Background: The goal of this longitudinal analysis of anatomic total shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) utilization from 2007 to 2021 is to quantify changes in clinical outcomes, cost, and value, resulting from the introduction and adoption of new shoulder arthroplasty (SA) technologies.
Methods: We analyzed an international database of a single SA prosthesis (Equinoxe; Exactech, Inc.; Gainesville, FL, USA) for all clinical sites that have continuously enrolled cases from 2007 to 2021 to compare changes in primary aTSA and primary rTSA utilization and outcomes across 3, 5-year cohorts based upon the date of implantation.
Objectives: To evaluate tuberosity union rate and clinical outcome after 3- and 4-part proximal humerus fractures in the elderly.
Design: Retrospective, multicenter database cohort study.
Setting: Level I and Level II trauma centers.
Introduction: Indications for anatomic (aTSA) and reverse (rTSA) total shoulder arthroplasty are well defined and dependent on the function of the rotator cuff; however, indications for rTSA have gradually extended to complex fractures, revisions, and primary arthritis in very elderly patients. The risk of secondary rupture of a weakened or degenerative rotator cuff is difficult to assess and can lead the orthopaedic surgeon to hesitate between aTSA or rTSA. It, therefore, seems appropriate to compare these two types of prostheses in terms of pain, functional, clinical outcome metric scores, and complications, despite suspected differences between populations and the respective diseases.
View Article and Find Full Text PDFIntroduction: The rate of clinical improvement has never been studied after anatomic (aTSA) and reverse (rTSA) total shoulder arthroplasty. This study quantifies the rate of improvement after aTSA and rTSA using five different scoring metrics for 1,641 patients.
Methods: We evaluated 1,641 (69 ± 9.
Purpose: The purpose of this study is to validate a reverse shoulder computer impingement model and quantify the impact of implant position on scapular impingement by comparing it to that of a radiographic analysis of 256 patients who received the same prosthesis and were followed postoperatively for an average of 22.2 months.
Methods: A geometric computer analysis quantified anterior and posterior scapular impingement as the humerus was internally and externally rotated at varying levels of abduction and adduction relative to a fixed scapula at defined glenoid implant positions.
Bull Hosp Jt Dis (2013)
September 2014
Unlabelled: Worldwide, the usage of both anatomic total shoulder arthroplasty (aTSA) and reverse total shoulder arthro- plasty (rTSA) has increased significantly due, in part, to the predictability of acceptable outcomes achieved with each prosthesis type. This study quantifies outcomes using five different metrics and compares results using one platform total shoulder arthroplasty system that utilizes the same humeral component and instrumentation to perform both aTSA or rTSA.
Methods: 200 patients were treated by two orthopaedic surgeons using either aTSA or rTSA.