Publications by authors named "Yixiao Zhao"

Background: We prospectively assessed the reproducibility of a novel low-dose single-volume dynamic computed tomography (CT) myocardial blood flow measurement technique.

Methods: Thirty-four pairs of measurements were made under rest and stress conditions in 13 swine (54.3 ± 12.

View Article and Find Full Text PDF

Rationale And Objectives: To improve the image quality of CT pulmonary angiography (CTPA) using a patient-specific timing protocol.

Material And Methods: A total of 24 swine (48.5 ± 14.

View Article and Find Full Text PDF

Background: To evaluate the reproducibility of a vessel-specific minimum cost path (MCP) technique used for lobar segmentation on noncontrast computed tomography (CT).

Methods: Sixteen Yorkshire swine (49.9 ± 4.

View Article and Find Full Text PDF

Background: Approximately 10-15% of inflammatory bowel disease (IBD) patients with overlapping features of ulcerative colitis (UC) and Crohn's disease (CD) are termed as inflammatory bowel disease unclassified (IBDU). This study aimed to describe the clinical features of IBDU and evaluate the potential associated factors of reclassification.

Methods: The clinical data of 37 IBDU patients were retrospectively analyzed from November 2012 to November 2020.

View Article and Find Full Text PDF

Background CT lymphangiography has been used to image the lymphatic anatomy and assess lymphatic abnormalities. There is, however, a need to develop a method for quantification of lymphatic flow rate in the thoracic duct (TD). Purpose To develop and validate a TD lymphatic flow measurement technique using dynamic contrast-enhanced CT lymphangiography.

View Article and Find Full Text PDF

Background: Computed tomography pulmonary angiography (CTPA) is the primary modality for the detection and diagnosis of pulmonary embolism (PE) while the stratification of PE severity remains challenging using angiography. Hence, an automated minimum-cost path (MCP) technique was validated to quantify the subtended lung tissue distal to emboli using CTPA.

Methods: A Swan-Ganz catheter was placed in the pulmonary artery of seven swine (body weight: 42.

View Article and Find Full Text PDF

Objectives: The objective was to retrospectively develop a protocol in swine for optimal contrast media timing in coronary CT angiography (CCTA).

Methods: Several dynamic acquisitions were performed in 28 swine (55 ± 24 kg) with cardiac outputs between 1.5 and 5.

View Article and Find Full Text PDF

Natural killer (NK) cells are lymphocytes and play a pivotal role in innate and adaptive immune responses against infections and malignancies. Longitudinal studies have indicated the feasibility of perinatal blood for large-scale NK cell generation, yet the systematic and detailed comparations of the signatures of resident and expanded NK cells (rNKs, eNKs) are largely obscure. Herein, we harvested rNKs from umbilical cord blood (rUC-NKs) and placental blood (rP-NKs) as well as the corresponding eNKs (eUC-NKs, eP-NKs).

View Article and Find Full Text PDF

The purpose of this study is to develop and validate an optimal timing protocol for a low-radiation-dose CT pulmonary perfusion technique using only two volume scans. A total of 24 swine (48.5 ± 14.

View Article and Find Full Text PDF

Objective: Hypertension (HT) induces left atrial (LA) and left ventricular (LV) dysfunction, and an increase in arterial stiffness. In this study, we investigated the association between LA-LV-arterial coupling and nighttime systolic blood pressure (BP) as well as BP circadian rhythm in essential hypertension.

Methods: We enrolled 290 HT patients.

View Article and Find Full Text PDF

Rationale And Objectives: To validate the accuracy of a novel low-dose dynamic CT perfusion technique in a swine model using fluorescent microsphere measurement as the reference standard.

Materials And Methods: Contrast-enhanced dynamic CT perfusion was performed in five swine at baseline and following brain embolization. Reference microspheres and intravenous contrast (370 mg/ml iodine, 1 ml/kg) were injected (5 ml/s), followed by dynamic CT perfusion.

View Article and Find Full Text PDF

Objective: We examined the associations among the circadian rhythms of blood pressure (BP), heart rate (HR) and left atrial function in essential hypertensive patients.

Methods: The study included 237 essential hypertensive patients who completed 24-h ambulatory BP, HR monitoring and two-dimensional speckle tracking echocardiography (2DSTE). The strain and strain rate images were studied, and the following parameters were measured: left atrial reservoir strain and strain rate (LAS-S and LASR-S), left atrial conduit strain and strain rate (LAS-E and LASR-E), and left atrial booster strain and strain rate (LAS-A and LASR-A).

View Article and Find Full Text PDF

Purpose: Small airways with inner diameters less than 2 mm are sites of major airflow limitations in patients with chronic obstructive pulmonary disease (COPD) and asthma. The purpose of this study is to investigate the limitations for accurate assessment of small airway dimensions using both high-resolution CT (HRCT) and conventional normal-resolution CT at low dose levels.

Methods: To model the normal human airways from the 3rd to 20th generations, a cylindrical polyurethane phantom with 14 airway tubes of inner diameters (ID) ranging from 0.

View Article and Find Full Text PDF

Thymic blood vessels at the perivascular space (PVS) are the critical site for both homing of hematopoietic progenitor cells (HPCs) and egress of mature thymocytes. It has been intriguing how different opposite migrations can happen in the same place. A subset of specialized thymic portal endothelial cells (TPECs) associated with PVS has been identified to function as the entry site for HPCs.

View Article and Find Full Text PDF

Morphological and physiological assessment of coronary artery disease (CAD) is necessary for proper stratification of CAD risk. The objective was to evaluate a low-dose cardiac CT technique that combines morphological and physiological assessment of CAD. The low-dose technique was evaluated in twelve swine, where three of the twelve had coronary balloon stenosis.

View Article and Find Full Text PDF

This study aimed to evaluate left atrial (LA) mechanics using two-dimensional speckle-tracking echocardiography (2DSTE) and investigate their correlations with measures of target organ damage (TOD) in hypertension. We enrolled 42 healthy controls (Group I) and 286 hypertension patients: Group II (n = 79) had an LA volume index (LAVI) <28 ml/m; Group III (n = 92) had an LAVI ≥28 ml/m; and Group IV (n = 115) had hypertension with left ventricular hypertrophy (LVH). We measured the following parameters: LA reservoir strain and strain rate (LA, LA), LA conduit strain and strain rate (LA and LA), and LA booster strain and strain rate (LA and LA).

View Article and Find Full Text PDF

Purpose: To evaluate the accuracy of a low-dose first-pass analysis (FPA) CT pulmonary perfusion technique in comparison to fluorescent microsphere measurement as the reference standard.

Method: The first-pass analysis CT perfusion technique was validated in six swine (41.7 ± 10.

View Article and Find Full Text PDF

Objectives: The aim of this study was to assess the feasibility of a prospective first-pass analysis (FPA) dynamic computed tomography (CT) perfusion technique for accurate low-radiation-dose global stress perfusion measurement.

Materials And Methods: The prospective FPA technique was evaluated in 10 swine (42 ± 12 kg) by direct comparison to a previously validated retrospective FPA technique. Of the 10 swine, 3 had intermediate stenoses with fractional flow reserve severities of 0.

View Article and Find Full Text PDF

Assembly quality is the barometer of assembly system health, and a healthy assembly system is an important physical guarantee for producing reliable products. Therefore, for ensuring the high reliability of products, the operational data of the assembly system should be analyzed to manage health states. Therefore, based on the operational data of the assembly system collected by intelligent sensors, from the perspective of quality control based on risk thinking, a risk-oriented health assessment method and predictive maintenance strategy for managing assembly system health are proposed.

View Article and Find Full Text PDF

Background: Myocardial perfusion measurement with a low-dose first-pass analysis (FPA) dynamic computed tomography (CT) perfusion technique depends upon acquisition of two whole-heart volume scans at the base and peak of the aortic enhancement. Hence, the objective of this study was to validate an optimal timing protocol for volume scan acquisition at the base and peak of the aortic enhancement.

Methods: Contrast-enhanced CT of 28 Yorkshire swine (weight, 55 ± 24 kg, mean ± standard deviation) was performed under rest and stress conditions over 20-30 s to capture the aortic enhancement curves.

View Article and Find Full Text PDF

The rapid development of complexity and intelligence in manufacturing systems leads to an increase in potential operational risks and therefore requires a more comprehensive system-level health diagnostics approach. Based on the massive multi-source operational data collected by smart sensors, this paper proposes a mission reliability-driven manufacturing system health state evaluation method. Characteristic attributes affecting the mission reliability are monitored and analyzed based on different sensor groups, including the performance state of the manufacturing equipment, the execution state of the production task and the quality state of the manufactured product.

View Article and Find Full Text PDF

Rationale And Objectives: The accuracy of coronary computed tomography (CT) angiography depends upon the degree of coronary enhancement as compared to the background noise. Unfortunately, coronary contrast-to-noise ratio (CNR) optimization is difficult on a patient-specific basis. Hence, the objective of this study was to validate a new combined diluted test bolus and CT angiography protocol for improved coronary enhancement and CNR.

View Article and Find Full Text PDF

Background: There is limited understanding of the clinical characteristics of different radiological forms of autoimmune pancreatitis (AIP). This retrospective study compared the clinical features of radiological forms of AIP.

Methods: A retrospective review was conducted of patients with AIP treated from 2005 to 2015.

View Article and Find Full Text PDF
Autoimmune Pancreatitis:Typing,Diagnosis,and Treatment.

Zhongguo Yi Xue Ke Xue Yuan Xue Bao

December 2016

Autoimmune pancreatitis (AIP),a special type of chronic pancreatitis,is autoimmune-mediated and can be accompanied by swelling of the pancreas and irregular stenosis of the pancreatic duct. The main pathological features are fibrosis of pancreatic duct with IgG4-positive lymphoplasmacytic infiltration. Different typing methods of AIP can have differerent disease conditions.

View Article and Find Full Text PDF

Objective To summarize the clinical features,management,and outcome of ulcerative colitis (UC) complicated with opportunistic infections in the elderly patients. Methods The clinical data of 43 elderly UC patients in Peking Union Medical College Hospital from 2006 to 2016 were retrospectively analyzed. These patients were divided into two groups for comparisons:the infection group (complicated with opportunistic infection,n=14) and control group (without opportunistic infection,n=29).

View Article and Find Full Text PDF