Interv Radiol (Higashimatsuyama)
November 2024
Computed tomography-guided puncture is a useful technique for various interventional radiology procedures. Puncture from various locations and angles becomes possible using this technique. Moreover, bone and air do not interfere with the computed tomography image.
View Article and Find Full Text PDFPurpose: To evaluate, experimentally and clinically, the radioprotective effects of a semicircular X-ray shielding device for operators during CT fluoroscopy-guided IR procedures.
Materials And Methods: During experimentation, the reduction rates of scattered radiation rates from CT fluoroscopy were evaluated using a humanoid phantom. Two shielding device positions were tested: "shielding close to the CT gantry" and "shielding close to the operator".
Nihon Hoshasen Gijutsu Gakkai Zasshi
September 2019
In April 2011, the International Radiological Protection Committee recommended that "The equivalent dose of the crystalline lens should not exceed 20 mSv/year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv". Based on this recommendation, it is predicted that the equivalent dose limit of our crystalline lens can be lowered in the near future. Therefore, it is important to grasp the current situation of radiation exposure.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
July 2019
In many facilities, the displayed dose of dose-area product (DAP) is used for the dose management of interventional radiology. In this study, we investigated the measured dose at the patient entrance reference point (interventional reference point) and the displayed dose on each angiography systems. Also, we investigated the calibration method of each DAP.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
September 2017
Purpose: Determination of X-ray fluoroscopy radiation dose and contrast with angiographic system automatically depending on the objects, and to control setting manually, which is difficult for the measurement of characteristics. Therefore, we examined the method to adjust the conditions of fluoroscopy and measured the input-output characteristics.
Method: To adjust and fix the condition of fluoroscopy, the exposure adjustment area at the center of the irradiation field was moved to the left side and attached the copper plates to regulate the exposure dose.
Nihon Hoshasen Gijutsu Gakkai Zasshi
January 2016
The role of the X-ray fluoroscopic image during interventional radiology (IVR) is not only the real-time dynamic image for the catheter operation but also to confirm the vascular anatomy using stored image, so that the importance increases more. For the purpose of measuring the time sequence characteristics of X-ray fluoroscopic image, we sampled the digital value of the same coordinate from each X-ray fluoroscopic image and calculated the frequency properties of the noise for the time sequence order as NPStime by performing Fourier transform on the digital value. The parameters, except k-factor which is the time sequence filter, did not influence NPStime.
View Article and Find Full Text PDF