Introduction: Animal bones have been used as a model to mimic human bones for investigation of fracture patterns and fixation techniques. This study aims to investigate the effects of torsional forces of varying speeds on the spiral fracture in human metacarpal using a chicken humerus model.
Materials And Methods: Thirty fresh-frozen chicken humerus bones were dissected and equally divided into three groups.
This study aimed to compare the torsional resistance of three fixation techniques for spiral metacarpal fractures: screw-only fixation, screw plus neutralization plate fixation, and a locking plate construct. A spiral fracture was created on 18 cadaveric metacarpal bones by applying an axial and torsional loading force using an Instron 3343 mechanical tester. The failure strength was defined as the native torque strength.
View Article and Find Full Text PDFMulti-strand repair of flexor tendons are important for increased strength but this may cause ischemia during the intrinsic healing process. In this study, we aim to compare the strength of the 4-strand modified Asymmetric repair using 2-0 Tenoflex suture with the original description of the Asymmetric repair using a 6-strand 4-0 Supramid suture under cyclic loading in a porcine tendon model. We hypothesise that the number of core sutures through the repair site can be reduced with advanced suture material.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
September 2023
Understanding the stresses on the scapholunate interosseous ligament (SLIL) and its interaction with synovial fluid pressure could be vital to improve wrist treatment for various wrist conditions such as arthritis, sprains and tendonitis. This study investigated the interaction between the intra-articular pressure, specifically the synovial fluid pressure change and the SLIL stresses in a computational model during wrist radioulnar deviation (RUD). Magnetic resonance imaging (MRI) scans were used to acquire the anatomical model of the carpal bones and ligament, while the kinematics of scaphoid and lunate were obtained through dynamic computerized tomography (CT) scans.
View Article and Find Full Text PDFJ Hand Surg Asian Pac Vol
June 2022
Massachusetts General Hospital (MGH) repair is one of the widely used 4-strand flexor tendon repair techniques. However, it uses two single strand sutures that are each passed twice across the repair site. This is time consuming and may cause imbalance of the load across the repair.
View Article and Find Full Text PDFEarly active motion protocols have shown better functional outcomes in zone II flexor tendon lacerations. Different techniques of tendon repair have different effects on gliding resistance, which can impact tendon excursion and adhesion formation. For successful initiation of early active mobilisation, the repair technique should have high breaking strength and low gliding resistance.
View Article and Find Full Text PDFJ Hand Surg Asian Pac Vol
December 2021
: The asymmetric technique for flexor tendon repairs has various advantages but further improvement is possible by using a suitable suture material. In this study, we compare the biomechanical performance of asymmetric repairs using 3 suture materials: Supramid Extra II 4-0, Tendo-Loop 4-0, and FiberLoop 4-0. : We divided 30 porcine flexor tendons into 3 arms.
View Article and Find Full Text PDFIntroduction: Medial migration of the femoral neck element (FNE) superomedially against gravity with respect to the intramedullary component of the cephalomedullary nail is a complication increasingly recognized to cause femoral head cut-out in intramedullary nailing of pertrochanteric hip fractures. Although cut-outs are common to both intra- and extramedullary fixation, especially in unstable pertrochanteric hip fractures, FNE medial migration in sliding hip screws continues to remain sparse despite increased awareness of the phenomenon. This study aims to investigate whether intramedullary nailing is biomechanically predisposed to FNE medial migration compared to extramedullary fixation with sliding hip screws to account for the discrepancy in reported FNE medial migration rates.
View Article and Find Full Text PDFThe introduction of femtosecond laser-assisted cataract surgery is an alternative approach to conventional cataract surgery. Our study aimed to determine the effectiveness of femtosecond laser-assisted capsulotomy in the presence of different ophthalmic viscoelastic devices (OVDs) in the anterior chamber. Fresh porcine eyes (n = 96) underwent LDV Z8-assisted anterior capsulotomy, either in the presence of an OVD (Viscoat, Provisc, Healon, Healon GV or HPMC) or without, using 90% and 150% energies respectively.
View Article and Find Full Text PDFPurpose: The aim of this study was to (1) develop suture techniques in repairing radial meniscal tear; (2) to compare the biomechanical properties of the proposed repair techniques with the conventional double horizontal technique.
Methods: Thirty-six fresh-frozen porcine medial menisci were randomly assigned into four groups and a complete tear was made at the midline of each meniscus. The menisci were subsequently repaired using four different repair techniques: double vertical (DV), double vertical cross (DVX), hybrid composing one vertical and one horizontal stitch, and conventional double horizontal (DH) suture technique with suturing parallel to the tibia plateau.
Background: Surgical stabilization of rib fractures is an established form of treatment for complex rib fractures. Plate fixation with bicortical screws placement can cause injury to intra-thoracic organs and pleural irritation from protruding screw tips. The aim of this study is to compare the biomechanical properties of monocortical and bicortical plate fixation for rib fractures using a locking plate system.
View Article and Find Full Text PDFClin Biomech (Bristol)
February 2019
Background: Cyclic testing of flexor tendons aims to simulate post-operative rehabilitation and is more rigorous than static testing. However, there are many different protocols, making comparisons difficult. We reviewed these protocols and suggested two protocols that simulate passive and active mobilization.
View Article and Find Full Text PDFBackground: To propose a new term ('construct efficiency') for the evaluation of multi strands flexor tendon repairs using different suture materials.
Methods: A total of twenty specimens from 4-0 braided polyblend sutures (FiberLoop/FiberWire; Arthrex, Naples, FL) and 4-0 nylon sutures (Supramid Extra II; S. Jackson, Inc.
J Hand Surg Eur Vol
November 2018
We compared the Lim/Tsai tendon repair technique using an extra-tendinous knot with modification using an intra-tendinous knot. The ultimate tensile strength, load to 2 mm gap force, stiffness, mode of failure, location of failure, and time taken to repair each tendon were recorded during a single cycle loading test in 20 tendons with each repair method. We found that the ultimate tensile strength and 2 mm gap force of the modified Lim/Tsai repair with an extra-tendinous knot (56 SD 5 N and 14 SD 2 N, respectively) were statistically significantly higher than that of the modified Lim/Tsai repair with intra-tendinous knot (51 SD 7 N and 11 SD 2 N, respectively).
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
September 2017
Purpose: To determine the effects of the Ziemer LDV Z8 liquid interface femtosecond laser platform during capsulotomy under different energy settings in the presence of corneal edema.
Methods: Cadaveric porcine eyes (n = 36) employed at less than 6 and greater than 24 post enucleation hours to simulate clear/edematous corneas, underwent capsulotomy with the Ziemer LDV Z8 femtosecond laser (5-mm diameter, energy 90%, 130%, or 150%). Lens capsules were removed for evaluation by scanning electron microscopy and rupture strengths determined by the single column universal testing system.
The Lim/Tsai tendon repair technique has been modified clinically to achieve a 6-strand repair using a single looped suture with one extratendinous knot. We compared biomechanical performance of the original and modified methods using 20 porcine flexor digitorum profundus tendons. The ultimate tensile strength, load to 2 mm gap force, mode of failure, and time taken to repair each tendon were recorded during a single cycle loading test in 10 tendons with each repair method.
View Article and Find Full Text PDFBackground: This study evaluated the biomechanical performance of a novel asymmetric 6-strand flexor tendon repair technique without locking loops.
Methods: Twenty porcine flexor tendons were equally repaired by using the asymmetric technique and compared with the modified Lim-Tsai repair technique. The ultimate tensile strength, load to 1-mm gap force, stiffness, and mechanism of failure were measured.
The introduction of femtosecond laser assisted cataract surgery (FLACS) is a paradigm changing approach in cataract surgery, the most commonly performed surgical procedure. FLACS has the potential to optimize the creation of an anterior lens capsulotomy, a critical step in accessing the cataractous lens. The merits of using a laser instead of a manual approach include a potentially more circular, consistent, and stronger aperture.
View Article and Find Full Text PDF