Statement Of Problem: The effects of the internal contact surfaces of dental implants on screw loosening have yet to be investigated.
Purpose: The purpose of this 3-dimensional finite element analysis (FEA) study was to evaluate and compare the mechanical effects of the abutment implant angle (θ), the abutment screw head diameter (D), and the abutment screw length (L) on screw loosening.
Material And Methods: A total of 27 models presenting various mechanical scenarios were built by using combinations of 3 different θ (30 degrees, 45 degrees, and 60 degrees), D (2.
Using a real bone is very important to find correct results for the biomechanical studies. However, it is very difficult to find the real bone and sometimes artificial bone models can be preferred instead of real bone. The aim of this study is to obtain an easy-to-manufacture, easy-to-customize and inexpensive method the artificial first metatarsal bone model that is similar material properties with the real bone.
View Article and Find Full Text PDFAustralas Phys Eng Sci Med
December 2019
Cemented and cementless hip prostheses are used in total hip replacement surgery. Short, medium and long term success rates of these hip prostheses are controversial in the literature. Traditional cemented and cementless hip prostheses have advantages and disadvantages affecting the success of the implantation process.
View Article and Find Full Text PDFAustralas Phys Eng Sci Med
June 2017
This study presents the numerical analysis of stem fixation in hip surgery using with/without cement methods since the use of cement is still controversial based on the clinical studies in the literature. Many different factors such as stress shielding, aseptic loosening, material properties of the stem, surgeon experiences etc. play an important role in the failure of the stem fixations.
View Article and Find Full Text PDFIn this study, the cut-out risk of Dynamic Hip Screw (DHS) was investigated in nine different positions of the lag screw for two fracture types by using Finite Element Analysis (FEA). Two types of fractures (31-A1.1 and A2.
View Article and Find Full Text PDFThis study addresses the results of the experimental measurements for the contact surface areas and contact pressure distributions of a dysplastic hip joint. The hip joint consists of pelvis, proximal femur and artificial cartilages for both acetabulum and femoral head. The dysplastic hip joint is modeled in three dimensional (3D) form using the computerized tomography (CT) images obtained in vivo of an adult female patient.
View Article and Find Full Text PDFActa Bioeng Biomech
September 2014
Blount's disease, or tibia vara, is the most common cause of pathologic genu varum in children and adolescents. Changes in the loading of knee structures such as tibial articular cartilage, menisci and subcondral bone are well documented in case of genu varum. But the mechanical effects of this condition on foot bones are still questionable.
View Article and Find Full Text PDFBackground: Proximal tibial open wedge osteotomy (PTO) is a corrective operation used in the surgery of lower extremities and is applied to patients with varus deformities for sufficient correction. The aim of the study was to evaluate whether the PTO can achieve decreased stress-bearing on the tibia and tarsal bones in addition to correcting the mechanical axis of the lower limb in patients with tibia vara.
Methods: Three-dimensional (3D) solid modelling of the lower extremity was carried out using computed tomography (CT) and magnetic resonance (MR)-containing images of all of the bony elements and non-bony structures.