Publications by authors named "Yana Zlateva"

Purpose: In this study, we evaluate and compare single isocenter multiple target VMAT (SIMT) and Conformal Arc Informed VMAT (CAVMAT) radiosurgery's sensitivity to uncertainties in dosimetric leaf gap (DLG) and treatment delivery. CAVMAT is a novel planning technique that uses multiple target conformal arcs as the starting point for limited inverse VMAT optimization.

Methods: All VMAT and CAVMAT plans were recalculated with DLG values of 0.

View Article and Find Full Text PDF

AAPM TG-218 provides recommendations for standard IMRT pre-treatment QA without giving specifics for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). In light of this, our purpose is to report our experience with applying TG-218 recommendations to a large multicenter clinical SRS and SBRT program for a range of diverse clinical pre-treatment QA systems. Pre-treatment QA systems included Delta4 (Scandidos), Portal Dosimetry (Varian Medical Systems), ArcCHECK (SunNuclear), and SRS MapCHECK (SunNuclear).

View Article and Find Full Text PDF

Purpose: Previous work presented and validated in-water Cherenkov emission (CE)-based radiotherapy dosimetry. Condensed history Monte Carlo (MC)-calculated electron beam CE-to-dose conversion with <4π CE detection, however, could exhibit step-size dependence. This work presents a physics update and numerical study of this step-size dependence in photon and electron beams, elucidates the CE generation physics, and guides further research.

View Article and Find Full Text PDF

Purpose: Cherenkov emission (CE)-based external beam dosimetry is envisioned to involve the detection of CE directly in water with placement of a high-resolution detector out of the field, avoiding perturbations encountered with traditional dosimeters. In this work, we lay out the groundwork for its implementation in the clinic and motivate CE-based dosimeter design efforts. To that end, we examine a formalism for broad-beam in-water CE-based dosimetry of external radiotherapy beams, design and test a Monte Carlo (MC) simulation framework for the calculation of CE-to-dose conversion factors used by the formalism, and demonstrate the experimental feasibility of this method.

View Article and Find Full Text PDF

Purpose: Cherenkov emission (CE) is ubiquitous in external radiotherapy. It is also unique in that it carries the promise of 3D, micrometer-resolution, perturbation-free, in-water dosimetry with a beam quality-independent detector response calibration. Our aim is to bring CE-based dosimetry into the clinic and we motivate this here with electron beams.

View Article and Find Full Text PDF