Publications by authors named "Yinghua Shao"
Article Synopsis
- The reactor coolant pump is crucial in preventing overheating and shutdown in nuclear power plants, and leakage issues can stem from corrosion or scaling.
- An integrated method is proposed that involves analyzing the cross-sectional area of the first seal to detect leakage and predict remaining useful life (RUL) through a combination of physical and data-driven models.
- The approach demonstrates high accuracy and efficiency, with excellent rates for degradation point detection and fault mode diagnosis, validated using real data from six reactor coolant pumps.
View Article and Find Full Text PDF