Publications by authors named "Yong-Heum Lee"

Background/aim: Pulsed electromagnetic field (PEMF) stimulation enhances the efficacy of several anticancer drugs. Doxorubicin is an anticancer drug used to treat various types of cancer, including breast cancer. However, the effect of PEMF stimulation on the efficacy of doxorubicin and the underlying mechanisms remain unclear.

View Article and Find Full Text PDF

Background/aim: Caffeic acid phenethyl ester (CAPE) exerts anticancer effects against several cancer types, including breast cancer. Pulsed electromagnetic field (PEMF) improves the efficiency of some chemotherapeutic drugs. In this study, we examined the effects of PEMF stimulation on the anticancer activity of CAPE in MCF-7 breast cancer cells and the underlying signal transduction pathways.

View Article and Find Full Text PDF

This study aimed to evaluate the effectiveness of using low-level, low-frequency pulsed electromagnetic field (LLLF_PEMF) stimulation to improve atopic dermatitis induced by 2,4-dinitrochlorobenzene (DNCB). Twenty 6-week-old hairless mice were randomly divided into Normal (n = 5), PEMF 15 Hz (n = 5), PEMF 75 Hz (n = 5), and Sham (n = 5) groups. Following the onset of atopic dermatitis symptoms, PEMF groups (15 and 75 Hz) were stimulated with LLLF_PEMF (15 mT) for 8 h per day for 1 week.

View Article and Find Full Text PDF

This study aimed to evaluate the effect of Pulsed Electromagnetic Fields (PEMF) in improving blood flow reduction and tissue necrosis of ischemic animal induced by skin flap. In each experiment, twenty rats (280-320 g) were randomly divided into control group (n = 10) and PEMF (n = 10) group. All of the rats were performed skin flap in back.

View Article and Find Full Text PDF

The aim of this study was to compare the influences of manual acupuncture, laser acupuncture, and electromagnetic field stimulation on the autonomic nervous system. We monitored the heart rate variability before and after stimulation to check the influence on the autonomic nervous system. The heart rate variabilities at low frequency (LF; 0.

View Article and Find Full Text PDF

Cupping is one of the various treatment methods used in traditional oriental medicine. Cupping is also used as a diagnostic method and it may cause skin hyperpigmentation. Quantitative measurements and analysis of changes in skin color due to cupping are critical.

View Article and Find Full Text PDF

The aim of this study was to investigate a new method of manual acupuncture that used a magnetic field to stimulate only one acupoint vertically. We developed an eight-channel electromagnetic acupuncture (EMA) system that uses a solenoid-type electrode to insert the manual acupuncture needle into a hole in an electrode. We used a manual acupuncture needle for magnetic induction in order to penetrate vertically and deeply into tissues.

View Article and Find Full Text PDF

Magnetic fields are widely considered as a method of treatment to increase the therapeutic effect when applied to acupoints. Hence, this study proposes a new method which creates significant stimulation of acupoints by using weak magnetic fields. We conducted this experiment in order to confirm the effect on the activation level of the autonomic nervous system by measuring pupil sizes in cases of stimulation by using manual acupuncture and electromagnetic acupuncture (EMA) at BL15.

View Article and Find Full Text PDF

The purpose of this study was to suggest a new method of estimating acupoint compositions by using a multi-frequency bioelectrical impedance analysis (MF-BIA) method at 5 kHz, 50 kHz and 200 kHz within 2 cm of acupoints divided into local segments. To verify the system developed, we confirmed the stable occurrence of a constant current at every frequency, regardless of the impedance connected to the electrodes. Moreover, we found left and right distal bicep brachii aponeurosis to be identical by using ultrasound imaging, and we analyzed the repeatability of the findings by making 10 consecutive sets of measurements (p > 0.

View Article and Find Full Text PDF

The aim of this study was to develop a new method of measuring the meridian energy potential (MEP) at an acupoint with bioelectrical impedance in order to establish an objective meridian diagnosis. To confirm the reflection of the changes in body composition at acupoints, the changes in the MEP on the bladder meridian before, during and after cupping were observed. Additionally, to evaluate the usefulness of diagnosis, the MEP on the stomach meridian before and after a meal was measured.

View Article and Find Full Text PDF

The aim of this study was to find the non-invasive optimal alternative method for Manual Acupuncture. Existing researches had reported that Transcutaneous Electrical Acupoint Stimulation (TEAS) was an effective treatment method instead of manual acupuncture. In place of the TEAS, we suggested the Pulsed Electromagnetic Fields (PEMFs).

View Article and Find Full Text PDF

Specific electrical characteristicsof acupointswere investigated on the urinary bladder (BL) meridian in 14 rats. BL acupointsand non-acupoints on the back were selected and their electrical voltages were measured by using aSPACsystem.The mean voltages of each point or each line were statistically analyzed by using the ANOVA test.

View Article and Find Full Text PDF

Acupuncture in Oriental medicine has been widely used as a core therapeutic method due to its minimal side-effects and therapeutic efficacy. However, the electrical response to acupuncture stimulation (ERAS) has not been clearly studied under acupuncture conditions that might affect the efficacy of acupuncture therapy. In this study, the ERAS was objectively investigated by measuring meridian electric potentials (MEPs) when the electrical grounding conditions of the operator and subject were varied, and when the insulation conditions of acupuncture needle were varied.

View Article and Find Full Text PDF

The conventional acupuncture-point stimulus pattern uses direct current (DC) to discriminate acupuncture point and meridian lines, which are fundamental to diagnosis and treatment in Oriental medicine. However, DC is insufficiently reliable in discriminating these acupuncture points and lines. To overcome these problems, the authors extracted optimal parameters (e.

View Article and Find Full Text PDF

Functional gastrointestinal disorders (FGIDs) affect millions of people without regard for age, race or sex, but little information related to FGIDs and few methods are available for diagnosing FGIDs. Therefore, the aims of this study were to investigate any alterations to the gastrointestinal tracts induced by FGIDs and to develop and test an ultrasonic diagnostic system capable of detecting the alteration in the gastrointestinal tract. Palpation/percussion examinations were performed on 40 participants with or without FGIDs to identify any mechanical alterations to the gastrointestinal tract induced by FGIDs.

View Article and Find Full Text PDF

The purpose of this study was to investigate the differences in bio-potential in the stomach meridians of 20 normal healthy control subjects (NHC) and 20 patients with gastric disease (PGD). We measured changes in potential between ST-39 and ST-37 on the stomach meridian in response to invasive insertion of a needle at ST-36. The response patterns of NHC were regular in both the left and right meridians, whereas the response patterns of PGD were irregular.

View Article and Find Full Text PDF

Therapy using the acupuncture meridian system is an important part of traditional Chinese medicine. The purpose of this study was to investigate the electrical conduction properties of the meridians. The current conduction and potential profiles were compared after switching the current direction in the Hegu (LI-4) and Quchi (LI- 11) meridians and over a non-acupuncture point 1 cm from Quchi (LI-11) in 20 healthy subjects.

View Article and Find Full Text PDF

The conventional acupuncture-point stimulus pattern uses direct current (DC) to discriminate acupuncture point and meridian lines, which are fundamental to diagnosis and treatment in Oriental medicine. However, DC is insufficiently reliable in discriminating these acupuncture points and lines. To overcome these problems, the authors extracted optimal parameters (e.

View Article and Find Full Text PDF

Heart-rate variability (HRV) was compared in 40 subjects receiving external Qi-therapy (QT) or placebo control therapy, in a randomized placebo controlled design experiment. There were significant time, and group x time interactions in heart rate (HR), low frequency (LF), high frequency (HF), and LF/HF. These suggest that QT reduced the HR and increased HRV as indicated by a reduced LF/HF power ratio of HRV.

View Article and Find Full Text PDF

Acupuncture therapy is based on the principle of restoring equilibrium of the body's energy state by regulating the flow of Qi in the corresponding meridians and acupoints. The purpose of this study was to determine whether bio-energy transfer occurs during acupuncture of the meridians. We treated 20 normal healthy subjects with acupuncture and measured changes in the direct current (DC) potential between the stomach meridian points ST-39 and ST-37 in response to invasive insertion of a needle at ST-36.

View Article and Find Full Text PDF

A Single-Power Alternating Current (SPAC) instrument was used to measure the low-impedance acupoints around Ho-Ku (LI-4), Yang-Hsi (LI-5), Yang-Ch'ih (TB-4), Yang-Ku (SI-5), T'ai-Yuan (Lu-9), Ta-Lung (EH-7) and Shen-Men (He-7). A four-electrode instrument was used to measure the subcutaneous impedance at these low-impedance acupoints and adjacent control points on 12 healthy people. The mean subcutaneous impedance at the acupoints was 49.

View Article and Find Full Text PDF

The precise selection and the identification of acupuncture points are essential for the diagnosis and treatment of patients in Oriental medicine. In this study, we have developed a meridian identification system using Single-Power Alternating Current (SPAC), which discriminates between true acupoints and non-acupoints. The SPAC system is not affected by skin resistance or pressure and is more accurate than the existing meridian location system, which uses direct current (DC) excitation current.

View Article and Find Full Text PDF