The detection of hidden explosives through their odors is of great importance to law enforcement agencies and trained canines have traditionally been used for this purpose. This paper reports the extraction of odor signature compounds characteristic of smokeless powders, followed by their detection by ion mobility spectrometers (IMS). Such a method enables the detection of odor compounds, complementing canine detection and allows for mass calibration of IMS instruments.