Rapid and accurate molecular diagnostics are crucial for preventing the global spread of emerging infectious diseases. However, the current gold standard for nucleic acid detection, reverse transcription polymerase chain reaction (RT-PCR), relies heavily on traditional magnetic beads or silica membranes for nucleic acid extraction, resulting in several limitations, including time-consuming processes, the need for trained personnel, and complex equipment. Therefore, there is an urgent need for fully integrated nucleic acid detection technologies that are simple to operate, rapid, and highly sensitive to meet unmet clinical needs.
View Article and Find Full Text PDFAdministration of AAV-based gene therapies into the intra-cerebrospinal fluid (CSF) compartments via routes such as lumbar puncture (LP) has been implemented as an alternative to intravenous dosing to target the CNS regions. This route enables lower doses, decreases systemic toxicity, and circumvents intravascular pre-existing anti-AAV antibodies. In this study, AAV9-GFP vectors were administered via LP to juvenile cynomolgus macaques with and without pre-existing serum anti-AAV9 antibodies at a 5.
View Article and Find Full Text PDFHighly sensitive airborne virus monitoring is critical for preventing and containing epidemics. However, the detection of airborne viruses at ultra-low concentrations remains challenging due to the lack of ultra-sensitive methods and easy-to-deployment equipment. Here, we present an integrated microfluidic cartridge that can accurately detect SARS-COV-2, Influenza A, B, and respiratory syncytial virus with a sensitivity of 10 copies/mL.
View Article and Find Full Text PDFEmerging diagnostic scenarios, such as population surveillance by pooled testing and on-site rapid diagnosis, highlight the importance of advanced microfluidic systems for in vitro diagnostics. However, the widespread adoption of microfluidic technology faces challenges due to the lack of standardized design paradigms, posing difficulties in managing macro-micro fluidic interfaces, reagent storage, and complex macrofluidic operations. This paper introduces a novel modular-based mesoscopic design paradigm, featuring a core "needle-plug/piston" structure with versatile variants for complex fluidic operations.
View Article and Find Full Text PDFCervical cancer is among the most common malignant tumors in women. The development of rapid screening techniques plays an important role in early screening for cancer treatment. We have developed an HPV screening method, which effectively combines the high-efficiency nucleic acid enrichment of chitosan-modified filter paper and the rapid visual detectability of colorimetric LAMP, along with the enhancement of the tolerance ability of the pH-sensitive LAMP reagent to acidic original samples, making the detection of HPV 16/18 easy to carry out and reliable, which is helpful for the epidemiological prevention and control strategies of HPV-induced cancer.
View Article and Find Full Text PDFSomatic mutation is a valuable biomarker for tracking tumor progression and migration due to its distinctive feature in various tumors and its wide distribution throughout body fluids. However, accurately detecting somatic mutations from the abundant DNA of noncancerous origins remains a practical challenge in the clinic. Herein, we developed an ultraspecific method, called tweezer PCR, for detecting low-abundance mutations inspired by the design of DNA origami.
View Article and Find Full Text PDFRisk management and control of airborne transmission in hospitals is crucial in response to a respiratory virus pandemic. However, the formulation of these infection control measures is often based on epidemiological investigations, which are an indirect way of analyzing the transmission route of viruses. This can lead to careless omissions in infection prevention and control or excessively restrictive measures that increase the burden on healthcare workers.
View Article and Find Full Text PDFLINC01354 is a long non-coding RNA (lncRNA) highly expressed in gastric cancer (GC). However, studies have shown that it plays a critical role in the progression of other tumors. This study attempts to uncover the role of LINC01354 in GC.
View Article and Find Full Text PDFSurveillance of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in aquatic environments attracted attention due to its considerable impacts on human health and ecology, especially in countries with poor sanitation standards. Based on a strategy of one-stop extraction and amplification, we developed an ultrasensitive method that uses a polyacrylamide derivative-modified filter disc (PAD-FD), in which highly diluted RNA can be efficiently concentrated onto the filter disc and directly used for amplification. A newly designed spin column with a cup-like filter base facilitated the non-contact transfer of the affinity filter disc from the column to a PCR tube.
View Article and Find Full Text PDFInt J Environ Res Public Health
November 2022
In workplaces such as steel, power grids, and construction, firefighters and other workers often encounter non-uniform high-temperature environments, which significantly increase the risk of local heat stress and local heat discomfort for the workers. In this paper, a multi-segment human bioheat model is developed to predict the human thermal response in asymmetric high-temperature environments by considering the sensitivity of the modeling to angular changes in skin temperature and the effects of high temperatures on human thermoregulatory and physiological responses simultaneously. The extended model for asymmetric high-temperature environments is validated with the current model results and experimental data.
View Article and Find Full Text PDFAirborne transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has highlighted the urgent need for aerosol monitoring of SARS-CoV-2 to prevent sporadic outbreaks of COVID-19. The inadequate sensitivity of conventional methods and the lack of an on-site detection system limited the practical SARS-CoV-2 monitoring of aerosols in public spaces. We have developed a novel SARS-CoV-2-in-aerosol monitoring system (SIAMs) which consists of multiple portable cyclone samplers for collecting aerosols from several venues and a sensitive "sample-to-answer" microsystem employing an integrated cartridge for the analysis of SARS-CoV-2 in aerosols (iCASA) near the sampling site.
View Article and Find Full Text PDFAims: Benign prostatic hyperplasia (BPH) is a progressive disease, which severely affects men's health. Here, we sought to analyze the functions and mechanism of action of the tripartite motif protein 52 (TRIM52), a novel prostate basal cell biomarker in BPH.
Materials And Methods: Immunohistochemistry assay was performed in sectioned human BPH tissues, BPH-1 cells, and prostate RWPE-1 cells, to detect the expressions of TRIM52 and NF-κB.
Microfluidics is facing critical challenges in the quest of miniaturizing, integrating, and automating in vitro diagnostics, including the increasing complexity of assays, the gap between the macroscale world and the microscale devices, and the diverse throughput demands in various clinical settings. Here, a "3D extensible" microfluidic design paradigm that consists of a set of basic structures and unit operations was developed for constructing any application-specific assay. Four basic structures-check valve (in), check valve (out), double-check valve (in and out), and on-off valve-were designed to mimic basic acts in biochemical assays.
View Article and Find Full Text PDFIn today's research environment, children's diet, physical activity, and other lifestyle factors are commonly studied in the context of health, independent of their effect on cognition and learning. Moreover, there is little overlap between the two literatures, although it is reasonable to expect that the lifestyle factors explored in the health-focused research are intertwined with cognition and learning processes. This thematic review provides an overview of knowledge connecting the selected lifestyle factors of diet, physical activity, and sleep hygiene to children's cognition and learning.
View Article and Find Full Text PDFThe realization of an automated short tandem repeat (STR) analysis for forensic investigations is facing a unique challenge, that is DNA evidence with wide disparities in sample types, quality, and quantity. We developed a fully integrated microsystem in a modular-based architecture to accept and process various forensic samples in a "sample-in-answer-out" manner for forensic STR analysis. Two sample preparation modules (SPMs), the direct and the extraction SPM, were designed to be easily assembled with a capillary array electrophoresis (CAE) chip using a chip cartridge to efficiently achieve an adequate performance to different samples at a low cost.
View Article and Find Full Text PDFA pipette-actuated capillary array comb (PAAC) system operated on a smartphone-based hand-held device has been successfully developed for the multiplex detection of bacteria in a "sample-to-answer" manner. The PAAC consists of eight open capillaries inserted into a cylindrical plastic base with a piece of chitosan-modified glass filter paper embedded in each capillary. During the sample preparation, a PAAC was mounted into a 1 mL pipette tip with an enlarged opening and was operated with a 1 mL pipette for liquid handling.
View Article and Find Full Text PDFThe chemokine receptor CXCR4 is highly expressed and associated with poor prognosis in multiple malignancies. Upon engagement by its ligand, CXCL12, CXCR4 triggers intracellular signaling pathways that control trafficking of cells to tissues where the ligand is expressed, such as the bone marrow (BM). In hematologic cancers, CXCR4-driven homing of malignant cells to the BM protective niche is a key mechanism driving disease and therapy resistance.
View Article and Find Full Text PDFAn integrated graphene oxide purification-lateral flow test strip (iGOP-LFTS) was developed for on-strip purifying and visually detecting polymerase chain reaction (PCR) products with an improved sensitivity as well as a more stringent specificity. PCR products amplified with a pair of biotin- and digoxin-labeled primers were directly pipetted onto GO pads, on which graphene oxide selectively adsorbed residual primers and primer-dimers with the aid of a running buffer containing MgCl and Tween 20. By stacking up three GO pads to increase the surface area for adsorption, 83.
View Article and Find Full Text PDFThe chemokine receptor CXCR4 mediates cell anchorage in the bone marrow (BM) microenvironment and is overexpressed in 25-30% of patients with acute myeloid leukemia (AML). Here we have shown that a new CXCR4 receptor antagonist IgG1 antibody (PF-06747143) binds strongly to AML cell lines and to AML primary cells inhibiting their chemotaxis in response to CXCL12. PF-06747143 also induced cytotoxicity in AML cells via Fc-effector function.
View Article and Find Full Text PDFBackground: The efficacy of intravenous (IV) acetaminophen compared with its oral formulation for postoperative analgesia is unknown. We hypothesized that the addition of acetaminophen to a multimodal analgesia regimen would provide improved pain management in patients after total knee arthroplasty (TKA) and that the effect of acetaminophen would be variable based on the route of delivery.
Methods: The study was a single-center, randomized, double-blinded, placebo-controlled clinical trial on the efficacy of IV vs oral acetaminophen in patients undergoing unilateral TKA.
Background: The CXCR4-CXCL12 axis plays an important role in the chronic lymphocytic leukemia (CLL)-microenvironment interaction. Overexpression of CXCR4 has been reported in different hematological malignancies including CLL. Binding of the pro-survival chemokine CXCL12 with its cognate receptor CXCR4 induces cell migration.
View Article and Find Full Text PDFPlastic microfluidic devices with embedded chitosan-modified Fusion 5 filter paper (unmodified one purchased from GE Healthcare) have been successfully developed for DNA extraction and concentration, utilizing two different mechanisms for DNA capture: the physical entanglement of long-chain DNA molecules with the fiber matrix of the filter paper and the electrostatic adsorption of DNA to the chitosan-modified filter fibers. This new method not only provided a high DNA extraction efficiency at a pH of 5 by synergistically combining these two capture mechanisms together, but also resisted the elution of DNA from filters at a pH > 8 due to the entanglement of DNA with fibers. As a result, PCR buffers can be directly loaded into the extraction chamber for "in situ PCR", in which the captured DNA were used for downstream analysis without any loss.
View Article and Find Full Text PDF