Publications by authors named "Young Chan Jeon"

Statement Of Problem: The fit and performance of prostheses fabricated using various computer-aided design and computer-aided manufacturing (CAD-CAM) systems have been evaluated. However, most studies were conducted in vitro, and relatively few have addressed gingival parameters and prosthesis fit under clinical conditions.

Purpose: This clinical study aimed to compare the fit of lithium disilicate crowns produced using 3 CAD-CAM systems and evaluate clinical results up to 6 months after delivery.

View Article and Find Full Text PDF

The aim of this in-vitro research was to evaluate the microtensile bond strength in the newly introduced PEKK tooth post with various surface treatments and resin cements. A fiberglass tooth post was included in order to compare it with PEKK as a possible post material. The microtensile bond strengths of the fiberglass post (FRC Postec Plus) and the PEKK post (Pekkton) were tested using three kinds of self-adhesive resin cements (G-CEM LinkAce, Multilink Speed, and RelyX U200) and one self-etching resin cement (PANAVIA F2.

View Article and Find Full Text PDF

Purpose: This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis.

Materials And Methods: Implant fixtures were placed on the mandibular right second premolar, and the first and second molar in a polyurethane model. Aluwax (A), Pattern Resin (P), and Blu-Mousse (B) were used as the bite registration materials on the healing abutments (H) or temporary abutments (T).

View Article and Find Full Text PDF

The purpose of this study is to evaluate the effect of three-dimensional preformed titanium membrane (3D-PFTM) to enhance mechanical properties and ability of bone regeneration on the peri-implant bone defect. 3D-PFTMs by new mechanically compressive molding technology and manually shaped- (MS-) PFTMs by hand manipulation were applied in artificial peri-implant bone defect model for static compressive load test and cyclic fatigue load test. In 12 implants installed in the mandibular of three beagle dogs, six 3D-PFTMs, and six collagen membranes (CM) randomly were applied to 2.

View Article and Find Full Text PDF

This study was conducted to evaluate the effect of biphasic calcium phosphate (BCP) coated with reduced graphene oxide (rGO) as bone graft materials on bone regeneration. The rGO-coated BCP bone graft material was fabricatied by mixing rGO and BCP at various concentrations. The surface charge of rGO-coated BCP was measured to be -14.

View Article and Find Full Text PDF

This study introduces the effect of the thickness of a bacterial cellulose membrane by comparing the bone regeneration effect on rat skulls when using a collagen membrane and different thicknesses of resorbable bacterial cellulose membranes for guided bone regeneration. Barrier membranes of 0.10 mm, 0.

View Article and Find Full Text PDF

This study was performed to make comparative analysis of the clinical findings between the two different types of the implant-assisted removable partial dentures: removable partial dentures using implant surveyed bridge as an abutment (ISBRPD) and overdenture type of removable partial denture using implant attachment (IARPD). Implant cumulative survival rate, marginal bone resorption, probing depth, peri-implant inflammation, bleeding, plaque, calculus, and complications were evaluated on 24 patients who were treated with implants in conjunction with removable partial denture and have used them for at least 1 year (ISCRPD: = 12; IARPD: = 12). There was no failed implant and all implants were functioning without clinical mobility.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique.

Materials And Methods: Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients.

Materials And Methods: Implant survival rate, marginal bone loss, probing depth, peri-implant inflammation, bleeding, plaque, calculus, complications, and satisfaction were evaluated on sixteen patients who were treated with mandibular overdenture and have used it for at least 1 year (Locator implant attachment: n=8, Locator bar attachment: n=8).

Results: Marginal bone loss, probing depth, plaque index of the Locator bar attachment group were significantly lower than the Locator implant attachment group (P<.

View Article and Find Full Text PDF

Purpose: The aim of this study was to compare the changes in retentive force of stud attachments for implant overdentures by in vitro 2-year-wear simulation.

Materials And Methods: Three commercially available attachment systems were investigated: Kerator blue, O-ring red, and EZ lock. Two implant fixtures were embedded in parallel in each custom base mounting.

View Article and Find Full Text PDF

Background: Recently, non-thermal atmospheric pressure plasma sources have been used for biomedical applications such as sterilization, cancer treatment, blood coagulation, and wound healing. Gold nanoparticles (gNPs) have unique optical properties and are useful for biomedical applications. Although low-temperature plasma has been shown to be effective in killing oral bacteria on agar plates, its bactericidal effect is negligible on the tooth surface.

View Article and Find Full Text PDF

Purpose: This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability.

Materials And Methods: Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge.

View Article and Find Full Text PDF

Purpose: The accuracy of a gypsum model (GM), which was taken using a conventional silicone impression technique, was compared with that of a polyurethane model (PM), which was taken using an iTero™ digital impression system.

Materials And Methods: The maxillary first molar artificial tooth was selected as the reference tooth. The GMs were fabricated through a silicone impression of a reference tooth, and PMs were fabricated by a digital impression (n=9, in each group).

View Article and Find Full Text PDF

Unlabelled: Light-activated tooth bleaching with a high hydrogen peroxide (HP; H2O2) concentration has risks and the actual role of the light source is doubtful. The use of conventional light might result in an increase in the temperature and cause thermal damage to the health of the tooth tissue.

Objective: This study investigated the efficacy of tooth bleaching using non-thermal atmospheric pressure plasma (NAPP) with 15% carbamide peroxide (CP; CH6N2O3) including 5.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the stability of arginine-glycine-aspartic acid (RGD) peptide coatings on implants by measuring the amount of peptide remaining after installation.

Materials And Methods: Fluorescent isothiocyanate (FITC)-fixed RGD peptide was coated onto anodized titanium implants (width 4 mm, length 10 mm) using a physical adsorption method (P) or a chemical grafting method (C). Solid Rigid Polyurethane Foam (SRPF) was classified as either hard bone (H) or soft bone (S) according to its density.

View Article and Find Full Text PDF

Purpose: Autoclaves and UV sterilizers have been commonly used to prevent cross-infections between dental patients and dental instruments or materials contaminated by saliva and blood. To develop a dental sterilizer which can sterilize most materials, such as metals, rubbers, and plastics, the sterilization effect of an atmospheric pressure non-thermal air plasma device was evaluated.

Materials And Methods: After inoculating E.

View Article and Find Full Text PDF

Objective: This study compared the effect of the use of a ready-made plastic stent on the width of peri-implant keratinized mucosa with that of conventional methods and examined the effects of a plastic stent on peri-implant soft tissue.

Materials And Methods: Five young-adult beagle dogs were used. Forty titanium implants were placed in the mandibular alveolar ridge.

View Article and Find Full Text PDF

The purpose of this study was to investigate the healing capacity within an 8-mm rabbit calvarial defect using a polycaprolactone (PCL)/poly(lactic-co-glycolic acid) (PLGA) scaffold blended with tri-calcium phosphate (TCP) that was constructed using solid freeform fabrication (SFF) technology. The PCL/PLGA/TCP scaffold showed a 37 % higher compressive strength and rougher surface than the PCL/PLGA scaffold. In animal experiments, new bone formation was analyzed using microcomputed tomography (micro-CT) and histological and histometric analyses.

View Article and Find Full Text PDF

This study developed a bioabsorbable-guided bone regeneration membrane made of blended polycaprolactone (PCL), poly(lactic-co-glycolic acid) (PLGA), and beta-tricalcium phosphate (β-TCP) using solid freeform fabrication (SFF) technology. The chemical and physical properties of the membrane were evaluated using field emission scanning electron microscopy, energy dispersive spectroscopy, and a tensile test. In vitro cell activity assays revealed that the adhesion, proliferation, and osteogenic differentiation of seeded adipose-derived stem cells (ADSCs) were significantly promoted by the PCL/PLGA/β-TCP membranes compared with PCL/PLGA membranes.

View Article and Find Full Text PDF

Various options have been introduced for the selection of implant overdenture attachments. Attachment wear due to the repeated insertion and removal of dentures has caused problems such as decreased retention and the requirement for suprastructure remanufacturing. In these cases, a Locator bar system was applied using the drill and tapping technique to achieve total retrievability.

View Article and Find Full Text PDF

Purpose: The objective of this study was to investigate the effects of different microthread designs and implant-abutment connection configurations of scalloped implants on stress distribution in bone using three-dimensional finite element analysis.

Materials And Methods: Three different designs of scalloped implants (two different microthread designs and one without microthreads) with two different connection systems and two flat-top implants with similar connection systems were compared in a bone model that mimicked the anterior maxilla. Vertical and oblique (30-degree) loading with 100 N of force was applied to eight models.

View Article and Find Full Text PDF

This study evaluated the microhardness and polymerization shrinkage of flowable resins that are cured using different light sources. Seven flowable resins and two light sources (diode-pumped solid-state (DPSS) laser (LAS) and Optilux 501 (OP)) were chosen for the study. To evaluate the microhardness, a mold (height: 2 mm, inner diameter: 4 mm) was filled with resin and then light cured.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate the effect of titanium surface treatment on Porphyromonas gingivalis bacterial attachment.

Materials And Methods: Titanium disks of 15 mm in diameter and 1 mm in thickness (n=40) were subjected to mechanical grinding, or sandblasting. Magnesium (Mg) ions were implanted onto the titanium surface using a plasma source ion implantation method.

View Article and Find Full Text PDF

The aim of this study was to provide a basis for examining the molecular mechanism for the pharmacological action of dopamine.HCl (DA) and chlorpromazin.HCl (CPZ).

View Article and Find Full Text PDF