Publications by authors named "Y H Mugahed Amran"

The objective of this research was to determine the durability of an engineered cementitious composite (ECC) incorporating crumb rubber (CR) and graphene oxide (GO) with respect to resistance to acid and sulphate attacks. To obtain the mix designs used for this study, response surface methodology (RSM) was utilized, which yielded the composition of 13 mixes containing two variables (crumb rubber and graphene oxide). The crumb rubber had a percentage range of 0-10%, whereas the graphene oxide was tested in the range of 0.

View Article and Find Full Text PDF

The concrete-filled double skin steel tube (CFDST) is a more viable option compared to a concrete-filled steel tube (CFST) due to consisting a hollow section, while degradation is enhanced simply by using carbon fiber-reinforced polymer (CFRP). Hence, the stabilization of a concrete's ductile strength needs high- performance fiber-reinforced cementitious conmposite. This study investigates the behavior of high-performance fiber-reinforced cementitious composite-filled double-skin steel tube (HPCFDST) beams strengthened longitudinally with various layers, lengths, and configurtion of CFRP sheets.

View Article and Find Full Text PDF

Engineered cementitious composite (ECC) was discovered as a new substitute of conventional concrete as it provides better results in terms of tensile strain, reaching beyond 3%. From then, more studies were done to partially replace crumb rubber with sand to achieve a more sustainable and eco-friendlier composite from the original ECC. However, the elastic modulus of ECC was noticeably degraded.

View Article and Find Full Text PDF

Deep beams are more susceptible to shear failure, and therefore reparation is a crucial for structural reinforcements. Shear failure is structural concrete failure in nature. It generally occurs without warning; however, it is acceptable for the beam to fail in bending but not in shear.

View Article and Find Full Text PDF

Objectives: The perceptions of family-planning (FP) acceptors regarding contraception influence the reasons for which they choose to switch their method of contraception. The objective of this study was to analyze the perceptions of contraception and rationales for switching contraceptive methods among female FP acceptors in West Nusa Tenggara, Indonesia.

Methods: This study involved the analysis of secondary data from the Improve Contraceptive Method Mix study, which was conducted in 2013 by the Center for Health Research, University of Indonesia.

View Article and Find Full Text PDF