An important method that coal-fired power plants use to realise low-cost zero discharge of desulfurisation wastewater (FGD wastewater) is to utilise wet slag removal systems. However, the high Cl content of FGD wastewater in wet slag removal systems causes environmental damage. In this study, the corrosion behaviour of the inner guide wheel material, 20CrMnTi, was studied using dynamic weight loss and electrochemical methods.
View Article and Find Full Text PDFAn effective strategy for achieving cost-effective and environmentally friendly desulfurization wastewater in coal-fired power plants involves the incorporation of desulfurization wastewater into the slag water system. The objective of this study was to analyze the corrosion behavior of Q235-A slag-picker shell material upon the introduction of FGD wastewater into the slag water system. The dynamic weight loss method, electrochemical testing method and microscopic phase characterization were employed to investigate the impact of varying chloride ion concentrations (ranging from 1000 mg/L to 30,000 mg/L) of flue gas desulfurization wastewater (FGD wastewater) on the corrosion of Q235-A slag-picker shell material.
View Article and Find Full Text PDF