J Family Med Prim Care
December 2020
Duloxetine-induced hyponatraemia is a known adverse effect that can lead to potentially life-threatening complications. In addition, hypocortisolaemia is associated with the development of hyponatraemia. Here, we report a case of severe hyponatraemia rapidly presenting after duloxetine treatment in a patient with hypocortisolaemia.
View Article and Find Full Text PDFWe evaluated the biological effects of implant abutments made from ceria-stabilized zirconia/alumina nanocomposite (Ce-TZP/AlO) with surface roughness variations using human gingival fibroblasts (HGF-1) in the transmucosal region. Two types of titanium (Ti) and Ce-TZP/AlO disks with different surface roughness profiles were prepared (Ra0.9 and Ra0.
View Article and Find Full Text PDFA 47-year-old woman with diabetes treated with high-dose insulin was admitted to Mie University Hospital, Tsu, Japan, for screening of secondary diabetes mellitus and obesity. Laboratory tests and imaging studies were consistent with Cushing's disease (CD). The patient underwent trans-sphenoidal pituitary surgery.
View Article and Find Full Text PDFThis paper studied the surface quality (damage, morphology, and phase transformation) of yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) in CAD/CAM milling, and subsequent polishing, sintering and sandblasting processes applied in dental restorations. X-ray diffraction and scanning electron microscopy (SEM) were used to scan all processed surfaces to determine phase transformations and analyse surface damage morphology, respectively. The average surface roughness (R) and maximum roughness (R) for all processed surfaces were measured using desk-top SEM-assisted morphology analytical software.
View Article and Find Full Text PDFCase: A 64-year-old Japanese woman with diabetes mellitus was admitted for hypoglycemia. Her diabetes had been under good control with glimepiride, voglibose, exenatide, and metformin for a few years. Although overt proteinuria was observed, the serum creatinine values were within normal range during the routine outpatient follow-up.
View Article and Find Full Text PDFPurpose: Ceria-stabilized zirconia/alumina nanocomposite (Ce-TZP/A) has excellent fracture toughness and bending strength that could be useful for partial denture framework application. The aim of this study was to investigate the effects of three-dimensional (3D) geometry on the bending and fatigue properties of a model simulation of Ce-TZP/A clasps.
Materials And Methods: Half oval-shaped Ce-TZP/A rods were prepared in six 3D designs.
The aim of this study was to examine the compatibility of Ce-TZP/Al2O3 nanocomposite (CTA) frameworks and veneering porcelains using the Schwickerath crack initiation test and clarify the effects on debonding/crack initiation strength (DIS) of both surface pretreatment (include heat treatment) of the frameworks, type of veneering porcelain varying the coefficient of thermal expansion (CTE), and surface roughness of the frameworks. The surfaces of Ce-TZP/Al2O3 plates were mechanically treated and followed by post-heat treatment. The liner and body porcelains were built up and fired according to the manufacturer's instructions.
View Article and Find Full Text PDFThis study aimed to develop a dental investment for titanium casting. ZrO(2) and Al(2)O(3) were selected as refractory materials to prepare three investments (Codes: A-C) according to the quantity of Zr. Al(2)O(3) cement was used as a binder at a ratio of 15%, they were mixed with special mixing liquid.
View Article and Find Full Text PDFBackground: It is difficult to study the mechanisms of the metabolic syndrome in humans due to the heterogeneous genetic background and lifestyle. The present study investigated changes in the gene and protein profiles in an animal model of the metabolic syndrome to identify the molecular targets associated with the pathogenesis and progression of obesity related to the metabolic syndrome.
Methods: We extracted mRNAs and proteins from the liver tissues of 6- and 25-week-old spontaneously hypertensive/NIH -corpulent rat SHR/NDmcr-cp (CP), SHR/Lean (Lean) and Wistar Kyoto rats (WKY) and performed microarray analysis and two-dimensional difference in gel electrophoresis (2D-DIGE) linked to a matrix-assisted laser desorption ionization time-of-flight tandem mass spectrometry (MALDI-TOF/TOF MS).
In this study, different glasses were investigated to improve reusable investments. Borosilicate glass (BSG) powder and soda-lime glass (SLG) powder were prepared by milling broken beakers and microscope slides, respectively, and used in experimental investments (I-BSG, I-SLG) by blending glass powder (10 wt%) with cristobalite (90 wt%). Some properties and casting fits were evaluated with commercial gypsum-bonded investment as the control.
View Article and Find Full Text PDFA novel method was developed to fabricate all-ceramic restorations which comprised CAD/CAM-fabricated machinable ceramic bonded to CAD/CAM-fabricated zirconia framework using resin cement. The feasibility of this fabrication method was assessed in this study by investigating the bonding strength of a machinable ceramic to zirconia. A machinable ceramic was bonded to a zirconia plate using three kinds of resin cements: ResiCem (RE), Panavia (PA), and Multilink (ML).
View Article and Find Full Text PDFThe aim of the present study was to evaluate the bonding durability of resin-based luting cement to partially stabilized tetragonal zirconia (Y-TZP) achieved by combination treatment of tribochemical (TBC) treatment and two different phosphate acid ester monomers. Two phosphate acid ester monomers (EP: Epricord opaque primer, AZ: AZ primer) were applied to each surface modification followed by application of resin-based luting cement (Rely-X ARC). Bonding specimens were placed in deionized water at 37 degrees C and stored for 24 h.
View Article and Find Full Text PDFIn this article, we review the recent history of the development of dental CAD/CAM systems for the fabrication of crowns and fixed partial dentures (FPDs), based on our 20 years of experience in this field. The current status of commercial dental CAD/CAM systems developed around the world is evaluated, with particular focus on the field of ceramic crowns and FPDs. Finally, we discuss the future perspectives applicable to dental CAD/CAM.
View Article and Find Full Text PDFThe aim of this study was to investigate the effect of post-machining sintering on marginal and internal fit of CAD/CAM-fabricated zirconia frameworks. Single crown copings (A: abutment), three-unit bridge frameworks (APA, P: pontic), four-unit bridge frameworks (APPA), and five-unit bridge frameworks (A1P1A2P2A3) were fabricated with raw-stage zirconia blanks using a commercial CAD/CAM system (KATANA, Noritake Dental Supply Co. Ltd.
View Article and Find Full Text PDFTo increase the bond strength of CAD/CAM-fabricated, leucite-reinforced glass ceramics with a resin cement, the effects of the following were investigated: surface modification by tribochemical (TBC) treatment, followed by combined application of a silane coupling agent and a functional monomer as a primer. Bond strength was evaluated by a shear bond test. It was found that a silane coupling agent was useful for all the surfaces, particularly for the TBC-treated surface.
View Article and Find Full Text PDFThis study aimed to develop reusable dental investments. SiO2 and MgO were selected as refractory materials to prepare three types of investment (coded as 60S-40M, 80S-20M, 100S) with 40, 20, and 0 wt% of MgO. Each type of investment was reused twice.
View Article and Find Full Text PDFObjectives: For titanium casting, most commercial investments for titanium recommend casting at a low mold temperature to reduce oxidation. However, the thermal expansion values of the molds at low casting temperatures may be insufficient. The purpose of the current study was to investigate the possibility of obtaining accurate titanium crown casts using wax pattern fabricated by a CAD/CAM system with a non-expanded mold.
View Article and Find Full Text PDFThis study examined fracture toughness (KIC) measurements obtained using the indentation fracture (IF) method with a view to improving their reliability. The KIC values of five dental ceramics were measured using the IF method with five different formulas, and the single-edge precracked beam (SEPB) method was used as a control. The elastic moduli of the dental ceramics were evaluated by dynamic hardness test.
View Article and Find Full Text PDFThe purpose of this study was to investigate the effect of repeated machining up to 51 times using the same diamond bur on machining accuracy of inner and outer surfaces of CAD/CAM (computer-aided designing and computer-aided manufacturing) machined ceramic crowns. The surface topography of machined crowns was examined using photographs. It was found that machining accuracy was not affected by the number of machining times.
View Article and Find Full Text PDFIndustrial waste is on the increase, resulting in severe environmental contamination. Against this background, this study sought to investigate the possibility of recycling used phosphate-bonded investments. Commercial phosphate-bonded investment was mixed and heated according to manufacturer's instructions, then powdered with a ball mill machine to be used as recycled investment (Code: R).
View Article and Find Full Text PDFThe purpose of this study was to evaluate the durability of tungsten carbide burs for the fabrication of titanium crowns using two dental CAD/CAM systems (DECSY, Digital Process, Japan and Cadim, Advance, Japan). A tungsten carbide bur in each system was examined and used without fracture to fabricate 51 titanium crowns. For both systems tiny chips were found on the bur blade at the 11th machining.
View Article and Find Full Text PDF