Anaerobic electrochemical digestion (AED) is an effective system for recovering biogas from organic wastes. However, the effects of different anode potentials on anaerobic activated sludge remain unclear. This study confirmed that biofilms exhibited the best electroactivity at -0.

View Article and Find Full Text PDF

The proliferation of emerging contaminants (ECs) in the environment poses a major threat to the safety of reuse water. However, many ECs exist for which no corresponding control standards have been established. Here, we used polarity reversal to construct a biocathode sensor capable of early warning of ECs biotoxicity in aerobic reuse water with low organic concentrations.

View Article and Find Full Text PDF

Biochemical oxygen demand (BOD) is a key indicator of water quality. However, there is still no technique to directly measure BOD at low concentrations in oxygen-rich environments. Here, we propose a new scheme using facultative electrotrophs as the sensing element, and confirmed aerobic Acinetobacter venetianus RAG-1 immobilized on electrode was able to measure BOD via the switchover between electrotrophic and heterotrophic respirations.

View Article and Find Full Text PDF

As a result of the 2019 coronavirus pandemic, disinfection byproducts generated by the extensive use of chlorine disinfectants have infiltrated the aquatic environment, severely threatening ecological safety and human health. Therefore, the accurate monitoring of the biotoxicity of aqueous environments has become an important issue. Biocathode sensors are excellent choices for toxicity monitoring because of their special electroautotrophic respiration functions.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to explore the clinical effect of the novel method combined longitudinal S-osteotomy and Lengthen And Then Nail (LATN) technique for leg lengthening and compare with the classic Ilizarov method.

Methods: This retrospective study was performed from March 2008 to April 2012. A total of 176 leg lengthenings (88 consecutive patients) were performed at our institution.

View Article and Find Full Text PDF

Objective: To shorten the time of external skeletal fixation on legs, and enhance quality of limb lengthening, avoid complications of shortening, bending, twisting and etc.

Methods: Insert pin transcortical to attack external skeletal fixation simultaneously, put un-reaming locked intramedullary nail (do not insert distal locked screw) into endosteum of lengthening bone. After the legs achieved predetermined length, insert distal locked screw and then remove external skeletal fixation, locked intramedullary nail, then maintain consolidation of rehabilitation.