Publications by authors named "Youngdo Jung"

A human can intuitively perceive and comprehend complicated tactile information because the cutaneous receptors distributed in the fingertip skin receive different tactile stimuli simultaneously and the tactile signals are immediately transmitted to the brain. Although many research groups have attempted to mimic the structure and function of human skin, it remains a challenge to implement human-like tactile perception process inside one system. In this study, we developed a real-time and multimodal tactile system that mimics the function of cutaneous receptors and the transduction of tactile stimuli from receptors to the brain, by using multiple sensors, a signal processing and transmission circuit module, and a signal analysis module.

View Article and Find Full Text PDF

Hierarchical structures in nature provide unique functions for living organisms that can inspire technology. Nanoscale hierarchical structured surfaces are essential to realize the dual functions of non-wetting and transparency for applications such as cover glasses and windows; however, these structures are challenging to fabricate. In this study, nano-hierarchical structured glass surfaces were fabricated using multi-step colloidal lithography and etching to obtain tunable morphology.

View Article and Find Full Text PDF

Sulforaphane (SFN) is a naturally occurring isothiocyanate that is abundant in many cruciferous vegetables, such as broccoli and cauliflower, and it has been observed to exert numerous biological activities. In the present study, we investigate the effect of SFN on eNOS, a key regulatory enzyme of vascular homeostasis and underlying intracellular pathways, in human endothelial EA.hy926 cells.

View Article and Find Full Text PDF

Sulforaphane, a natural phytochemical compound found in various cruciferous vegetables, has been discovered to present anti-cancer properties. Matrix metalloproteinase-9 (MMP-9) plays a crucial role in gastric cancer metastasis. However, the role of sulforaphane in MMP-9 expression in gastric cancer is not yet defined.

View Article and Find Full Text PDF

In order to realize a transition from conventional to stretchable electronics, it is necessary to make a universal stretchable circuit board in which passive/active components can be robustly integrated. We developed a stretchable printed circuit board (s-PCB) platform that enables easy and reliable integration of various electronic components by utilizing a modulus-gradient polymeric substrate, liquid metal amalgam (LMA) circuit traces, and Ag nanowire (AgNW) contact pads. Due to the LMA-AgNW biphasic structure of interconnection, the LMA is hermetically sealed by a homogeneous interface, realizing complete leak-free characteristics.

View Article and Find Full Text PDF

Micro-RNA-21 (miR-21) is a vital regulator of colorectal cancer (CRC) progression and has emerged as a potential therapeutic target in CRC treatment. Our study using real-time PCR assay found that a secondary bile acid, lithocholic acid (LCA), stimulated the expression of miR21 in the CRC cell lines. Promoter activity assay showed that LCA strongly stimulated miR21 promoter activity in HCT116 cells in a time- and dose-dependent manner.

View Article and Find Full Text PDF

Cochlear implants (CIs) have become the standard treatment for severe-to-profound sensorineural hearing loss. Conventional CIs have some challenges, such as the use of extracorporeal devices, and high power consumption for frequency analysis. To overcome these, artificial basilar membranes (ABMs) made of piezoelectric materials have been studied.

View Article and Find Full Text PDF

In this study, a parasitic capacitance-free tactile sensor with a floating electrode that is capable of identifying actual physical contact pressure by distinguishing from parasitic effects and applicable to sensor arrays is presented. Although capacitive pressure sensors are known for their excellent pressure sensing capabilities in wide range with high sensitivity, they tend to suffer from a parasitic capacitance noise and unwanted proximity effects. Electromagnetic interference shielding was conventionally used to prevent this noise; however, it was not entirely successful in multicell array sensors.

View Article and Find Full Text PDF

Slippery liquid-infused porous surfaces (SLIPSs) have been actively studied to improve the limitations of superhydrophobic (SHP) surfaces, especially the defects of the nonwetting chemical coating layer and the weak mechanical robustness of surface micro/nanostructures. However, the SLIPSs also have several drawbacks including volatilization and leakage of lubricant caused by long-term usage. In this study, we suggest the use of icephobic, highly transparent, and self-healing solid slippery surface to overcome the limitations of both surfaces (SLIPS and SHP) by combining specific biomimetic morphology and intrinsic properties of paraffin wax.

View Article and Find Full Text PDF

Durability and multifunctionality are very important factors for human skinlike tactile sensors for measuring physical stimuli if they provide reasonable pressure measurement range and sensitivity. Here, we propose a step tactile sensor with a simple processing unit, showing high repeatability and mechanical stability without drifting caused by thermal and geometrical noise. The proposed sensor, similar to a switch mechanism, detects the applied pressure discretely and has a wide pressure range of 2 kPa to 1.

View Article and Find Full Text PDF

Mechanoreceptors in a fingertip convert external tactile stimulations into electrical signals, which are transmitted by the nervous system through synaptic transmitters and then perceived by the brain with high accuracy and reliability. Inspired by the human synapse system, this paper reports a robust tactile sensing system consisting of a remote touch tip and a magnetic synapse. External pressure on the remote touch tip is transferred in the form of air pressure to the magnetic synapse, where its variation is converted into electrical signals.

View Article and Find Full Text PDF

Several studies have demonstrated a correlation between the expression of early growth response gene-1 (EGR-1) and the progression of gastric cancers at advanced stages. However, the effects of EGR-1 expression on human gastric cancer progression, particularly on precancerous lesions, have not been investigated. In this study, we evaluate EGR-1 expression levels in target mucosa from patients with early gastric cancer and precancerous lesions, and assess whether EGR-1 expression affects the oncogenic phenotypes of human gastric cancer cells.

View Article and Find Full Text PDF

High sensitive flexible and wearable devices which can detect delicate touches have attracted considerable attentions from researchers for various promising applications. This research was aimed at enhancing the sensitivity of a MWCNT/PDMS piezoresistive tactile sensor through modification of its surface texture in the form of micropillars on MWCNT/PDMS film and subsequent low energy Ar⁺ ion beam treatment of the micropillars. The introduction of straight micropillars on the MWCNT/PDMS surface increased the sensitivity under gentle touch.

View Article and Find Full Text PDF

Flexible tactile sensors capable of detecting the magnitude and direction of the applied force together are of great interest for application in human-interactive robots, prosthetics, and bionic arms/feet. Human skin contains excellent tactile sensing elements, mechanoreceptors, which detect their assigned tactile stimuli and transduce them into electrical signals. The transduced signals are transmitted through separated nerve fibers to the central nerve system without complicated signal processing.

View Article and Find Full Text PDF

This paper presents the development of a piezoelectric artificial cochlea (PAC) device capable of analyzing vibratory signal inputs and converting them into electrical signal outputs without an external power source by mimicking the function of human cochlea within an audible frequency range. The PAC consists of an artificial basilar membrane (ABM) part and an implantable packaged part. The packaged part provides a liquid environment through which incoming vibrations are transmitted to the membrane part.

View Article and Find Full Text PDF

Stretchable electronic skins with multidirectional force-sensing capabilities are of great importance in robotics, prosthetics, and rehabilitation devices. Inspired by the interlocked microstructures found in epidermal-dermal ridges in human skin, piezoresistive interlocked microdome arrays are employed for stress-direction-sensitive, stretchable electronic skins. Here we show that these arrays possess highly sensitive detection capability of various mechanical stimuli including normal, shear, stretching, bending, and twisting forces.

View Article and Find Full Text PDF

The development of flexible electronic skins with high sensitivities and multimodal sensing capabilities is of great interest for applications ranging from human healthcare monitoring to robotic skins to prosthetic limbs. Although piezoresistive composite elastomers have shown great promise in this area of research, typically poor sensitivities and low response times, as well as signal drifts with temperature, have prevented further development of these materials in electronic skin applications. Here, we introduce and demonstrate a design of flexible electronic skins based on composite elastomer films that contain interlocked microdome arrays and display giant tunneling piezoresistance.

View Article and Find Full Text PDF

In this research, we have developed a multi-channel piezoelectric acoustic sensor (McPAS) that mimics the function of the natural basilar membrane capable of separating incoming acoustic signals mechanically by their frequency and generating corresponding electrical signals. The McPAS operates without an external energy source and signal processing unit with a vibrating piezoelectric thin film membrane. The shape of the vibrating membrane was chosen to be trapezoidal such that different locations of membrane have different local resonance frequencies.

View Article and Find Full Text PDF

Aims And Background: The aims of the current study were to evaluate whether recepteur d'origine nantais (RON) affects tumor cell behavior and oncogenic signaling pathways in colorectal cancer, and to examine the relationship of its expression with various clinicopathological parameters and patient survival.

Methods: Immunohistochemistry, Western blot and RT-PCR were used to detect the expression of the RON gene in human colorectal cancer tissue. To study the biological role of RON in tumor cell behavior and cellular signaling pathways, we used small interfering RNA (siRNA) to knock down RON gene expression in human colorectal cancer cell lines.

View Article and Find Full Text PDF

The recepteur d'origine nantais (RON) receptor tyrosine kinase is overexpressed in epithelial cancers, including gastric cancer. The aims of the present study were to evaluate whether RON affects tumor cell behaviors and oncogenic signaling pathways, and to document the relationship of its expression with various clinicopathological parameters in gastric cancer. The biological role of RON in tumor cell behaviors and oncogenic signaling pathways was investigated by using small interfering RNA in gastric cancer cell lines including AGS and MKN28.

View Article and Find Full Text PDF

Background/aims: Altered Recepteur d'Origine nantais (RON) expression transduces signals inducting invasive growth phenotype that includes cell proliferation, migration, matrix invasion, and protection of apoptosis in human cancer cells. The aims of the current study were to evaluate whether RON affects tumor cell behavior and cellular signaling pathways including activator protein-1 (AP-1) and Akt/forkhead box O (FoxO) in human colorectal cancer cells.

Methods: To study the biological role of RON on tumor cell behavior and cellular signaling pathways in human colorectal cancer, we used small interfering RNA (siRNA) to knockdown RON gene expression in human colorectal cancer cell line, DKO-1.

View Article and Find Full Text PDF

This paper is focused on the development of a six-stage cascade paramagnetic mode magnetophoretic separation (PMMS) system for separating suspended cells in blood based on their native magnetic properties. The design and fabrication of a PMMS system are presented and the microfluidic separation system is characterized experimentally using human whole blood as the case study. The PMMS system can separate blood cells types continuously using the magnetophoretic force produced from a high magnetic field gradient without magnetic or fluorescent tagging.

View Article and Find Full Text PDF

Purpose: To investigate the efficacy of umbilical cord serum eyedrops for the treatment of severe dry eye syndrome.

Methods: Fifty-five eyes of 31 patients with severe dry eye syndrome were treated with umbilical cord serum eyedrops. Symptom scoring, tear film break-up time (BUT), Schirmer test, corneal sensitivity test, and corneal fluorescein staining were performed before and 1 and 2 months after treatment, and conjunctival impression cytology was performed before and 2 months after treatment.

View Article and Find Full Text PDF