View Article and Find Full Text PDF

There are more than 3 million people in the world whose mobility relies on wheelchairs. Recent advancement on engineering technology enables more intuitive, easy-to-use rehabilitation systems. A human-machine interface that uses non-invasive, electrophysiological signals can allow a systematic interaction between human and devices; for example, eye movement-based wheelchair control.

View Article and Find Full Text PDF