Guang Pu Xue Yu Guang Pu Fen Xi
March 2015
In order to miniaturize an infrared spectrometer, we analyze the current optical design of miniature spectrometers and propose a method for designing a miniature infrared gratings spectrometer based on planar waveguide. Common miniature spectrometer uses miniature optical elements to reduce the size of system, which also shrinks the effective aperture. So the performance of spectrometer has dropped.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
August 2013
Retrieving atmospheric CO2 concentration from space-based infrared measurements is an ill-posed problem, and the uncertainty of ground properties is an important impacting factor. For the requirement of high precision retrieval of atmospheric CO2, the effects of surface reflectance must be corrected. Thus a surface reflectance correction method is proposed.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
May 2013
Atmospheric carbon dioxide is a key greenhouse gas. Global monitoring of carbon dioxide would be helpful to improving the understanding of climate change. Ground-based observations usually have higher resolution and signal-to-noise ratio and more known parameters than satellite-based observations, which make it easier to achieve a better retrieval precision Ground-based retrieval method could be extended to satellite scenarios, and it could also provide validation for satellite data.
View Article and Find Full Text PDFZhongguo Yi Xue Ke Xue Yuan Xue Bao
October 2011
Objective: To evaluate the role of intracoronary electrocardiogram (IcECG) in examining early myocardial injury during percutaneous coronary intervention (PCI).
Methods: Eight-six patients who had undergone elective PCI for their coronary heart disease were enrolled in the study. The IcECG both at baseline and after procedure were recorded with an incoronary guidewire and the serum levels of cardiac troponin T (cTnT) and creatine kinase-myoglobin were measured at baseline and 8 and 24 hours after intervention.
Guang Pu Xue Yu Guang Pu Fen Xi
October 2011
On the mobile platform, the remote sensing system for pollutant gases can not effectively obtain background spectra. It is the key step to remove background information and extract target spectral characteristics utilizing specific algorithm. The present paper addressed an algorithm based on principal component iterative fitting and brightness temperature spectrum.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
August 2010
Guang Pu Xue Yu Guang Pu Fen Xi
June 2010
Spatial heterodyne spectroscopy (SHS) is a novel method for hyperspectral analysis, but the calibration methods have not been thoroughly studied. The present paper gives some basic theories of SHS, and investigates the laboratory calibration methods, including spectral calibration and radiometric calibration. According to emission lines and the relation between detector size and system bandwidth, we designed the spectral calibration plan for SHS, which uses tunable laser and halogen lamp.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
March 2009
Spatial heterodyne spectroscopy (SHS) is a new spectroscopic technique which can achieve high spectral resolution. The basic concepts of spatial heterodyne spectrometer was described. A method of data processing for interferogram of spatial heterodyne spectrometer was presented based on its characteristics.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
November 2008
Being able to identify pollutant gases quickly and accurately is a basic request of spectroscopic technique for envirment monitoring for spectral classifier. Piecewise linear classifier is simple needs less computational time and approachs nonlinear boundary beautifully. Combining piecewise linear classifier and linear support vector machine which is based on the principle of maximizing margin, an optimizing algorithm for single side piecewise linear classifier was devised.
View Article and Find Full Text PDF