: This study explores the long-term clinical outcomes of antibiotic-impregnated calcium hydroxyapatite (CHA) as an antibiotic delivery system in treating periprosthetic joint infection (PJI) following total hip arthroplasty (THA). : We conducted a retrospective analysis of 12 patients (13 hips) who were treated with antibiotic-impregnated CHA for PJI after THA and followed for more than 10 years at our institution between 1999 and 2011. The study group comprised six men (seven hips) and six women, with a mean age of 61.
View Article and Find Full Text PDFIntroduction: Leg length is an important consideration in total hip arthroplasty (THA) as leg length discrepancies (LLD) after THA cause poor outcomes and medical litigation. This study aimed to investigate the accuracy of computed tomography (CT)-based navigation with augmented reality (AR) technology for measuring intra-operative leg length change using anteroposterior radiography (two-dimensional, 2D) and CT (three-dimensional, 3D).
Materials And Methods: This study included 71 patients (75 hips) who underwent primary cementless THA in the supine position between June 2022 and November 2023 using the HoloNavi One.
Introduction: We aimed to compare periprosthetic femoral bone remodeling after cementless total hip arthroplasty (THA) using a short-tapered wedge stem and a fully hydroxyapatite (HA)-coated stem.
Materials And Methods: In this retrospective study, 24 primary cementless THA procedures with short-tapered wedge stem and 24 using a fully HA-coated stem were performed. The follow-up duration was 2 years for both groups.
Objectives: The pain associated with osteoarthritis (OA) was thought to be nociceptive; however, neuropathic pain is also observed. We investigated the relationship between hip OA and neuropathic pain using the PainDETECT questionnaire (PDQ).
Methods: A total of 159 hips of 146 consecutive patients who underwent total hip arthroplasty (THA) with a diagnosis of OA were enrolled in this study.
Augmented reality (AR) has been used for navigation during total hip arthroplasty (THA). AR computed tomography (CT)-based navigation systems and AR-based portable navigation systems that use smartphones can also be used. This study compared the accuracy of cup insertion during THA using AR-CT-based and portable AR-based navigation systems.
View Article and Find Full Text PDFIntroduction: This study aimed to investigate the accuracy of cup position and assess the changes in pelvic tilt during primary total hip arthroplasty (THA) in the lateral decubitus position using a new computed tomography (CT)-based navigation system with augmented reality (AR) technology.
Materials And Methods: There were 37 cementless THAs performed using a CT-based navigation system with AR technology in the lateral decubitus position and 63 cementless THAs performed using manual implant techniques in the lateral decubitus position in this retrospective study. Postoperative cup radiographic inclination and anteversion were measured using postoperative CT, and the proportion of hips within Lewinnek's safe zone was analyzed and compared between the two groups.
: This study aimed to report the long-term outcomes of total hip arthroplasty (THA) using a Conserve Plus (Wright Medical, Japan) metal-on-metal (MoM) acetabular prosthesis with a modular neck stem. : This study enrolled 50 patients (10 men and 40 women; mean age, 65.8 (39-87) years) who underwent primary THA using a Conserve Plus MoM acetabular prosthesis with a modular neck stem.
View Article and Find Full Text PDFRobot-assisted total knee arthroplasty (TKA) has proven to be successful in improving the accuracy of component positioning and reducing radiographic outliers. This study aimed to evaluate and compare the alignment of the components using two- and three-dimensional (2D and 3D) measurements following handheld imageless robot-assisted TKA. Seventy consecutive patients underwent primary TKA at our institution using a handheld robot-assisted system.
View Article and Find Full Text PDFThis study aimed to compare the cutting and component placement accuracies and early outcomes after total knee arthroplasty (TKA) between an image-free handheld robotic system (NAVIO) and a radiography-based robotic system (ROSA). This retrospective study included 88 patients (88 knees) who underwent TKA using the NAVIO (40 patients) or ROSA (48 patients) robotic systems. The accuracies of the robotic systems were compared.
View Article and Find Full Text PDFThe purpose of this study was to evaluate the mid-term clinical results and polyethylene wear of vitamin E-diffused highly cross-linked polyethylene (HXLPE) and 2-methacryloyloxyethyl phosphorylcholine (MPC)-grafted HXLPE in cementless total hip arthroplasty (THA). Thirty-four THAs with vitamin E-diffused HXLPE (VEPE) and 32-mm cobalt-chromium head, and 116 THAs with MPC-grafted HXLPE and 32-mm alumina head were evaluated. The Merle d'Aubigné and Postel scores were administered.
View Article and Find Full Text PDFPortable navigation systems have been developed for use in total hip arthroplasty (THA) in recent years. Although intraoperative registration in the lateral decubitus position or the supine position is need to create the three-dimensional coordinate system, it is not clear which position is appropriate. The purpose of this study was to assess the accuracy of cup placement in primary THA in the lateral decubitus position using an image-free handheld navigation device with registration in the lateral decubitus or the supine position, and clarify which position is appropriate.
View Article and Find Full Text PDFBackground: The aim of this study was examining the accuracy of accelerometer-based portable navigation systems (HipAlign) when measuring leg length changes using two-dimensional (2D) and three-dimensional (3D) methods.
Methods: Inclusion criteria were patients ≥ 20 years old with symptomatic hip disease who underwent primary total hip arthroplasty (THA) in the supine position using HipAlign between June 2019 and April 2020. The exclusion criteria were patients who underwent THA via a posterior approach.
Purpose: Hemi-resurfacing arthroplasty (Hemi) and metal-on-metal hip resurfacing arthroplasty (HR) were proposed as alternatives to conventional total hip arthroplasty (THA) for patients with osteonecrosis of the femoral head (ONFH). Long-term results were evaluated.
Methods: Twenty-three hips with ONFH were treated, using Hemi in 12 and HR in 11.
To clarify the association between pre- and postoperative rotational mismatches of the femorotibial components and bones for total knee arthroplasty (TKA) with bi-cruciate retaining (BCR) design and with fixed bearing posterior stabilized (PS) design. This retrospective cohort study included 40 BCR TKAs and 50 PS TKAs. Pre- and postoperative rotational mismatches of the femorotibial components and bones were measured by three-dimensional assessment based on computed tomography imaging.
View Article and Find Full Text PDFBackground: Augmented reality (AR) provides the surgeon with direct visualization of radiological images by overlaying them on the patient. This study aimed to evaluate the accuracy of cup placement using a computed tomography (CT)-based AR navigation system.
Methods: Sixty-five prospectively enrolled patients underwent primary cementless total hip arthroplasty (THA) in a supine position using this novel AR navigation system, and changes in pelvic flexion angle (PFA) were evaluated.
Background: This study aimed to examine the component positioning and early clinical outcomes in total knee arthroplasty (TKA) using an imageless hand-held robotic-assisted system compared with those without robotics.
Methods: Component positioning, hip-knee-ankle angle (HKA), and clinical outcome 1-year postoperatively were compared between 40 patients who underwent TKA with Navio (robot group) and 40 control patients who underwent TKA with a jig-based technique (manual group). The clinical outcomes evaluated were range of motion and the 2011 Knee Society Score.
Background: Patient satisfaction and expectations are now recognized as an outcome measure for successful total knee arthroplasty (TKA). The purpose of this study was to determine which factors including soft tissue balance during surgery affect patient satisfaction and expectations after TKA.
Methods: A total of 135 patients (157 knees) with knee osteoarthritis who underwent primary TKA with a posterior stabilized design were studied.
We assessed the clinical results of irrigation and debridement (I&D) with antibiotic-impregnated calcium hydroxyapatite (CHA) as a novel antibiotic delivery system for the treatment of prosthetic-joint-associated infection (PJI) after total hip arthroplasty (THA). Thirteen patients (14 hips) treated with I&D for PJI after THA at our institution between 1997 and 2017 were retrospectively evaluated. The study group included four men (five hips) and nine women, with an average age of 66.
View Article and Find Full Text PDFMaterials (Basel)
March 2023
Ultra-high-molecular-weight polyethylene (UHMWPE) wear and particle-induced osteolysis contribute to the failure of total hip arthroplasty (THA) and total knee arthroplasty (TKA). Highly crosslinked polyethylene (HXLPE) was developed in the late 1990s to reduce wear and has shown lower wear rates and loosening than conventional UHMWPE in THA. The irradiation dose for crosslinking is up to 100 kGy.
View Article and Find Full Text PDFBackground: this study aimed to assess the long-term outcomes of (a minimum of 10-years) total hip arthroplasty with a metal-on-metal acetabular prosthesis. Methods: Eighty-nine primary total hip arthroplasties (82 patients) were performed using a Pinnacle modular metal-on-metal acetabular prosthesis. Clinical hip function outcomes were evaluated using the Japanese Orthopaedic Association hip score preoperatively and at the final follow-up.
View Article and Find Full Text PDFObjectives: The objective of the study is to evaluate the relationship between clinical results following posterior-stabilized total knee arthroplasty (TKA) and intraoperative kinematic pattern determined from navigation.
Methods: Participants were patients with knee osteoarthritis and varus deformity who underwent primary posterior-stabilized TKA. Preoperative and post-implantation kinematic data were recorded, and all kinematic patterns were divided into two types: medial pivot (MP) or non-MP.
Background: The purpose of this study was to compare component alignment using two-dimensional (2D) and three-dimensional (3D) measurements following total knee arthroplasty (TKA) with a new robotic system.
Methods: A total of 38 patients underwent TKA with the robotic system. Cutting errors were measured.
The aim of this study was to compare acetabular offset, femoral offset, and global offset measurements obtained after total hip arthroplasty (THA) between a two-dimensional (2D) method and a three-dimensional (3D) method. The subjects were 89 patients with unilateral osteoarthritis who underwent primary THA at our institution. Acetabular, femoral, and global offsets were measured by each of the 2D and 3D methods in native and implanted hips.
View Article and Find Full Text PDFBackground: This study aimed to determine the accuracy of acetabular cup insertion using a novel accelerometer-based navigation system in total hip arthroplasty (THA).
Methods: A single-surgeon study was conducted in which 62 prospective patients with navigation and 42 retrospective patients without navigation in a supine position were compared. Absolute values for errors of radiographic inclination and anteversion were calculated.
Knee Surg Sports Traumatol Arthrosc
February 2023