This study developed internal dose coefficients for radioiodine, tailored to the Korean population, by incorporating the Korean biokinetic model along with the Korean S values. The observed differences in dose coefficients for Koreans compared to the International Commission on Radiological Protection (ICRP) reference values noticeably varied depending on physical half-lives of iodine isotopes. For longer-lived isotopes such as I-125 and I-129, significant differences in thyroid dose coefficients were observed, with ratios (Korean/ICRP) from 0.
View Article and Find Full Text PDFBackground: Previous study proposed a method to measure linear energy transfer (LET) at specific points using the quenching magnitude of thin film solar cells. This study was conducted to propose a more advanced method for measuring the LET distribution.
Purpose: This study focuses on evaluating the feasibility of estimating the proton LET distribution in proton therapy.
Purpose: Regional nodal irradiation (RNI) to the axilla and supraclavicular area presents distinct toxicities, such as lymphedema and shoulder stiffness, compared with whole-breast irradiation. There is insufficient evidence on the safety of dose-escalation in hypofractionated RNI. We aimed to evaluate and compare toxicity rates in patients with breast cancer who received hypofractionated RNI with and without dose-escalation.
View Article and Find Full Text PDFPurpose: The quality of on-board imaging systems, including cone-beam computed tomography (CBCT), plays a vital role in image-guided radiation therapy (IGRT) and adaptive radiotherapy. Recently, there has been an upgrade of the CBCT systems fused in the O-ring linear accelerators called HyperSight, featuring a high imaging performance. As the characterization of a new imaging system is essential, we evaluated the image quality of the HyperSight system by comparing it with Halcyon 3.
View Article and Find Full Text PDFThe use of iodine S values derived using the International Commission Radiological Protection (ICRP) phantoms may introduce significant bias in internal dosimetry for Koreans due to anatomical variability. In the current study, we produced an extensive dataset of Korean S values for selected five iodine radioisotopes (I-125, I-129, I-131, I-133, and I-134) for use in radiation protection. To calculate S values, we implemented Monte Carlo simulations using the Mesh-type Reference Korean Phantoms (MRKPs), developed in a high-quality/fidelity mesh format.
View Article and Find Full Text PDFThe Korea Institute of Radiological and Medical Sciences has started a radiation epidemiological study, titled "Korean Radiation Worker Study," to evaluate the health effects of occupational exposure to radiation. As a part of this study, we investigated the methodologies and results of reconstructing organ-specific absorbed doses based on personal dose equivalent, (10), reported from 1984 to 2019 for 20,605 Korean radiation workers. For the organ dose reconstruction, representative exposure scenarios (i.
View Article and Find Full Text PDFCraniospinal irradiation using helical tomotherapy (HT-CSI) has advantages in aspects of homogeneous dose distribution. Physicians, however, still have concerns of pulmonary toxicity due to HT-CSI's relatively large, low-dose irradiated volume from continuous and 360° rotation delivery. In this study, we investigated the pulmonary toxicity of HT-CSI.
View Article and Find Full Text PDFVarious deformable image registration (DIR) methods have been used to evaluate organ deformations in 4-dimensional computed tomography (4D CT) images scanned during the respiratory motions of a patient. This study assesses the performance of 10 DIR algorithms using 4D CT images of 5 patients with fiducial markers (FMs) implanted during the postoperative radiosurgery of multiple lung metastases. To evaluate DIR algorithms, 4D CT images of 5 patients were used, and ground-truths of FMs and tumors were generated by physicians based on their medical expertise.
View Article and Find Full Text PDFWe investigated the practical aspects of the application of craniospinal irradiation using helical tomotherapy (HT-CSI) by evaluating interfractional setup errors and intrafractional movement during each treatment in 83 patients undergoing HT-CSI between January 2014 and December 2018. Interfractional setup errors in each axis (mediolateral; ML, craniocaudal; CC, and anteroposterior; AP) were assessed as differences between pre-treatment megavoltage computed tomography (MVCT) images scanned (zygomatic arch to the C4 spine) and planning CT images. Intrafractional movements were evaluated as the difference between pre-treatment and post-treatment MVCT (T12-L4 spine) images at each fraction.
View Article and Find Full Text PDFThe International Commission on Radiological Protection (ICRP) recently adopted a detailed biokinetic model for systemic iodine with reference transfer coefficients based on typical worldwide dietary intakes of stable iodine. The regional data provided demonstrate that the ICRP reference thyroidal biokinetics may differ substantially across regions with atypically low or high dietary intakes of stable iodine. Importantly, the design of the ICRP model facilitates modifications of reference thyroidal kinetics based on regional dietary iodine intake.
View Article and Find Full Text PDFBackground: Despite detailed instruction for full bladder, patients are unable to maintain consistent bladder filling during a 5-week pelvic radiation therapy (RT) course. We investigated the best bladder volume estimation procedure for verifying consistent bladder volume.
Methods: We reviewed 462 patients who underwent pelvic RT.
Bioassay functions, which are provided by the International Commission on Radiological Protection, are used to estimate the intake activity of radionuclides; however, they include considerable uncertainties in terms of the internal dosimetry for a particular individual. During a practical internal dose assessment, the uncertainty in the bioassay function is generally not introduced because of the difficulty in quantification. Therefore, to clarify the existence of uncertainty in the bioassay function and provide dosimetrists with an insight into this uncertainty, this study attempted to quantify the uncertainty in the thyroid retention function used for radioiodine exposure.
View Article and Find Full Text PDFPurpose: To evaluate and compare the feasibilities of magnetic resonance (MR) image-based planning using synthetic computed tomography (sCT) versus CT (pCT)-based planning in helical tomotherapy for prostate cancer.
Materials And Methods: A retrospective evaluation was performed in 16 patients with prostate cancer who had been treated with helical tomotherapy. MR images were acquired using a dedicated therapy sequence; sCT images were generated using magnetic resonance for calculating attenuation (MRCAT).
Recent studies have highlighted the implications of genetic variations in the relative biological effectiveness (RBE) of proton beam irradiation over conventional X-ray irradiation. Proton beam radiotherapy is a reasonable radiotherapy option for hepatocellular carcinoma (HCC), but the impact of genetic difference on the HCC RBE remains unknown. Here, we determined proton RBE in human HCC cells by exposing them to various doses of either 6-MV X-rays or 230-MeV proton beams.
View Article and Find Full Text PDFIodine thyroid blocking (ITB) suppresses the uptake of iodine to the thyroid and reduces internal doses after radioiodine intake; however, its disturbance of thyroid biokinetics causes considerable uncertainty in the use of dosimetric data intended for assessment of unblocked normal thyroid. To more accurately assess internal dose after ITB, practical dosimetry methods were proposed that consider the ITB effect in a dosimetric manner. A method using the ratio of urine excretion to thyroid retention activity was proposed to retrospectively determine individual-specific ITB levels; bioassay functions and dose coefficients corresponding to ITB levels were calculated separately using the latest biokinetic model and fundamental data.
View Article and Find Full Text PDFThe purpose of this study was to analyze the effectiveness of electron beam therapy (EBT) with patient-tailored bolus (PTB) using three-dimensional printing technology to reduce heart and lung doses during post-mastectomy radiotherapy (PMRT). For 28 patients with left breast cancer, we designed customized virtual bolus for PMRT to compensate for surface irregularities on computed tomography images and developed optimized plans for EBT. As comparison between the PTB and tangential plans, the PTB plan reduced unnecessary exposure to heart and ipsilateral lung with better target coverage compared with the tangential technique.
View Article and Find Full Text PDFPurpose: This first Korean prospective study is to evaluate the feasibility of prone breast radiotherapy after breast conserving surgery for left breast cancer patients who have relatively small breast size and we present dosimetric comparison between prone and supine positions.
Materials And Methods: Fifty patients underwent two computed tomography (CT) simulations in supine and prone positions. Whole breast, ipsilateral lung, heart, and left-anterior-descending coronary artery were contoured on each simulation CT images.
J Appl Clin Med Phys
November 2018
Purpose: The delivery quality assurance (DQA) of intensity-modulated radiotherapy (IMRT) plans is a prerequisite for ensuring patient treatments. This work investigated the clinical usefulness of a new DQA system, Dosimetry Check™(DC), on TomoTherapy -based helical IMRT plans.
Methods: The DQA was performed for 15 different TomoTherapy -based clinical treatment plans.
Purpose/objective: This study aimed to assess protocol compliance based on an individual case review (ICR) of the Korean Radiation Oncology Group-0806 trial.
Methods And Materials: For the ICR, 747 participants were divided into eight subgroups based on internal mammary node irradiation (IMNI), tumor laterality, and surgery type. Next, 15% of patients were randomly selected within each subgroup, and corresponding hospitals were subsequently requested to upload information related to radiation therapy (RT) planning.
Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS.
Materials And Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV.
Purpose: The Korean Society of Radiation Oncologists (KOSRO) conducted the Patterns of Care Study (PCS) of radiotherapy (RT) for spine metastases in 2009. The current study was conducted to investigate current practice patterns and compare them with the results of the PCS.
Materials And Methods: The survey questionnaire was composed of 10 questions regarding general information and seven questions for each of two clinical scenarios.
Herein, we evaluated the feasibility of placing patients in a tilted head position as part of routine clinical practice for fractionated stereotactic radiotherapy (FSRT) of intracranial tumors using helical tomotherapy (HT), by assessing its dosimetric benefit and setup accuracy. We reviewed treatment plans of four cases that were to receive FSRT for brain lesions in normal and head-tilted positions. These patients underwent two computed tomography (CT) scans: first in the normal supine position and then in the supine position with the head tilted at a 458 angle.
View Article and Find Full Text PDFPurpose: The maintenance of full bladder is important to reduce radiation-induced toxicities and maintain the therapeutic consistency in locally advanced rectal cancer patients who underwent radiotherapy (RT). So, the aim of this study was to evaluate the effectiveness of protocol-based full bladder maintenance by assessing bladder volume variation using an ultrasound bladder scanner to maintain bladder volume.
Materials And Methods: From March 2011 to May 2011, twenty consecutive rectal cancer patients receiving external beam RT participated in this prospective study.
Purpose: A new automatic quality assurance (AutoRCQA) system using a three-dimensional scanner (3DS) with system automation was developed to improve the accuracy and efficiency of the quality assurance (QA) procedure for proton range compensators (RCs). The system performance was evaluated for clinical implementation.
Methods: The AutoRCQA system consists of a three-dimensional measurement system (3DMS) based on 3DS and in-house developed verification software (3DVS).