Purpose: We described a technique to perform anterior synechiolysis with a healon needle and Viscoat® ophthalmic viscosurgical devices (OVDs) through anterior lamellar dissection in penetrating keratoplasty.
Methods: OVDs were gently injected between iridocorneal adhesions with a healon needle to make a blunt dissection after anterior lamellar corneal dissection. Anterior synechiolysis at 360 degrees was completed with a healon needle and OVDs.
Purpose: The aim of this study was to evaluate the treatment effect of diquafosol 3% with preservative-free sodium hyaluronate 0.1% eye drops in dry eye syndrome.
Methods: In total, 150 patients with dry eye syndrome were divided randomly into 3 groups.