Nihon Hoshasen Gijutsu Gakkai Zasshi
January 2022
Purpose: Accurate positioning is essential for radiography, and it is especially important to maintain image reproducibility in follow-up observations. The decision on re-taking radiographs is entrusting to the individual radiological technologist. The evaluation is a visual and qualitative evaluation and there are individual variations in the acceptance criteria.
View Article and Find Full Text PDFReduced graphene oxide and molybdenum disulfide (rGO:MoS) are the most representative two-dimensional materials, which are promising for a humidity sensor owing to its high surface area, a large number of active sites, and excellent mechanical flexibility. Herein, we introduced a highly sensitive and stable rGO:MoS-based humidity sensor integrated with a low-power in-plane microheater and a temperature sensor, directly insertable to transformer insulating oil, and analyzed by a newly developed customized sensor interface electronics to monitor the sensor's output variations in terms of relative humidity (RH) concentration. rGO:MoS sensing materials were synthesized by simple ultrasonication without using any additives or additional heating and selectively deposited on titanium/platinum (Ti/Pt) interdigitated electrodes on a SiO substrate using the drop-casting method.
View Article and Find Full Text PDFObjective: Despite the high risk of missing lesions in mammography, the missed lesion rate is yet to be clinically established. Further, no breast phantoms with adjustable breast density currently exist. We developed a novel, adjustable-density breast phantom with a composition identical to that of actual breasts, and determined the quantitative relationship between breast density and the missed lesion rate in mammography.
View Article and Find Full Text PDFRadiol Phys Technol
December 2020
Bedside radiography has increasingly attracted attention because it allows for immediate image diagnosis after X-ray imaging. Currently, wireless flat-panel detectors (FPDs) are used for digital radiography. However, adjustment of the X-ray tube and FPD alignment are extremely difficult tasks.
View Article and Find Full Text PDFPurpose: To evaluate the usefulness of deep learning-assisted diagnosis for identifying hyperdense middle cerebral artery sign (HMCAS) on non-contrast computed tomography in comparison with the diagnostic performance of neuroradiologists.
Materials And Methods: We obtained 46 HMCAS-positive and 52 HMCAS-negative test samples extracted using 50-pixel-diameter circular regions of interest. Five neuroradiologists undertook an initial diagnostic performance test by describing the HMCAS-positive prediction rate in each sample.
Purpose: The aim of this study was to develop an interactive deep learning-assisted identification of the hyperdense middle cerebral artery (MCA) sign (HMCAS) on non-contrast computed tomography (CT) among patients with acute ischemic stroke.
Materials And Methods: 35 HMCAS-positive and 39 HMCAS-negative samples extracted by 50-pixel-diameter circular regions of interest were obtained as training and validation datasets according to the consensus decisions of two experienced neuroradiologists. Data augmentation was performed to increase the number of training samples.
Nihon Hoshasen Gijutsu Gakkai Zasshi
March 2019
Countermeasures against respiratory movement are important for tumors of thorax and abdomen in stereotactic body radiation therapy. In the present paper, a web-camera-based-respiratory monitoring method without contact with patient's body was proposed for respiratory study. Thoracic and abdominal motion images were taken by a web camera, and were analyzed using simple image-processing techniques for obtaining respiratory waveforms.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
March 2019
In computed tomography coronary angiography (CTCA), calcification and stent make it difficult to evaluate intravascular lumen. This is a cause of low positive-predictive value of coronary stenosis. Therefore, it is expected to develop a computer-aided diagnosis (CAD) system that can automatically detect stenosis in coronary arteries.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
January 2018
Purpose: CT perfusion (CTP) is a powerful tool for the assessment of cerebrovascular disease. However, CTP maps are significantly different depending on CTP software and algorithm, even when using identical image data. We developed a phase-ratio image map (PI map), which was a novel perfusion map, without using CTP software.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
November 2015
CT perfusion (CTP) is obtained cerebrovascular circulation image for assessment of stroke patients; however, at the expense of increased radiation dose by dynamic scan. Iterative reconstruction (IR) method is possible to decrease image noise, it has the potential to reduce radiation dose. The purpose of this study is to assess the visual effect of IR method by using a digital perfusion phantom.
View Article and Find Full Text PDFThe volume of the temporal horn of the lateral ventricle (THLV) on brain computed tomography (CT) images is important for neurologic diagnosis. Our purpose in this study was to develop a z-score-based semi-quantitative analysis for estimation of the THLV volume by using voxel-based morphometry. The THLV volume was estimated by use of a z-score mapping method that consisted of four main steps: anatomic standardization, construction of a normal reference database, calculation of the z score, and calculation of the mean z score in a volume of interest (VOI).
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
March 2014
In this paper, we propose a detection method for blurred regions in radiographs. The method involves edge detection using a Sobel filter, manually determining the region of interest (ROI), feature calculation, and classification using a support vector machine. We applied our method to 14 phantom images (7 normal images, 7 blurred images) and 14 clinical images (12 normal images, 2 blurred images).
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
March 2014
Objective evaluation, e.g., using the modulation transfer function (MTF) or the noise power spectrum (NPS) of an X-ray imaging system may not correctly correspond to the subject's evaluation, e.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2015
The purpose of this study was to evaluate the performance of a conventional discrete wavelet transform (DWT) method and a modified undecimated discrete wavelet transform (M-UDWT) method applied to mammographic image denoising. Mutual information, mean square error, and signal to noise ratio were used as image quality measures of images processed by the two methods. We examined the performance of the two methods with visual perceptual evaluation.
View Article and Find Full Text PDFThe hyperdense middle cerebral artery (MCA) dot sign representing a thromboembolus is one of the important computed tomography (CT) findings for acute stroke on unenhanced CT images. Our purpose in this study was to develop an automated method for detection of the MCA dot sign of acute stroke on unenhanced CT images. The algorithm of the method which we developed consisted of 5 major steps: extraction of the sylvian fissure region, initial identification of MCA dots based on the morphologic top-hat transformation, feature extraction of candidates, elimination of false positives (FPs) by use of a rule-based scheme, and classification of candidates using a support vector machine (SVM) classifier with four features.
View Article and Find Full Text PDFIn this work, the authors present an effective denoising method to attempt reducing the noise in mammographic images. The method is based on using hierarchical correlation of the coefficients of discrete stationary wavelet transforms. The features of the proposed technique include iterative use of undecimated multi-directional wavelet transforms at adjacent scales.
View Article and Find Full Text PDFMammography has become widespread as a standard method for breast cancer screening. For women undergoing mammography, compression of the breast and special positioning are requested, and they cause the physical burden and pain. However, the reality of the physical burden and subjective pain associated with mammography are not fully understood.
View Article and Find Full Text PDFIn Japan, radiologists and radiologic technologists are endeavoring to improve the quality of lung CT screening. In particular, preliminary screening by radiologic technologists is expected to decrease radiologists' burden and improve the accuracy of CT screening. We considered that an application of computer-aided detection (CAD) would also be as useful in preliminary screening as in the radiologist's regular reading.
View Article and Find Full Text PDFOur purpose in this study was to develop a computer-aided detection scheme for identification of hypoattenuation of acute stroke on unenhanced CT images to select patients for thrombolysis of acute stroke. This method is based on a z-score mapping method. The algorithm of the developed method consisted of five main steps: anatomic standardization, calculation of the z-score with a normal reference database, extraction of candidate voxels for hypoattenuation, feature extraction, and classification.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
November 2011
This study focused on measuring examinees' muscle activities during mammography positioning using surface electromyography. Muscle activities were measured in three women (40-50s) in two-view mammography (MLO: mediolateral oblique, CC: craniocaudal). The muscles measured were the sternocleidomastoid, biceps, trapezius, and gastrocnemius, selected based on the visual analogue scale reported by Sharp et al.
View Article and Find Full Text PDFPurpose: The objective was to develop and investigate an automated scoring scheme of the American College of Radiology (ACR) mammographic accreditation phantom (RMI 156, Middleton, WI) images.
Methods: The developed method consisted of background subtraction, determination of region of interest, classification of fiber and mass objects by Mahalanobis distance, detection of specks by template matching, and rule-based scoring. Fifty-one phantom images were collected from 51 facilities for this study (one facility provided one image).
Nihon Hoshasen Gijutsu Gakkai Zasshi
December 2010
Objective: The purpose of this study was to evaluate the usefulness of z-score mapping method on neuroradiologists' performance in quantification of the extent of hypoattenuation regions of hyperacute stroke on unenhanced computed tomographic (CT) images by using the Alberta Stroke Programme Early CT Score system.
Methods: Twenty-one patients with infarction (<3 hours) were retrospectively selected. Five neuroradiologists interpreted CT images first without and then with z-score maps by using the Alberta Stroke Programme Early CT Score system.
Nihon Hoshasen Gijutsu Gakkai Zasshi
December 2009
Joint photographic experts group(JPEG)and JPEG2000 are widely used as image compression algorithms in medical image database systems. Compressed images have been mainly evaluated by visual assessment on acceptable compression levels in clinical studies. However, to the best of our knowledge, little work has been done to clarify image properties based on physical analysis.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
September 2009
The present study proposes a method for improving an existing technique used for extracting the centerlines of coronary arteries with calcifications on CTA. Through the use of the improved centerline extraction method, CPR images could be depicted accurately. In the proposed method, two dynamic range compression algorithms using two ITC for blood vessel regions and calcification regions were employed.
View Article and Find Full Text PDF