Publications by authors named "Young Wook Lim"

: Recent advancements in hip arthroplasty aim to enhance the stability, longevity, and functionality of femoral implants. However, the distal fitting of femoral stems, often caused by metaphyseal-diaphyseal mismatch, remains a significant issue, particularly in patients with Dorr type A femora. Such mismatches can result in suboptimal implant performance, leading to potential complications.

View Article and Find Full Text PDF

Introduction: A fracture of the ceramic head in bipolar hemiarthroplasty using an inner polyliner has not been reported yet, and there seems to be no report of simultaneous breakage of the fourth-generation BIOLOX Delta ceramic head and liner in total hip arthroplasty.

Method: A 44-year-old male patient underwent bipolar hemiarthroplasty using a third-generation BIOLOX Forte ceramic head 3 years and 9 months earlier for osteonecrosis of femoral head (ONFH) and visited our hospital due to a ceramic head fracture. Conversion total hip arthroplasty was performed.

View Article and Find Full Text PDF

Purpose: Venous thromboembolism (VTE) is a major complication for hip fracture patients, and may exist preoperatively. This study aimed to examine the prevalence of VTE after immediate screening in hip fracture patients.

Materials And Methods: Hip fracture patients with an elevated level of D-dimer underwent screening for VTE using computed tomography (CT) angiography.

View Article and Find Full Text PDF

Purpose: Unlike periprosthetic femoral fractures, periprosthetic acetabular fractures during total hip arthroplasty (THA) have not been evaluated in detail. We prospectively evaluated the incidence, patterns, risk factors, and clinical outcomes of intraoperative periprosthetic acetabular fractures using pre- and postoperative computer tomography (CT).

Methods: In this prospective single-centre study, we evaluated 234 consecutive patients (250 hips) who underwent THA and three-dimensional CT before and after the surgery.

View Article and Find Full Text PDF

Most medical implants are made of titanium. When titanium is exposed to air for a long time, hydrocarbons are deposited and the surface becomes hydrophobic. Cell attachment is important for bone ingrowth to occur on the implant surface, and hydrophilicity can enhance this.

View Article and Find Full Text PDF

Objective: This is a rare study comparing the radiological and functional outcomes of fixation after reduction with in situ fixation group using Femoral Neck System (FNS). The aim of this study was to introduce a simple, innovative, minimally invasive method to reduce valgus-impacted and tilted femoral neck fractures without soft tissue or cartilage injury.

Methods: A retrospective comparative analysis of 46 patients between May 2020 and February 2022 was performed.

View Article and Find Full Text PDF

Background: In revision surgery with significant segmental acetabular defects, adequate implant selection and fixation methods are critical in determining successful bony ingrowth. Commercially available total hip prosthesis manufacturers generally offer additional multi-hole options of acetabular shells with identical designs for use in revision THAs where screw holes configurations vary from product to product. This study aims to compare the mechanical stability of the two types of acetabular screw constructs for the fixation of acetabular components: spread-out and pelvic brim-focused configurations.

View Article and Find Full Text PDF

High-dose bisphosphonate for multiple myeloma patients might elevate risks of skeletal complications earlier than general expectations. This study aims to find incidences of atypical femoral fracture (AFF) and medication-related osteonecrosis of the jaw (MRONJ), elucidate their risk factors, and suggest cut-off values for the safer dosing of high-dose bisphosphonate treatment. By using the clinical data warehouse of a single institute, retrospective cohort data of multiple myeloma-diagnosed patients with high-dose bisphosphonate (pamidronate or zoledronate) treatment from 2009 to 2019 was extracted.

View Article and Find Full Text PDF

Purpose: Osteonecrosis of the femoral head (ONFH) and subsequent head collapse is a major concern after internal fixation of femoral neck fracture (FNF). Previous studies focused on ONFH incidence using plain radiography; postoperative magnetic resonance imaging (MRI) was rarely performed. We performed a multicenter retrospective study to investigate the incidence of ONFH and the need for conversion hip arthroplasty after FNF screw fixation.

View Article and Find Full Text PDF

Purpose: Total hip arthroplasty (THA) after vascularized fibular grafting (VFG) is technically demanding with poorer outcomes compared to primary THA in patients with osteonecrosis of the femoral head (ONFH). The purpose of this study was to compare the outcomes of THA after VFG after removal of the graft with that of primary THA.

Methods: ONFH patients treated by VFG at a single institution were studied retrospectively.

View Article and Find Full Text PDF

Background: The aim of this study was to investigate whether the use of three-dimensional (3-D) computed tomography (CT)-based head-lesser trochanter distance (HLD) could reduce leg length discrepancy (LLD) more than the use of a two-dimensional (2-D) plain film method in primary bipolar hemiarthroplasty. Methods: Propensity score matching (PSM) analysis was used to adjust the confounding factors. A retrospective comparative analysis of 128 patients was performed.

View Article and Find Full Text PDF

Background And Objectives: Epidemiological studies have inconsistently shown an association between dioxin and risk of type 2 diabetes mellitus (T2DM) and cancer. This study aims to examine the effects of blood concentration of dioxin-like polychlorinated biphenyls (DL-PCBs) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/DFs) on T2DM and thyroid cancer.

Methods: We conducted a nested case-control study within the Korean cancer prevention study-II (KCPS-II) consisting of 15 thyroid cancer cases, 30 T2DM cases, and 55 controls.

View Article and Find Full Text PDF

In this study, 16 children's products with the highest detection potential of phthalates were selected, and a phthalate assay and transdermal delivery analysis (NIER, US EPA Wipe [stress condition], US EPA Wipe [physiological condition], and US EPA Hand Wipe) were conducted with these products. The content of 6 controlled phthalates (DBP, BBP, DEHP, DNOP, DINP, and DIDP) was measured and most products contained more phthalates than the regulated guidelines (a total content of 6 phthalates to be ≤0.1%).

View Article and Find Full Text PDF

Background: This study was designed as a cohort study using propensity-score matching to age, gender, and body mass index (BMI) for finite element model (FEM) analysis from pre-collapse CT images of collapsed and non-collapsed hips. Through FEM analysis, a global graphical output around the hip joint can provide simple impression of stress distribution: concentration or dispersion.

Methods: A total of 32 hips with ARCO stage 2 or 3 ONFH who were on follow up for over a one-year period were retrospectively reviewed.

View Article and Find Full Text PDF

Background: Acetabular prosthesis positioning in total hip arthroplasty (THA) is crucial in reducing the risk of dislocation. There has been minimal research on the proper way to put the acetabular components into the safe zone intraoperatively. Assessment of version by intraoperative imaging intensifier is very valuable.

View Article and Find Full Text PDF

Direct metal fabrication (DMF) coatings have the advantage of a more uniform porous structure and superior mechanical properties compared to coatings provided by other methods. We applied pure titanium metal powders to SUS316L stainless steel using laser-aided DMF coating technology with 3D printing. The purpose of this study was to determine the efficacy of this surface modification of stainless steel.

View Article and Find Full Text PDF

Background: Recently, a femoral stem treated with grit-blasting and micro-arc oxidation (MAO) coating has commercialised but medium-term follow-up studies are lacking. The aim of this study was to report the outcome of a grit-blasted and MAO-coated femoral component designed as a straight, double-wedged, tapered stem with a rectangular cross-section with minimum 10 years follow-up.

Methods: Between March 2006 and December 2008, 309 primary total hip arthroplasties using a grit-blasted and MAO-coated femoral component were performed by 3 experienced hip surgeons in 3 hospitals.

View Article and Find Full Text PDF

Background: Titanium surface coating on cobalt-chromium (CoCr) alloy has characteristics desirable for an orthopedic implant as follows: strength, osteointegrative capability, and biocompatibility. Creating such a coated surface takes a challenging process and two dissimilar metals are not easily welded. In our study, we utilized additive manufacturing with a 3D printing called direct metal fabrication (DMF) and compared it to the plasma spraying method (TPS), to coat titanium onto CoCr alloy.

View Article and Find Full Text PDF

Background: The number of young patients with hematological disease requiring total hip arthroplasty (THA) is expected to increase. We aimed to investigate the long-term THA outcomes in patients with osteonecrosis of the femoral head (ONFH) following allogeneic bone marrow transplantation (BMT) for hematological disease.

Methods: All patients who underwent THA for osteonecrosis after BMT from 1997 to 2012 were identified at 2 institutions.

View Article and Find Full Text PDF

Purpose: There has been no prior study to demonstrate the relationship between the occurrence of fragility fractures of the pelvis and its morphology. The aim of this study was to investigate the effect of pelvic morphology on fragility fractures of the pelvis caused by low-energy trauma in elderly female patients.

Materials And Methods: As a normal pelvis group, 643 female patients over 65 years of age who underwent pelvic CT were collected.

View Article and Find Full Text PDF

This study proposes a method for measuring the volumetric change of alveolar bone after dental implant surgery using computed tomography (CT). A total of 40 implants in 20 patients (15 males and 5 females) were selected. The types of implants used were group 1: 24 CMI IS-II Active implants (Neobiotech Co.

View Article and Find Full Text PDF

Background: Using data from the Korean Hip Registry, we aimed to investigate mid-term clinical and radiographic outcomes, including the prevalence of periprosthetic joint infection (PJI), osteolysis, and component loosening or dislocation, and to analyze the incidence of bearing-related complications following modern ceramic-on-ceramic (COC) total hip arthroplasty (THA) using a single cementless hip system.

Methods: Four hundred eighty-two patients (602 hips) who underwent Forte or Delta COC THAs with a single hip system and had a minimum 5-year follow-up were identified. The sample included 243 (50.

View Article and Find Full Text PDF

Background: Three-dimensional (3D) printing with a direct metal fabrication (DMF) technology has been innovatively introduced in the field of surface treatment of prostheses. The purpose of this study was to determine whether such modifications on the surface of cobalt-chromium (CoCr) alloy by titanium powder coating using DMF improves the osseointegration ability of CoCr alloy.

Methods: We compared the and ability of cells to adhere to DMF-coated CoCr alloy with machining.

View Article and Find Full Text PDF

Background: To evaluate how canal morphology affects the technical aspects of total hip arthroplasty, we investigated the effects of femoral cortical index (FCI) on the re-establishment of leg length at the conclusion of surgery.

Methods: We retrospectively reviewed age, gender, body mass index, and radiographs of 516 patients with osteoarthritis or osteonecrosis who underwent unilateral cementless primary total hip arthroplasty between 2008 and 2015. Patients were divided into level of FCI and leg length discrepancy (LLD).

View Article and Find Full Text PDF

Background: Carbon monoxide (CO) is one of the primary components of emissions from light-duty vehicles, and reportedly comprises 77% of all pollutants emitted in terms of concentration. Exposure to CO aggravates cardiovascular disease and causes other health disorders. The study was aimed to assess the negative effects by injecting different amounts of CO concentration directly to human volunteers boarding in the car.

View Article and Find Full Text PDF