Purpose: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the Bencox® hip stem-the first Korean-developed hip prosthesis.
Materials And Methods: A consecutive series of 1,000 hip arthroplasties using the Bencox® hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84).
Background: Although distal radius fractures (DRF) are common fractures, intra-articular comminuted DRF with volar free fragments are uncommon. There is considerable difficulty in the fixation of free fragments beyond the watershed line using the existing volar locking plate. We aimed to examine the efficacy and potential complications associated with the use of juxta-articular volar plates in intra-articular DRF accompanied by free fragments beyond the watershed line.
View Article and Find Full Text PDFThe original publication of this article [1] contained the wrong versions of tables 1, 2 and 3. In this correction the updated tables are published. The original publication has been updated.
View Article and Find Full Text PDFBackground: Calcaneal insufficiency avulsion (CIA) fractures often present with neuropathic etiology, such as Charcot neuroarthropathy (CN). Under the same surgical procedures, the outcomes of CIA fractures are less desirable, compared to the outcomes of the traumatic calcaneal avulsion fractures. Here, the study suggests Achilles tenodesis technique using suture anchor after resection of the CIA fracture fragments could provide satisfactory clinical results in the cases of surgically indicated CIA fractures.
View Article and Find Full Text PDFPurpose: For patients with metacarpophalangeal (MCP) extensor tendon subluxation caused by finger flicking injury, we performed an extensor tendon realignment and direct repair technique. The purpose of this study was to evaluate the clinical outcome after direct repair of the sagittal band in patients with MCP extensor tendon subluxation caused by finger flicking injury and to introduce the repair technique.
Methods: A total of 26 patients with a mean age of 39.
Introduction: Displaced unstable distal third fractures of the humeral diaphysis are treated surgically through open reduction and internal fixation. Conventionally, surgeons prefer using long plates for secure fixation; however, we performed short plate dual plating for robust fixation that required a smaller incision and less dissection through an anterior approach. In this study, we report the results of dual plating of fractures of the humeral shaft, with radiographic evidence and clinical analysis.
View Article and Find Full Text PDFAlthough Helicobacter pylori infections of the gastric mucosa are characterized by the infiltration of inflammatory cells such as eosinophils, the responses of eosinophils to H. pylori vacuolating cytotoxin (VacA) have not been fully elucidated. This study investigates the role of VacA in the apoptosis of human eosinophils.
View Article and Find Full Text PDFEnterotoxigenic Bacteroides fragilis (ETBF) produces an approximately 20-kDa heat-labile enterotoxin (BFT) that plays an essential role in mucosal inflammation. Although spontaneous disappearance of ETBF infection is common, little information is available on regulated expression of antibacterial factors in response to BFT stimulation. This study investigates the role of BFT in human beta-defensin 2 (hBD-2) induction from intestinal epithelial cells.
View Article and Find Full Text PDFJ Nanosci Nanotechnol
November 2006
Two-dimensional (2-D) and three-dimensional (3-D) diamond-like carbon (DLC) stamps for ultraviolet nanoimprint lithography were fabricated with two methods: namely, a DLC coating process, followed by focused ion beam lithography; and two-photon polymerization patterning, followed by nanoscale-thick DLC coating. We used focused ion beam lithography to fabricate 70 nm deep lines with a width of 100 nm, as well as 70 nm deep lines with a width of 150 nm, on 100 nm thick DLC layers coated on quartz substrates. We also used two-photon polymerization patterning and a DLC coating process to successfully fabricate 200 nm wide lines, as well as 3-D rings with a diameter of 1.
View Article and Find Full Text PDFIn this paper, we fabricated a fluorinated organic-inorganic hybrid mold using a nonhydrolytic sol-gel process which can produce a crack-free mold without leaving any trace of solvent. No special chemical treatment of a release layer is needed because the fluorinated hybrid mold has fluorine molecules in the backbone. The other advantages of the hybrid mold are thermal stability over 300 degrees C.
View Article and Find Full Text PDF