Publications by authors named "Yasuo Takehara"

Background: Portal vein thrombosis (PVT) is thought to arise from stagnant blood flow, yet conclusive evidence is lacking. Relative residence time (RRT) assessed using 4D Flow MRI may offer insight into portal flow stagnation.

Purpose: To explore the relationship between RRT values and the presence of PVT in cirrhotic participants.

View Article and Find Full Text PDF

Background Percutaneous transhepatic portal vein (PV) embolization (PVE) is a standard preoperative procedure for advanced biliary cancer when the future liver remnant (FLR) is insufficient, yet the effect of this procedure on portal hemodynamics is still unclear. Purpose To assess whether four-dimensional (4D) MRI flowmetry can be used to estimate FLR volume and to identify the optimal time for this measurement. Materials and Methods This prospective single-center study enrolled consecutive adult patients with biliary cancer who underwent percutaneous transhepatic PVE for the right liver between June 2020 and November 2022.

View Article and Find Full Text PDF

Objective: To predict sac enlargement with type II endoleak (ELII) before endovascular aneurysm repair (EVAR) using four dimensional flow sensitive magnetic resonance imaging (4D flow MRI).

Methods: A single centre retrospective analysis of prospectively collected data was conducted. Patients with an abdominal aortic aneurysm (AAA) who underwent EVAR between 2013 and 2019 were included.

View Article and Find Full Text PDF

Thus far, ultrasound, CT, and 2D cine phase-contrast MRI has been adopted to evaluate blood flow and vascular morphology in the portal venous system; however, all these techniques have some shortcomings, such as limited field of view and difficulty in accurately evaluating blood flow. A new imaging technique, namely 3D cine phase-contrast (4D Flow) MRI, can acquire blood flow data of the entire abdomen at once and in a time-resolved manner, allowing visual, quantitative, and comprehensive assessment of blood flow in the portal venous system. In addition, a retrospective blood flow analysis, i.

View Article and Find Full Text PDF

Background: Although endovascular aneurysmal repair (EVAR) is a preferred treatment for abdominal aortic aneurysm (AAA) owing to its low invasiveness, its impact on the local hemodynamics has not been fully assessed.

Purpose: To elucidate how EVAR affects the local hemodynamics in terms of energy loss (EL).

Study Type: Prospective single-arm study.

View Article and Find Full Text PDF

Background Changing iodinated contrast media (ICM) may reduce the risk of recurrent ICM-induced hypersensitivity reactions in patients with a prior reaction. Purpose To perform a systematic review on the effectiveness of ICM change in comparison with no change to prevent recurrent ICM immediate hypersensitivity reactions. Materials and methods Multiple data bases were searched without language restriction between January 1990 and August 2021 to identify comparative studies of any design that included patients with a prior ICM hypersensitivity reaction to low-osmolality ICM and re-exposure to intravascular ICM.

View Article and Find Full Text PDF

This special issue of Magnetic Resonance in Medical Sciences features the most recent reviews on 4D Flow MRI. These reviews deal with the current status of the emerging technique of 4D Flow MRI facilitated in various areas that are difficult to obtain with conventional flowmetry. MR signals inherently contain flow velocity information.

View Article and Find Full Text PDF
Article Synopsis
  • Blood vessels act like independent organs, with endothelial cells detecting blood flow conditions and adjusting flow by releasing various substances.
  • Changes in blood flow, particularly wall shear stress (WSS), can lead to health issues like atherosclerosis, which is linked to serious conditions such as abdominal aortic aneurysms and aortic dissection.
  • The importance of understanding abdominal aortic hemodynamics is highlighted, and 4D flow MRI is recommended for accurately measuring blood flow characteristics and aiding in diagnosis and treatment.
View Article and Find Full Text PDF

3D cine phase-contrast (4D flow) MRI is a sequence with great potential for non-invasive time-resolved 3D flowmetry at arbitrary vessel sections in various blood vessels. However, it is not widely known that the flowmetry with 4D flow MRI is vulnerable to pulsatile and non-uniform flow. Due to the limited spatial and temporal resolutions, averaging within the 3D voxel is occurring during the flowmetry.

View Article and Find Full Text PDF

Blood flow imaging becomes an emerging trend in cardiology with the recent progress in computer technology. It not only visualizes colorful flow velocity streamlines but also quantifies the mechanical stress on cardiovascular structures; thus, it can provide the detailed inspections of the pathophysiology of diseases and predict the prognosis of cardiovascular functions. Clinical applications include the comprehensive assessment of hemodynamics and cardiac functions in echocardiography vector flow mapping (VFM), 4D flow MRI, and surgical planning as a simulation medicine in computational fluid dynamics (CFD).

View Article and Find Full Text PDF

Recently, the hemodynamic assessments with 3D cine phase-contrast (PC) MRI (4D flow MRI) have attracted considerable attention from clinicians. Unlike 2D cine PC MRI, the technique allows for cardiac phase-resolved data acquisitions of flow velocity vectors within the entire FOV during a clinically viable period. Thus, the method has enabled retrospective flowmetry in the spatial and temporal axes, which are essential to derive hemodynamic parameters related to vascular homeostasis and those to the progression of the pathologies.

View Article and Find Full Text PDF

Aims: This study aimed to investigate the intraventricular blood flow pattern of patients with left bundle branch block (LBBB) using four-dimensional flow magnetic resonance imaging (4D-flow MRI).

Methods And Results: We performed 4D-flow MRI for 16 LBBB patients (LBBB group) and 16 propensity score-matched patients with a normal QRS duration (non-LBBB group). The energy loss (EL) in the left ventricle was evaluated.

View Article and Find Full Text PDF

A 59-year-old man with jaundice and lower common bile duct stenosis was referred to our institution for diagnosis and treatment. Computed tomography and magnetic resonance imaging showed a well-circumscribed smoothly marginated solid mass lesion in the pancreatic head. He underwent pyloric preserving pancreatoduodenectomy.

View Article and Find Full Text PDF

A man in his 50s with Budd-Chiari syndrome diagnosed with the suprahepatic inferior vena cava (IVC) obstruction on CT was assessed using 4D Flow MRI before and after balloon angioplasty. 4D Flow MRI acquired in two respiratory phases, depicted complex hemodynamic and respiratory variability, and a jet stream at the narrowed channel of the membranous IVC. Post-interventional 4D Flow MRI showed that the IVC blood flow increased with corrected flow directions in the infrarenal IVC.

View Article and Find Full Text PDF
Article Synopsis
  • * Doctors use special scans called CT and MRI to look for signs of AIP, which can make the pancreas look swollen like a sausage and show other unique features.
  • * The article talks about new ways to improve CT and MRI scans that could help doctors diagnose AIP better, like checking how easily tissues move and how well blood flows.
View Article and Find Full Text PDF

Purpose: To elucidate MRI features of primary hepatic mucosa-associated lymphoid tissue (MALT) lymphoma, particularly, the "speckled enhancement" on gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI.

Methods: The institutional review board approved this retrospective observational study and waived informed consent. Using our picture archiving and communication systems and electronic medical records, five patients histopathologically diagnosed as hepatic MALT lymphoma and clinically confirmed as primary lesions who had undergone dynamic contrast-enhanced (DCE)-CT and DCE-MRI with Gd-EOB-DTPA were identified from September 2009 to December 2020.

View Article and Find Full Text PDF

To characterize the brain responses to traumatic memories in post-traumatic stress disorder (PTSD), we conducted task-employed functional magnetic resonance imaging and, in the process, devised a simple but innovative approach-correlation computation between task conditions. A script-driven imagery task was used to compare the responses with a script of the patients' own traumatic memories and with that of tooth brushing as a daily activity and to evaluate how eye movement desensitization and reprocessing (EMDR), an established therapy for PTSD, resolved the alterations in patients. Nine patients with PTSD (seven females, aged 27-50 years) and nine age- and gender-matched healthy controls participated in this study.

View Article and Find Full Text PDF

Respiratory-gated four-dimensional phase-contrast vastly undersampled isotropic projection reconstruction (4D PC-VIPR) is magnetic resonance (MR) imaging technique that enables analysis of vascular morphology and hemodynamics in a single examination using cardiac phase resolved 3D phase-contrast magnetic resonance imaging. The present study aimed to assess the usefulness of 4D PC-VIPR for the superior mesenteric artery (SMA) flowmetry before and after flow increase was induced by the herbal medicine Daikenchuto (TJ-100) by comparing it with Doppler ultrasound (DUS) as a current standard. Twenty healthy volunteers were enrolled in this prospective single-arm study.

View Article and Find Full Text PDF
Article Synopsis
  • Diagnosis and severity assessments of portosystemic shunts (PSSs) are crucial as they can lead to serious liver complications, but can be effectively treated with shunt embolization.
  • Traditional imaging techniques like computed tomography and ultrasound mainly assess morphology and blood flow, respectively.
  • The study utilized advanced 4D-flow MRI to evaluate blood flow changes in two cases before and after shunt embolization, showing improvements in blood flow patterns, highlighting its utility alongside Doppler ultrasonography for better assessment of PSSs.
View Article and Find Full Text PDF

Purpose: Non-calcified cholesterol stones that are small in size are hard to be depicted on CT or magnetic resonance cholangiopancreatography. This institutional review board (IRB)-approved retrospective in vitro study aims to characterize contrast behaviors of 3 main components of the gallstones, i.e.

View Article and Find Full Text PDF

Background: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool.

View Article and Find Full Text PDF

We present a case of a patient who underwent portal vein (PV) stenting for PV stenosis after a living-donor liver transplantation. A pretreatment 3D cine phase-contrast (4D-flow) MRI showed decreased, though hepatopetal, blood flow in the PV. After stenting, 4D-flow MRI confirmed an improvement in PV flow, with a more homogeneous flow distribution to each hepatic segment.

View Article and Find Full Text PDF
4D Flow when and how?

Radiol Med

September 2020

4D Flow is an emerging MR technique enabling three-dimensional and cardiac phase-resolved flowmetry with ECG-gated phase-contrast MRI that increased the speed of data acquisitions, accuracy and robustness. The method is promoting researches in areas that have not been fully addressed before in the cardiovascular system, such as flowmetry of the bloodstream across the valves, within the heart chambers, complexed flow dynamics such as vortex, helical or retrograde. Wall shear stress and other potential biomarkers derived from 4D Flow are known to be related to vascular wall diseases such as atherosclerosis.

View Article and Find Full Text PDF

Purpose: To characterize the non-laminar flow dynamics and resultant decreased wall shear stress (WSS) and high oscillatory shear index (OSI) of the infrarenal abdominal aortic dilatation, cardiac phase-resolved 3D phase-contrast MRI (4D-flow MRI) was performed.

Methods: The prospective single-arm study was approved by the Institutional Review Board and included 18 subjects (median 67.5 years) with the dilated infrarenal aorta (median diameter 35 mm).

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionokrdh2c3gp9sd2arrm5gchpcoku1smhg): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once