Publications by authors named "Yakoumakis E"

The aim of the present study is the estimation of radiation burden during liver chemoembolisation procedures. Organ dose and effective dose conversion factors, normalised to dose-area product (DAP), were estimated for chemoembolisation procedures using a Monte Carlo transport code in conjunction with an adult mathematical phantom. Exposure data from 32 patients were used to determine the exposure projections for the simulations.

View Article and Find Full Text PDF

Purpose: To estimate the mean glandular dose of contrast enhanced digital mammography, using the EGSnrc Monte Carlo code and female adult voxel phantom.

Methods: Automatic exposure control of full field digital mammography system was used for the selection of the X-ray spectrum and the exposure settings for dual energy imaging. Measurements of the air-kerma and of the half value layers were performed and a Monte Carlo simulation of the digital mammography system was used to compute the mean glandular dose, for breast phantoms of various thicknesses, glandularities and for different X-ray spectra (low and high energy).

View Article and Find Full Text PDF

The purpose of the present study was to present the national diagnostic reference levels (DRL) established for panoramic dental examinations in Greece. The establishment of DRL, as a tool for the optimisation of radiological procedures, is a requirement of national regulations. Measurements performed by the Greek Atomic Energy Commission on 90 panoramic systems have been used for the derivation of DRL values.

View Article and Find Full Text PDF

Mammography is a standard procedure that facilitates breast cancer detection. Initial results of contrast-enhanced digital mammography (CEDM) are promising. The purpose of this study is to assess the CEDM radiation dose using a Monte Carlo code.

View Article and Find Full Text PDF

Radiation protection and estimation of the radiological risk in paediatric radiology is essential due to children's significant radiosensitivity and their greater overall health risk. The purpose of this study was to estimate the organ and effective doses of paediatric patients undergoing barium meal (BM) examinations and also to evaluate the assessment of radiation Risk of Exposure Induced cancer Death (REID) to paediatric patients undergoing BM examinations. During the BM studies, fluoroscopy and multiple radiographs are involved.

View Article and Find Full Text PDF

Objectives: To estimate the organ equivalent doses and the effective doses (E) in patient undergoing percutaneous transhepatic biliary drainage (PTBD) examinations, using the MCNP5 and PCXMC2 Monte Carlo-based codes.

Methods: The purpose of this study is to estimate the organ doses to patients undergoing PTBD examinations by clinical measurements and Monte Carlo simulation. Dose area products (DAP) values were assessed during examination of 43 patients undergoing PTBD examination separated into groups based on the gender and the dimensions and location of the beam.

View Article and Find Full Text PDF

The estimation of the radiological risk in the case of children is of particular importance due to their enhanced radiosensitivity when compared with that of adult patients. The purpose of this study is to estimate the organ and effective doses of paediatric patients undergoing micturating cystourethrography examinations. Since direct measurements of the dose in each organ are very difficult, dose-area products of 90 patients undergoing cystourethrography examinations were recorded and used with two Monte Carlo codes, MCNP5 and PCXMC2.

View Article and Find Full Text PDF

Diagnostic reference levels (DRLs) is a tool for the optimisation of radiological procedures. Establishment of a DRL is a requirement of national regulations. Measurements performed by the Greek Atomic Energy Commission on 529 dental intraoral radiographic facilities have been used in order to define DRLs for digital and film imaging modalities, taking into account the region of the mouth to be imaged.

View Article and Find Full Text PDF

The fact that children do undergo computed tomography (CT) examinations similar to those for adults adults has been a research issue, especially since the former are exposed to greater risk levels (developing stochastic late effects, such as cancer) due to their increased radiosensitivity compared to the latter. In a previous research paper (), the values of dose levels were recorded, analyzed, and compared with the reference values for groups of 0, 1, 5 and 10 y-old children for the regions of head, chest, and abdomen. In this paper, the same age group has been considered for measuring dose levels of the pelvic region.

View Article and Find Full Text PDF

Background: Children diagnosed with congenital heart disease often undergo cardiac catheterization for their treatment, which involves the use of ionizing radiation and therefore a risk of radiation-induced cancer.

Objective: The purpose of this study was to calculate the effective and equivalent organ doses (H(T)) in those children and estimate the risk of exposure-induced death.

Materials And Methods: Fifty-three children were divided into three groups: atrial septal defect (ASD), ventricular septal defect (VSD) and patent ductus arteriosus (PDA).

View Article and Find Full Text PDF

Lung brachytherapy using high-dose rate (192)Ir technique is a well-established technique of radiation therapy. However, many commercial treatment planning systems do not have the ability to consider the inhomogeneity of lung in relation to normal tissue. Under such circumstances dose calculations for tissues and organs at risk close to the target are inaccurate.

View Article and Find Full Text PDF

Patient dose measurements of local entrance dose to the skin have been carried out using radiochromic film (Gafchromic XR-RV2) in a sample of interventional procedures. The major aim of the work was to measure patient entrance dose from such examinations using Gafchromic XR-RV2. Forty-five various interventional procedures (including nefrostomies and urinary stenting, biliary stenting and percutaneous transhepatic biliary drainage (PTBD) and aorta stent grafting) were evaluated.

View Article and Find Full Text PDF

External beam radiation therapy (RT) is often offered to breast cancer patients after surgical mastectomy followed by breast reconstruction with silicone implants. In some cases, the RT is administered while the patient is still implanted with a temporary tissue expander including a high-density metallic port, which is expected to affect the planned dose distribution. This work uses Monte Carlo (MC) simulation in order to evaluate the aforementioned effect when the McGhan Style 133 Tissue Expander with the Magna-Site injection port is used.

View Article and Find Full Text PDF

Organ doses are important quantities in assessing the radiation risk. In the case of children, estimation of this risk is of particular concern due to their significant radiosensitivity and the greater health detriment. The purpose of this study is to estimate the organ doses to paediatric patients undergoing barium meal and micturating cystourethrography examinations by clinical measurements and Monte Carlo simulation.

View Article and Find Full Text PDF

Computed tomography provides high-resolution imaging of the human body. However, it contributes mainly to the doses on the population. Additionally, the fact that children are two to three times more sensitive to the x rays compared to the adults results in the increased need of taking action for the reduction of the dose regarding the computed tomography examinations.

View Article and Find Full Text PDF

Entrance surface radiation doses were measured with thermoluminescent dosimeters for 98 children who were referred to a cardiology department for the diagnosis or the treatment of a congenital heart disease. Additionally, all the radiographic parameters were recorded and Monte Carlo simulations were performed for the estimation of entrance surface dose to effective dose conversion factors, in order to further calculate the effective dose for each child. For diagnostic catheterisations the values ranged from 0.

View Article and Find Full Text PDF

Radiation exposure was investigated for children undergoing various common radiographies in three dedicated pediatric hospitals in Greece. Kerma in air at the entrance of the beam (Ka,e) was measured with thermoluminescent dosimeters. Ka,e values ranged from 0.

View Article and Find Full Text PDF

Anorectal melanoma (AM) is a rare disease and few guidelines have been established regarding its therapeutic management. Wide local excision, or less frequently, abdominoperineal resection is the treatment of choice. We present a female patient with an excised AM who was submitted to our Nuclear Medicine department for sentinel lymph node (SLN) mapping of the area.

View Article and Find Full Text PDF

In this study, the entrance surface dose (ESD) and the respective effective dose (E) were determined for paediatric patients undergoing various common radiological examinations in two dedicated paediatric hospitals. Measurements of ESD were carried out in 289 examinations using thermoluminescent dosemeters. The patients were categorised according to their age and the mean ESD and E values were determined for each examination and age category.

View Article and Find Full Text PDF

Seeking to assess the radiation risk associated with radiological examinations in neonatal intensive care units, thermo-luminescence dosimetry was used for the measurement of entrance surface dose (ESD) in 44 AP chest and 28 AP combined chest-abdominal exposures of a sample of 60 neonates. The mean values of ESD were found to be equal to 44 +/- 16 microGy and 43 +/- 19 microGy, respectively. The MCNP-4C2 code with a mathematical phantom simulating a neonate and appropriate x-ray energy spectra were employed for the simulation of the AP chest and AP combined chest-abdominal exposures.

View Article and Find Full Text PDF

The objective of the study was to derive a mathematical method for calculating the entrance surface dose (ESD) from exposure factors for all tube potentials used in clinical practice and to compare the calculated ESDs (ESD(C)) with those measured (ESD(TLD)) using thermoluminescent dosemeters (TLDs). The exposure parameters of 43 patients who underwent (a) posteroanterior (PA) and lateral (LAT) chest examination (13 patients), (b) supine abdomen (10 patients), (c) erectus abdomen (10 patients), or (d) urinary tract examination (10 patients) were recorded. Patient ESD was directly measured by TLDs and calculated from exposure factors.

View Article and Find Full Text PDF

The aim of this study was to determine the radiation doses to patients during extracorporeal shock wave lithotripsy (ESWL) and compare them with the available bibliographical data. In this method localization of the renal stones is attained by the use of fluoroscopy, and thus ESWL is included among those medical practices associated with patient radiation exposure. The entrance surface dose was measured using 3-4 thermoluminescent dosimeters positioned on the patients' backs at the entrance surfaces of the two x-ray beams for 50 ESWL procedures.

View Article and Find Full Text PDF

In this study the effect of different mammographic screen-film combinations on image quality and breast dose, and the correlation between the various image quality parameters, breast dose and the sensitometric parameters of a film were investigated. Three Agfa (MR5-II, HDR, HT), two Kodak (Min-R M, Min-R 2000), one Fuji (AD-M), one Konica (CM-H) and one Ferrania (HM plus) single emulsion mammographic films were combined with three intensifying screens (Agfa HDS, Kodak Min-R 2190 and Fuji AD-MA). The film characteristics were determined by sensitometry, while the image quality and the dose to the breast of the resulting 24 screen-film combinations were assessed using a mammography quality control phantom.

View Article and Find Full Text PDF

The purpose of this study was to estimate the radiation exposure of children, during cardiac catheterisations for the diagnosis or treatment of congenital heart disease. Radiation doses were estimated for 45 children aged from 1 d to 13 y old. Thermoluminescent dosemeters (TLDs) were used to estimate the posterior entrance dose (DP), the lateral entrance dose (DLAT), the thyroid dose and the gonads dose.

View Article and Find Full Text PDF
Article Synopsis
  • The study assessed patient radiation doses during digital subtraction angiography (DSA) by analyzing fluoroscopy time, dose-area product (DAP), and entrance surface air kerma (ESAK) from 263 DSA exams categorized into seven types.
  • Median DAP values varied across categories, with the lowest for celiac trunk and the highest for superselective DSA of hepatic and splenic arteries.
  • ESAK values were generally below the 2 Gy limit for erythema, indicating low risk of skin damage, and DAP results were consistent with some previously published data while lacking references for a few categories.
View Article and Find Full Text PDF